REINFORCING Sample Clauses

The REINFORCING clause establishes requirements or standards for the use of reinforcing materials, such as steel bars or mesh, within a construction project. It typically specifies the type, grade, placement, and installation methods for reinforcement to ensure structural integrity, and may reference relevant codes or testing procedures. By clearly defining these expectations, the clause helps prevent construction defects and ensures that the finished structure meets safety and durability standards.
REINFORCING. PSG 5.1.2 Fixing
REINFORCING. The prices/ rates for steel reinforcing shall include for the supply, cutting, bending, lowering and hoisting of reinforcing to the various work areas, placing and wiring in position with and including 1.60 or 1.25mm diameter annealed wire, spacer blocks shall be deemed to be included in the rates / prices of the reinforcing. Prices/ rates for fabric reinforcing shall include for unrolling, cutting, bending and binding wire, and for a minimum of 300mm side and end laps, hoisting or lowering and fixing and maintaining in position. Section No. 3 Bill No. 3 Concrete, Formwork and Reinforcement UNREINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES 1 Surface blinding under footings m3 1 REINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES 2 Strip footings m3 7 3 Surface beds cast in panels on waterproofing m3 16 4 Ramps m3 3 5 Steps m3 3 6 Making and testing 150 x 150 x 150mm concrete strength test cubes (Provisional) No 10
REINFORCING. Steel reinforcement shall comply with the respective Australian Standards AS 1302, AS 1303 and AS 1304.
REINFORCING. Steel Reinforcement Materials shall conform to the requirements of current Standard Specifications of the Michigan Department of Transportation.
REINFORCING. A. Reinforcing Bars: ASTM A615, Grade 60, deformed billet-steel, clean and free from rust, scale, or coating that will reduce bond. B. Welded Wire Fabric: ASTM A185. Tags designating wire size and spacing shall be left on each roll until ready for use.
REINFORCING. Reinforcing of sidewalks will not be required except in unusual conditions where the City Engineer may require reinforcing or welded wire fabric. When welded wire fabric is used it shall be placed two inches (2'') from the finished surface of the sidewalk. There will be no direct payment for this item, and it shall be subsidiary to the unit price bid for sidewalk replacement.
REINFORCING. No less than one (1) Employee on all concrete pours, walls, mats and floors, wherever reinforcing is in concrete. Where #6 wire mesh or heavier is used, not less than two (2) Employees shall be employed in the cutting and laying, and not less than one (1) Employee in mucking and pulling and maintaining. Employing two (2) men shall only apply where #6 or heavier mesh is used in building work only.