The percentage of 1- D fuel oil used to ensure the proper CFPP temperature shall not exceed fifty (50%) percent of the base oils mix ratio.
Delivered product having a CFPP temperature of seven and one-half (7.5°C) degrees Centigrade, or greater, above the maximum shall be removed from the site upon the State’s request and the Contractor shall pay a price deduction as detailed in the NON-COMPLYING PRODUCT & OPERABILITY TABLE FOR PRICE DEDUCTIONS regardless of whether the fuel oil delivery is removed or not removed.
Cetane and cold filter plugging point (CFPP) parameters shall be met regardless of product mix.
D2500-17a As shown in the "Low Temperature Operability" Table CFPP Point, OC, IP309 As shown in the "Low Temperature Operability" Table Carbon Residue (mass %), max, on 10% Ramsbottom: D524-15 (2019) 0.35 Total Acid Number (TAN), mg KOH/g, maximum D664-18e2 0.25 Corrosion Inhibitors TM0172-2001, ▇▇▇▇ Mfr’s std.
Low temperature fluidity may be improved through the use of LTFT or CFPP additives or by blending with ULSD No. 1 Diesel Fuel.
The low temperature fluidity shall be measured by the Cloud Point (ASTM D2500, D5771, D5772 or D5773), the CFPP (ASTM D6371 or the LTFT (ASTM D4539).
NuScale shall run an ECT promptly after receiving the PCE/OCE and the Financing Plan from CFPP LLC, based on the mutually agreed upon schedule for running such ECTs as described in Paragraph 3.b below.
CFPP and DOE have executed DOE Office of Nuclear Energy Award No. DE- NE008935 for $1.355 billion dated as of October 16, 2020 for the siting and licensing of the Project (the “DOE Award”), with NuScale identified as a contractor, subcontractor or subrecipient under the DOE Award.
CFPP LLC shall also have sixty (60) days to deliver written notice of its intent to terminate its participation in the Project, including termination of this Agreement, any other CFPP LLC agreement with NuScale, and the Development Agreement (or the EPC Contract, if executed) pursuant to Paragraph 5.a. following the occurrence of any of the events listed in Paragraphs 5.a.I or 5.a.2 or the failure to meet the Subscription Target by the earlier of the COLA submittal or February I, 2024.