Reactive Power Requirements Clause Samples
Reactive Power Requirements. Generation resources must be capable of producing a defined quantity of reactive power to maintain a Voltage Profile established by ERCOT Nodal Protocol 3.15. The generator voltage-var schedule, voltage regulator, and transformer ratio settings will be jointly determined by TSP and Generator to ensure proper coordination of voltages and regulator action. The Plant must generate reactive requirements for the Plant and GIF. TSP may, in order to maintain security of the ERCOT power system, request Generator to adjust voltage schedule to accept or supply reactive power.
1. Synchronous Generators shall comply with the following reactive power requirements: an over-excited (lagging) power factor capability of ninety-five hundredths (0.95) or less and an under- excited (leading) power factor capability of ninety-five hundredths (0.95) or less, both determined at the generating unit’s maximum net power to be supplied to the ERCOT transmission grid and at the transmission system Voltage Profile established by ERCOT, and both measured at the Point of Interconnection. The reactive power requirements shall be available at all MW output levels.
2. Induction Generators shall comply with the following reactive power requirements: an over-excited (lagging) power factor capability of ninety-five hundredths (0.95) or less and an under- excited (leading) power factor capability of ninety-five hundredths (0.95) or less, both determined at the generating unit's maximum net power to be supplied to the ERCOT transmission grid and at the transmission system Voltage Profile established by ERCOT, and both measured at the Point of Interconnection. The reactive power requirements shall be available at all MW output levels and may be met through a combination of the Generation Resource’s Unit Reactive Limit (“URL”), which is the generating unit’s dynamic leading and lagging operating capability, and/or dynamic VAR capable devices. For Wind Generation Resources (“WGR”), the reactive power requirements shall be available at all MW output levels at or above ten percent (10%) of the WGR’s nameplate capacity. When a WGR is operating below ten percent (10%) of its nameplate capacity and is unable to support voltage at the Point of Interconnection, ERCOT may require a WGR to disconnect from the ERCOT transmission grid.
3. Other Generators shall comply with the following reactive power requirements: an over-excited (lagging) power factor capability of ninety-five hundredths (0.95) or less and...
Reactive Power Requirements. Idaho Power will determine the reactive power required to be supplied by the Company to the Customer Generator, based upon information provided by the Customer Generator. The Company will specify the equipment required on the Company’s system to meet the Facility’s reactive power requirements. These specifications will include but not be limited to equipment specifications, equipment location, Company-provided equipment, Customer Generator provided equipment, and all costs associated with the equipment, design and installation of the Company-provided equipment. The equipment specifications and requirements will become an integral part of this Agreement. The Company-owned equipment will be maintained by the Company, with total cost of purchase, installation, operation, and maintenance, including administrative cost to be reimbursed to the Company by the Customer Generator. Payment of these costs will be in accordance with Schedule 68 and the total reactive power cost will be included in the calculation of the monthly facilities charge.
Reactive Power Requirements. Generation resources must be capable of producing a defined quantity of reactive power to maintain a Voltage Profile established by ERCOT Nodal Protocol 3.15. The generator voltage-var schedule, voltage regulator, and transformer ratio settings will be jointly determined by TSP and Generator to ensure proper coordination of voltages and regulator action. The Plant must generate reactive requirements for the Plant and GIF. TSP may, in order to maintain security of the ERCOT power system, request Generator to adjust voltage schedule to accept or supply reactive power.
1. Synchronous Generators shall comply with the following reactive power requirements: an over-excited (lagging) power factor capability of ninety-five hundredths (0.95) or less and an under- excited (leading) power factor capability of ninety-five hundredths
Reactive Power Requirements. Public Utility will determine the reactive power required to be supplied by the Public Utility to the Interconnection Customer, based upon information provided by the Interconnection Customer. The Public Utility will specify the equipment required on the Public Utility’s system to meet the Facility’s reactive power requirements. These specifications will include but not be limited to equipment specifications, equipment location, Public Utility-provided equipment, Interconnection Customer provided equipment, and all costs associated with the equipment, design and installation of the Public Utility-provided equipment. The equipment specifications and requirements will become an integral part of this Agreement. The Public Utility-owned equipment will be maintained by the Public Utility, with total cost of purchase, installation, operation, and maintenance, including administrative cost to be reimbursed to the Public Utility by the Interconnection Customer. Payment of these costs will be in accordance with Schedule 72 and the total reactive power cost will be included in the calculation of the Monthly Operation and Maintenance Charges specified in Schedule 72. A. Technical Standards Applicable to a Wind Generating Plant
Reactive Power Requirements. Attachment 6