Load Profile(s) definition

Load Profile(s). At least 8 channels. • End of Billing Data: 18 months. • Communication: Allow for GPRS (General Packet Radio Service) internal or external plugin module. • Meter must be provided together with a SABS approved PVC Type quality meter box. • The meter must be compatible for use on the utilities management system of the service provider. • Product life: Expectancy should be at least 15 years. • Product warranty: 12 months from date of installation. • The following National and International specifications apply: o SANS 1524-1(2014): Electricity payment systemsPart 1: Payment meters. o SANS 1799 (2015): Watt-hour meters – AC electronic meters for active energy. o SANS/IEC 62053-21(2003): Electricity metering equipment (ac.) – Particular Requirements - Part 21: Static meters for active energy (class 1). o SANS/IEC 62055-41: 1st Ed, (2007) Electricity Metering Payment Systems, Part 41 - Standard Transfer Specification (STS) – Application Layer protocol for one-way token carrier systems. o SANS/IEC 62055-51: 1st Ed, (2007) Electricity Metering Payment Systems, Part 51 - Standard Transfer Specification (STS) - Physical Layer Protocol for one-way numeric and magnetic card token carriers. o SANS/IEC 62055-52: Ed 1, (2009) Electricity Metering Payment Systems, Part 52 - Standard Transfer Specification (STS) - Physical Layer Protocol for a two-way virtual token carrier for direct local connection. o SANS 473(2017): Automated meter reading for large power users; and o SANS 474(2009): Code of practice for electricity metering. This specification applies to three-phase bulk BS (British Standard) mounting, Three Phase Commercial and Industrial Meters for CT (current transformer), measurement of alternating current electrical energy consumption at a nominal frequency of 50 Hz. • General Specification: o Voltage ratings: Nominal voltage between 60/100V and 230/400VAC (Voltage Alternating Current) o Supply frequency: 50Hz. o Current ratings (lb): Base current – 1-10A. o Max current (MAX): 100A and above. • Measurement: o True four quadrant measurements of kilowatt-hours delivered or received as well as kilowatt-hours leading and lagging for power delivered or received. o Active, reactive and apparent energy in both import and export mode. o Phase voltage and currents in individual phases and a sum up of the same.
Load Profile(s). The factors used by each EDC for each Designated Green Mountain Customer to allocate the customer's energy usage to each hour of the billing cycle. Load Profile-Type(s): The Load Profile applied to a particular Designated Green Mountain Customer for a particular period of time.

Examples of Load Profile(s) in a sentence

  • The Scheduling Coordinator must immediately notify the CAISO of any changes to the Approved Load Profiles referred to in Schedule 2 to this Agreement and provide the CAISO with a copy of the new or amended Approved Load Profile.

  • The Company will provide the Load Profiles Equations, Rate Code to Profile Mapping, and Loss Factors utilized in the annual Transmission PLC calculation process via the Company’s website.

  • The Cooperative will provide the Load Profiles Equations, Rate Code to Profile Mapping, and Loss Factors utilized in the Settlement Process via the Cooperative’s public website.

  • The Company is replacing all its current load profile samples with Dynamic Load Profiles for the residential, commercial and industrial customers.

  • The Guaranteed Energy Savings for each Phase are based on the assumption that Customer's annual operating hours at those facilities of the Facilities covered in a Phase (the "Operating Hours"), and stipulated load profiles (the "Load Profiles") and run hours (the "Run Hours") depending on the type of Equipment (lighting or mechanical), all as set forth in the applicable Amendment.

  • Onsite guarantees the Guaranteed Energy Savings for each Phase as set forth in each Amendment based upon the Operating Hours, and/or Load Profiles and Run Hours, as applicable.

  • Load Profiles ­ Statistically developed usage patterns by service class and subclasses to calculate hour­by­hour estimates of energy usage in the absence of Hourly Metering.

  • For example: Retail Settlements/Reconciliation Customer Information Customer Switching Load Obligations of the Supplier Load Profiles used by the Distribution Company Utilization of Schedule Coordinators and Agreements System Operations/Curtailment Delivery and Balancing Tariffs and Fees Details on these processes could be included in this Agreement by reference, or actually detailed in the Agreement itself.

  • To the extent that the Supplier has Green Mountain Load Profiles and Distribution Loss Factors for each Energy Delivery Point for each day, that are not easily accessible to Green Mountain, the Supplier shall provide to Green Mountain this information, upon written request.