Common use of Setting conditions Clause in Contracts

Setting conditions. The setting conditions shall conform to the manufacturer's specifications for the production motor and be used without further alteration for the particular application. 2.5. Data to be recorded 2.5.1. The test for determining the net power shall be carried out with the accelerator control set at the maximum position. 2.5.2. The motor must have been run-in in accordance with the recommendations of the applicant for the approval. 2.5.3. Torque and speed data shall be recorded simultaneously. 2.5.4. If needed, the cooling liquid temperature recorded at the motor outlet must be maintained at ±5 K of the thermostat temperature setting specified by the manufacturer. For air cooling drive trains, the temperature at a point indicated by the manufacturer shall be kept within +0/-20 K of the maximum value specified by the manufacturer. 2.5.5. The temperature of the lubricating oil measured in the oil sump or at the outlet from the oil temperature exchanger (if any) shall be maintained within the limits prescribed by the manufacturer. 2.5.6. An auxiliary regulating system may be used, if necessary, to maintain the temperature within the limits specified in paragraphs 2.5.4. and 2.5.5. above.

Appears in 2 contracts

Sources: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles