Abnormal voltage test. The solenoid valve is connected to a variable DC voltage source. The solenoid valve is operated as follows: (i) An equilibrium (steady state temperature) hold is established for at least one hour at ≥ 1.5 times the rated voltage; (ii) The voltage is increased to ≥ 2 times the rated voltage or 60 volts, whichever is less, and held for at least one minute; (iii) Any failure shall not result in external valve leakage in accordance with Annex 4, paragraph 2.2., open valve or other unsafe conditions such as smoke, fire or melting.
Appears in 3 contracts
Sources: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles