Common use of SERVICE Clause in Contracts

SERVICE. The setting display is reserved to Service operations. ► Press MENU , with UP e DOWN buttons select 07 SETTING, press ENTER scroll the submenu items with the UP and DOWN buttons: SETTING 01 SERVICE SETTING 02 LANGUAGE (see par 9.2.3) SETTING 03 CLOCK SETTING (see par 9.2.4) SETTING 04 IMPUT/OUTPUT with the UP and DOWN buttons select 01 SERVICE press ENTER a password is required to get access to service submenu. Select the password -19 through the UP and DOWN buttons and press ENTER Correct password: the first submenu is visualized Wrong password: get-out of the menu Scroll the submenu 01 SERVICE with the UP and DOWN buttons: ► SERVICE 01 TIMER - It records the compressor working hours ► SERVICE 02 DEFROST - It records duration of the last defrost operations ► SERVICE 03 OPEN DOOR - It records the door openings and their duration ► SERVICE 04 SETTINGS - Save parameters ► SERVICE 05 RESET MEMORY - Erase memorized data ► SERVICE 06 RESTORE -WARNING!: Complete deletion of all parameters and machine arrest It records the compressor working hours. Press the UP and DOWN buttons to visualize the following data: Compo On CompoOff 04m41s 07m36s Compressor turning on and off average time Compo On Compo On 24%day 49%hrs Daily and hourly percentage of running compressor Compo Frigo 02d21h 05d10h Day and hours of the operation of the compressor Day and hours of the operation of the fridge The meters cannot be deleted. Get back to Service Menu pressing MENU .

Appears in 2 contracts

Sources: Instruction and Maintenance Manual, Instruction and Maintenance Manual