Common use of CULVERT INSTALLATION Clause in Contracts

CULVERT INSTALLATION. Culvert installation must be in accordance with the CULVERT AND DRAINAGE SPECIFICATION DETAIL. Corrugated Polyethylene pipe must be installed in a manner consistent with the manufacturer’s recommendations. Culverts shall be banded using lengths of no less than 10 feet, and no more than one length less than 15 feet.

Appears in 3 contracts

Samples: Sale, State U1n4less, www.dnr.wa.gov

AutoNDA by SimpleDocs

CULVERT INSTALLATION. Culvert installation must be in accordance with the CULVERT AND DRAINAGE SPECIFICATION DETAIL. DETAIL and the Corrugated Polyethylene pipe must be installed in a manner consistent with the manufacturerPipe Association’s recommendations“Recommended Installation Practices for Corrugated Polyethylene Pipe and Fittings”. Culverts over 15 inches diameter shall be banded using lengths of no less than 10 feet, and no more than one length less than 15 16 feet. Shorter section of banded culvert shall be installed at the inlet end.

Appears in 2 contracts

Samples: State Unless Otherwise Noted, www.dnr.wa.gov

CULVERT INSTALLATION. Culvert installation must be in accordance with the CULVERT AND DRAINAGE SPECIFICATION DETAILDETAIL and the Corrugated Polyethylene Pipe Association’s “Recommended Installation Practices for Corrugated Polyethylene Pipe and Fittings”. Corrugated Polyethylene pipe must be installed in a manner consistent with the manufacturer’s recommendations. Culverts shall be banded using lengths of no less than 10 feet, and no more than one length less than 15 16 feet. Shorter sections of banded culvert shall be installed at the inlet end.

Appears in 2 contracts

Samples: www.dnr.wa.gov, www.dnr.wa.gov

CULVERT INSTALLATION. Culvert installation must be in accordance with the CULVERT AND DRAINAGE SPECIFICATION DETAILDETAIL and the Corrugated Polyethylene Pipe Association’s “Recommended Installation Practices for Corrugated Polyethylene Pipe and Fittings”. Corrugated Polyethylene pipe must be installed in a manner consistent with the manufacturer’s recommendations. Culverts over 18 inches diameter shall be banded using lengths of no less than 10 feet, and no more than one length less than 15 16 feet.

Appears in 1 contract

Samples: State Unless Otherwise Noted

AutoNDA by SimpleDocs

CULVERT INSTALLATION. Culvert installation must be in accordance with the CULVERT AND DRAINAGE SPECIFICATION DETAILDETAIL and the Corrugated Polyethylene Pipe Association’s “Recommended Installation Practices for Corrugated Polyethylene Pipe and Fittings”. Corrugated Polyethylene pipe must be installed in a manner consistent with the manufacturer’s recommendations. Culverts over 15 inches diameter shall be banded using lengths of no less than 10 feet, and no more than one length less than 15 16 feet. Shorter section of banded culvert shall be installed at the inlet end.

Appears in 1 contract

Samples: www.dnr.wa.gov