Remote Sites Sample Clauses

Remote Sites. In connection with the license granted to Licensee by Licensor pursuant to this Agreement, Licensee shall have the right, at its sole expense, to transport one or more Simulators to locations other than the premises of the Entertainment Stores temporarily operated by Licensee (individually a "Remote Site" or collectively the "Remote Sites") for the purpose of making the Simulators available for use by the general public at sporting or other entertainment and promotional events; provided that the locations and times of operation for each Remote Site has been previously approved in writing by Licensor; and further provided that, in connection with each Remote Site, Licensee complies with all of the terms and conditions of this Agreement applicable to the Entertainment Stores insofar as such terms and conditions could apply to the Simulators or the Remote Site. Notwithstanding the foregoing, in connection with the Remote Sites, except with respect to the fee charged by Licensee with respect to the use and operation of the Simulators by customers, Licensee shall not be permitted to sell at or around a Remote Site located at or in close proximity to any NASCAR-sanctioned race track facility, any merchandise or other products or services bearing, containing or displaying the NASCAR Marks, without Licensor's prior approval. Licensee shall be permitted to sell approved merchandise at locations other than NASCAR-sanctioned race track facilities, provided that Licensee has obtained any and all necessary permits, permissions, licenses, etc. necessary for this type of activity.
AutoNDA by SimpleDocs
Remote Sites. The following functionality is required: • The security alarm systems shall comprise Paradox or Risco or DSC modules or equivalent compatible alternatives as specified. These shall be housed in metal boxes with locks and keys. • In the main Passive Infrared Detectors are used in conjunction with magnetic contacts for doors and contractors shall be required to design each circuit and zone to cater for the requirements of the site. End of line resistors shall be installed at the correct position, not at the panel. Passive Infrared Detectors shall be for indoor use Pro Passive or equivalent and outdoor use DG85 or equivalent. • The install codes shall be provided to the City’s Representative at the time of handover. • In the case where a dedicated telephone line or extension on a PABX or equivalent is available, the panel shall be set up to dial the control room alarm number.
Remote Sites. The following functionality is required: • The security alarm systems shall comprise Paradox or Risco or DSC modules or equivalent compatible alternatives as specified. These shall be housed in metal boxes with locks and keys. • In the main Passive Infrared Detectors are used in conjunction with magnetic contacts for doors and contractors shall be required to design each circuit and zone to cater for the requirements of the site. End of line resistors shall be installed at the correct position, not at the panel. Passive Infrared Detectors shall be for indoor use Pro Passive or equivalent and outdoor use DG85 or equivalent. • The install codes shall be provided to the City’s Representative at the time of handover. • In the case where a dedicated telephone line or extension on a PABX or equivalent is available, the panel shall be set up to dial the control room alarm number. • If a radio is required at a site, the radio shall be a VHF QD alarm radio or Finmon modem or equivalent, compatible with the City’s dedicated alarm systems. The radio antenna shall be the folded dipole type and shall be installed in a secure place at least 2m away from panels, PIRs, electronic equipment, electrical distribution boards and any metal. The Finmon modem or equivalent extension antenna shall be at least a quarter wave antenna, and shall be installed in a secure place at least 2m away from panels, PIRs, electronic equipment, electrical distribution boards and any metal. • The contractor shall ensure there is adequate coverage at the point where the antenna is installed. • The 12VDC supply for the equipment shall be supplied directly from the standby battery using not less than 0.5mm2 two core Cabtyre cable. • Where radio coverage is poor or the radios reliability is questionable the panel shall be able to be connected to a Finmon modem or equivalent or Spread Spectrum device or an Ethernet or equivalent IEEE802.3 point on the Corporate Local Area Network. • The alarm panel shall be powered from 16VAC-50VA transformers. • Sealed backup batteries 12V-7AH shall be installed on all modules. • If the alarm panel is used to control access to certain doors, the door locks shall be connected to the alarm panel via external relays/relay modules powered from their own power supply with battery backup. No power shall be drawn from the panel or expanders and their relevant power supplies. Power supplies for the locks shall be 3 Amp, model number PS 49-1 available from Regal or equivalen...
Remote Sites. Contractor shall provide repair services to the remote sites (City Police Departments as referenced in Section B. 1. through 12.), 8 hours a day, five (5) days a week, with a response time of no more than four (4) hours, each incident.
Remote Sites. The Contractor shall perform work as specified at remote locations. The Contractor shall be responsible for all personnel, supplies, equipment, and infrastructure (including, but not limited to, potable water, utility systems, housing, dining, transportation, and medical care) when there are no facilities and services available.

Related to Remote Sites

  • Remote Access Access to and use of the Data over the State Governmental Network (SGN) or Secure Access Washington (SAW) will be controlled by DSHS staff who will issue authentication credentials (e.g. a Unique User ID and Hardened Password) to Authorized Users on Contractor’s staff. Contractor will notify DSHS staff immediately whenever an Authorized User in possession of such credentials is terminated or otherwise leaves the employ of the Contractor, and whenever an Authorized User’s duties change such that the Authorized User no longer requires access to perform work for this Contract.

  • Sites Sites shall mean the locations set forth in the Contract Documentation.

  • Remote Terminal Unit Prior to the Initial Synchronization Date of the Large Generating Facility, a Remote Terminal Unit, or equivalent data collection and transfer equipment acceptable to the Parties, shall be installed by Developer, or by Connecting Transmission Owner at Developer’s expense, to gather accumulated and instantaneous data to be telemetered to the location(s) designated by Connecting Transmission Owner and NYISO through use of a dedicated point-to-point data circuit(s) as indicated in Article 8.1. The communication protocol for the data circuit(s) shall be specified by Connecting Transmission Owner and NYISO. Instantaneous bi-directional analog real power and reactive power flow information must be telemetered directly to the location(s) specified by Connecting Transmission Owner and NYISO. Each Party will promptly advise the appropriate other Party if it detects or otherwise learns of any metering, telemetry or communications equipment errors or malfunctions that require the attention and/or correction by that other Party. The Party owning such equipment shall correct such error or malfunction as soon as reasonably feasible.

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Site Lands or areas indicated in the Contract Documents as being furnished by the Owner upon which the Work is to be performed, including rights-of-way and easements for access thereto, and such other lands furnished by the Owner that are designated for the use of the Contractor. Also referred to as Project Site, Job Site and Premises.

  • Unbundled Network Element Combinations 4.1 For purposes of this Section, references to “Currently Combined” Network Elements shall mean that the particular Network Elements requested by NewPhone are in fact already combined by BellSouth in the BellSouth network. References to “

  • Unbundled Network Elements 35.4.1. The charges that CLEC shall pay to Sprint for Unbundled Network Elements are set forth in Table One of this Agreement. 35.5. Collocation

  • Internet Connection In order to ensure the proper functioning of the Production Monitor and the Consumption Monitor, if possible, you must provide the Solar System with continuous access to a functioning broadband internet connection with one (1) wired Ethernet port and standard electrical outlet, at your cost. If you are unable to provide the Solar System with an internet connection in accordance with the foregoing sentence, the Home must be located in an area with cellular service that is acceptable to us in our discretion.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • The Site The site of the Project Highway (the “Site”) shall comprise the site described in Schedule-A in respect of which the Right of Way shall be provided by the Authority to the Contractor. The Authority shall be responsible for:

Time is Money Join Law Insider Premium to draft better contracts faster.