Specific Technical Requirements. 5.1 technical requirements concerning front position lamps, (symbols A, MA) and front end-outline marker lamps, (symbols AM) 5.1.1. The light emitted by each of the two lamps supplied shall meet the requirements in Table 3. Table 3 Luminous intensities for front position and front end-outline marker lamps Minimum luminous intensity in HV (values in cd) Maximum luminous intensity in any direction when used as (values in cd) A single lamp A lamp marked "D" (paragraph 3.3.2.5.2.) Front position lamps, front end-outline marker lamp, A or AM 4 140 70 Front position lamps (motorcycle), MA 4 140 N.A. Front position lamps A incorporated in a headlamp or in a front fog lamp 4 140 N.A. 5.1.2. Outside the reference axis and within the angular fields defined in the diagrams in Part A of Annex 2, the intensity of the light emitted by each lamp must in each direction corresponding to the points in the table of standard light distribution reproduced in paragraph 2. of Annex 3, be not less than the minimum specified in paragraph 5.1.1., multiplied by the percentage specified in the said table of the direction in question. 5.1.3. Throughout the fields defined in the diagrams in Part A of Annex 2, the luminous intensity of the light emitted must be not less than 0.05 cd for front position lamps and front end-outline marker lamps; 5.1.4. The colour of the light emitted shall be white, however the lamp identified by symbol ‘MA’ may be amber.
Appears in 3 contracts
Sources: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles
Specific Technical Requirements. 5.1 technical requirements concerning front position lamps, (symbols A, MA) and front end-outline marker lamps, (symbols AM)
5.1.1. The light emitted by each of the two lamps supplied shall meet the requirements in Table 3. Table 3 Luminous intensities for front position and front end-outline marker lamps Minimum luminous intensity in HV (values in cd) Maximum luminous intensity in any direction when used as (values in cd) A single lamp A lamp marked "D" (paragraph 3.3.2.5.2.) Front position lamps, front end-outline marker lamp, A or AM 4 140 70 Front position lamps (motorcycle), MA 4 140 N.A. Front position lamps A incorporated in a headlamp or in a front fog lamp 4 140 N.A.
5.1.2. Outside the reference axis and within the angular fields defined in the diagrams in Part A of Annex 2, the intensity of the light emitted by each lamp must in each direction corresponding to the points in the table of standard light distribution reproduced in paragraph 2. of Annex 3, be not less than the minimum specified in paragraph 5.1.1., multiplied by the percentage specified in the said table of the direction in question.
5.1.3. Throughout the fields defined in the diagrams in Part A of Annex 2, the luminous intensity of the light emitted must be not less than 0.05 cd for front position lamps and front end-outline marker lamps;
5.1.4. The colour of the light emitted shall be white, however the lamp identified by symbol ‘MA’ may be amber.
Appears in 1 contract
Sources: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations