Blockwiring. The specifications for the Blockwiring are: (a) Physical Characteristics: two wire copper cable connection for voice grade application (b) Bandwidth: 300 to 3400Hz (measured at 3dB below maximum signal response) (c) Signal Attenuation: nominal 1.7dB per km at 1600Hz (d) Typical Loop Resistance: 300Ω: maximum (e) Insulation Resistance to Earth: 250K: minimum (f) Circuit Random Noise: -45dBmp maximum (g) DC continuity for supporting basic DC signaling required for operation of basic voice telephony
Appears in 3 contracts
Sources: Blockwiring Agreement, Blockwiring Agreement, Blockwiring Agreement