Common use of Unbundled Copper Loop Clause in Contracts

Unbundled Copper Loop. Designed (UCL-D) 2.4.1.1.1 The UCL-D will be provisioned as a dry copper twisted pair loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). The UCL-D will be offered in two versions - Short and Long. 2.4.1.1.1.1 A short UCL-D (18kft or less) is provisioned according to Resistance Design parameters, may have up to 6kft of bridged tap and will have up to 1300 ohms of resistance. 2.4.1.1.1.2 The long UCL-D (beyond 18kft) is provisioned as a dry copper twisted pair longer than 18kft and may have up to 12kft of bridged tap and up to 2800 ohms of resistance. 2.4.1.1.2 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by NAS. 2.4.1.1.3 These loops are not intended to support any particular services and may be utilized by NAS to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.1.1.4 BellSouth will make available the following UCL-Ds: 2.4.1.1.4.1 2-Wire UCL-D/short 2.4.1.1.4.2 2-Wire UCL-D/long 2.4.1.1.4.3 4-Wire UCL-D/short 2.4.1.1.4.4 4-Wire UCL-D/long

Appears in 1 contract

Sources: Clec Agreement

Unbundled Copper Loop. Designed (UCL-D) 2.4.1.1.1 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). The UCL-D will be offered in two versions - Short and Long. 2.4.1.1.1.1 2.4.2.2 A short UCL-D (18kft or less) is provisioned according to Resistance Design parameters, may have up to 6kft of bridged tap and will have up to 1300 ohms of resistance. 2.4.1.1.1.2 2.4.2.3 The long UCL-D (beyond 18kft) is provisioned as a dry copper twisted pair longer than 18kft and may have up to 12kft of bridged tap and up to 2800 ohms of resistance. 2.4.1.1.2 2.4.2.4 The UCL-D is a designed circuit, is provisioned with a test point, point and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by NASMoney To Go. 2.4.1.1.3 2.4.2.5 These loops are not intended to support any particular services and may be utilized by NAS Money To Go to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.1.1.4 2.4.2.6 BellSouth will make available the following UCL-Ds: 2.4.1.1.4.1 2-Wire UCL-D/short 2.4.1.1.4.2 2-Wire UCL-D/long 2.4.1.1.4.3 4-Wire UCL-D/short 2.4.1.1.4.4 4-Wire UCL-D/long:

Appears in 1 contract

Sources: Clec Agreement