Pipeline Gas Specification Sample Clauses
Pipeline Gas Specification. The Pipeline Gas Specification is:
(a) the specifications for “fuel gas” imposed under the Petroleum and Gas (Production and Safety) Act 2004 (Qld) which adopts the specification set out in Australian Standard “AS 4564 – specification for general purpose natural gas” (2011) (as set out below); and
(b) any additional parameters lawfully required by the APA Group for receipt of gas at the connection between the Pipeline and the Carpentaria Gas Pipeline. ▇▇▇▇▇ Index Minimum 46.0 MJ/m3 Maximum 52.0 MJ/m3 Gross heating value Maximum 42.3 MJ/m3 Oxygen Maximum 0.2 mol% Hydrogen sulphide Maximum 5.7 mg/m3 Total sulphur Maximum 50 mg/m3 Water content Maximum Dewpoint 0oC at the highest MAOP in the relevant transmission system (in any case, no more than 112.0 mg/m3) Hydrocarbon dewpoint Maximum 2.0oC at 3500 kPa gauge Total inert gases Maximum 7.0 mol% Oil Maximum 20 mL/TJ