Building Sections. Dimensions: Vertical dimensions relating to floor, ceiling, roof, top of steel Provide grid lines and cross reference to floor plans Materials: Note and indicate material as well as listed fire rated assemblies ❑ G. Reflected Ceiling Plan Provide ceiling construction. Show ceiling breaks, or change in height Show ceiling pattern, diffusers, light fixtures, exit signage and access panels ❑ H. Enlarged Floor Plan(s) Toilet Room Plans: Plumbing fixtures, stall layout, and handicap accessibility Verify plumbing fixture count with code requirements. Kitchens: Kitchen equipment layout ❑ I. Interior Elevations Toilet Room Elevations: Plumbing fixture heights and handicap accessibility Indicate wall finish materials ❑ J. Schedules Room Finish Schedule: Show interior finishes Door Schedule: Door types, sizes and fire rating, door hardware Window Schedule: Window types, frames, labels, glazing and sizes ❑ K. Architectural Details Stairs: Riser and tread dimensions, headroom clearance, and handrail details and attachment details Guardrails: Height and distance between intermediate rails and attachment details Ramps: Slope and length and handrails Wall Types: Fire rated construction, corridor walls, shaft walls, area separation walls, occupancy separation walls. Indicate listed assemblies for fire rated construction. Specify fire penetration sealants at rated walls.
Appears in 1 contract
Sources: Architect/Engineer Agreement
Building Sections. Dimensions: Vertical dimensions relating to floor, ceiling, roof, top of steel Provide grid lines and cross reference to floor plans Materials: Note and indicate material as well as listed fire rated assemblies ❑ G. Reflected Ceiling Plan Provide ceiling construction. Show ceiling breaks, or change in height Show ceiling pattern, diffusers, light fixtures, exit signage and access panels ❑ H. Enlarged Floor Plan(s) Toilet Room Plans: Plumbing fixtures, stall layout, and handicap accessibility Verify plumbing fixture count with code requirements. Kitchens: Kitchen equipment layout ❑ I. Interior Elevations Toilet Room Elevations: Plumbing fixture heights and handicap accessibility Indicate wall finish materials ❑ J. Schedules ▇. ▇▇▇▇▇▇▇▇▇ Room Finish Schedule: Show interior finishes Door Schedule: Door types, sizes and fire rating, door hardware Window Schedule: Window types, frames, labels, glazing and sizes ❑ K. Architectural Details Stairs: Riser and tread dimensions, headroom clearance, and handrail details and attachment details Guardrails: Height and distance between intermediate rails and attachment details Ramps: Slope and length and handrails Wall Types: Fire rated construction, corridor walls, shaft walls, area separation walls, occupancy separation walls. Indicate listed assemblies for fire rated construction. Specify fire penetration sealants at rated walls. L. Structural Notes Live Loads: Floors, stairs, corridors, roof, snow, earthquake and wind Dead Loads: Material weight, mechanical and electrical weight, wet-pipe or dry-pipe fire sprinkler system, and soil bearing pressure Material Strength: Concrete, masonry, steel and wood Foundation design based on Soils Report. Provide one (1) copy of the Soils/Geotechnical Report.
Appears in 1 contract
Sources: Architect/Engineer Agreement