Parallel Operation or Parallel Sample Clauses

Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator Facility to the Electric Distribution System. Point of Interconnection - The point where the Small Generator Facility is electrically connected to the Electric Distribution System. Point of Interconnection has the same meaning as the term point of common coupling defined in 3.1.13 of IEEE Standard 1547. Small Generator Facility - The equipment used by an interconnection customer to generate, or store electricity that operates in parallel with the Electric Distribution System. A Small Generator Facility typically includes an electric generator, prime mover, and the Interconnection Equipment required to safely interconnect with the Electric Distribution System or a local electric power system.
AutoNDA by SimpleDocs
Parallel Operation or Parallel. The state of operation that occurs when a distributed generation facility is connected electrically to the electric distribution system for longer than 100 milliseconds. Point of interconnection - The point where the distributed generation facility is electrically connected to the electric distribution system. Point of interconnection has the same meaning as the term "point of common coupling" defined in 3.1 of IEEE Standard 1547. Qualifying facility - A cogeneration facility or a small power production facility that is a qualifying facility under 18 CFR Part 292, Subpart B, used by an interconnection customer to generate electricity that operates in parallel with the electric distribution system. A qualifying facility typically includes an electric generator and the interconnection equipment required to interconnect safely with the electric distribution system or local electric power system. Utility - Any electric utility that is subject to rate regulation by the Iowa Utilities Board.
Parallel Operation or Parallel. The state of operation that occurs when a distributed generation facility is connected electrically to the electric distribution system.
Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator Facility to the Electric Distribution System.
Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator Facility to the Electric Distribution System. Point of Interconnection - The point where the Small Generator Facility is electrically connected to the Electric Distribution System. Point of Interconnection has the same meaning as the term point of common coupling defined in 3.1.13 of IEEE Standard 1547. Small Generator Facility - The equipment used by an interconnection customer to generate, or store electricity that operates in parallel with the Electric Distribution System with a nameplate capacity equal to or less than 10 MW. A Small Generator Facility includes an electric generator, prime mover, and the Interconnection Equipment required to safely interconnect with the Electric Distribution System or a local electric power system. Witness Test— For lab certified or field approved equipment, verification (either by an on-site observation or review of documents) by the EDC that the interconnection installation evaluation required by IEEE Standard 1547 Section 5.3 and the commissioning test required by IEEE Standard 1547 Section 5.4 have been adequately performed. For interconnection equipment that has not been lab certified or field approved, the witness test shall also include the verification by the EDC of the on-site design tests as required by IEEE Standard 1547 Section 5.1 and verification by the EDC of production tests required by IEEE Standard 1547 Section 5.2. All tests verified by the EDC are to be performed in accordance with the test procedures specified by IEEE Standard 1547.1. Attachment 2 Construction Schedule, Proposed Equipment & Settings This attachment shall include the following:
Parallel Operation or Parallel. The state of operation that occurs when a Distributed Generation Facility is connected electrically to the Electric Distribution System for longer than 100 milliseconds. Point of Common Coupling (PCC) – The point where the Distributed Generation Facility is electrically connected to the Electric Distribution System. Point of interconnection has the same meaning as the term Point of Common Coupling defined in IEEE Standard 1547. The PCC is typically the electric meter, unless otherwise stated. Source – The electricity provided from the LGMU system. UL 1741 – The Underwriters Laboratories Standard 1741, “Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources.” INTENTION AND DESCRIPTION OF THE AGREEMENT This Agreement is intended for any Interconnecting Party wanting to install generating equipment on LGMU’s system. Typical installations include, but are not limited to, solar panels and wind turbines. This agreement can support intended installations with a generating capacity of up to 500kW in size, and over this size an interconnection shall be guided by the policies of the Transmission Provider, Midcontinent Independent System Operator (MISO). For installations of 20 kW and smaller with inverters that are pre-certified, expedited analysis of applications will apply. This Agreement governs the terms and conditions under which the Distributed Generation Facility will interconnect to, and operate in parallel with, the LGMU’s Electric Distribution System. This Agreement does not constitute an agreement to purchase or deliver the Interconnecting Party’s power. Nothing in this Agreement is intended to affect any other agreement between the LGMU and the Interconnecting Party. These systems operate in parallel with electricity from the power lines to the premises. Should the Source lose power for any reason, the Interconnecting Party’s System shall automatically prevent energization of the LGMU system. This Agreement references codes, standards, and practices to have a safely operating system. If any of these requirements are not met, there exists a potential for damage to equipment and/or personal harm, as well as possibly discontinuing the use of the Interconnecting Party’s System. LGMU shall construct, own, operate, and maintain its Interconnection Facilities in accordance with this Agreement. The Interconnection Customer shall construct, own, operate, and maintain its Distributed Generation Facility an...
Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator facility Facility to the Electric Distribution System. Party or Parties – EDC, Interconnection Customer or any combination of the two. Point of Interconnection - The point where the Small Generator Facility is electrically connected to the Electric Distribution System. Point of Interconnection has the same meaning as the term point of common coupling defined in 3.1.13 of IEEE Standard 1547. Small Generator Facility - The equipment used by an interconnection customer to generate, or store electricity that operates in parallel with the Dlectric Electric Distribution System. A Small Generator Facility typically includes an electric generator, prime mover, and the Enterconnection Interconnection Equipment required to safely interconnect with the Electric Distribution System or a local electric power system. Witness Test - The EDC's interconnection installation evaluation required by IEEE Standard 1547 Section 5.3 and the EDC's witnessing of the commissioning test required by IEEE Standard 1547 Section 5.4. For interconnection equipment that has not been lab certified or field certified, the Witness Test shall also include the witnessing by the EDC of the on-site design tests as required by IEEE Standard 1547 Section 5.1 and witnessing by the EDC of production tests required by IEEE Standard 1547 Section 5.2. All tests witnessed by the EDC are to be performed in accordance with IEEE Standard 1547.1 Attachment 1 DESCRIPTION OF FACILITY Facility description: Description of generating unit(s) (the Customer Facility) to be interconnected with the Transmission System in the PJM Region:
AutoNDA by SimpleDocs
Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator Facility to the Electric Distribution System. Point of Interconnection - The point where the Small Generator Facility is electrically connected to the Electric Distribution System. Point of Interconnection has the same meaning as the term point of common coupling defined in 3.1.13 of IEEE Standard 1547. Small Generator Facility - The equipment used by an interconnection customer to generate, or store electricity that operates in parallel with the Electric Distribution System. A Small Generator Facility typically includes an electric generator, prime mover, and the Interconnection Equipment required to safely interconnect with the Electric Distribution System or a local electric power system. Witness Test— For lab certified or field approved equipment, verification (either by an on-site observation or review of documents) by the EDC that the interconnection installation evaluation required by IEEE Standard 1547 Section 5.3 and the commissioning test required by IEEE Standard 1547 Section 5.4 have been adequately performed. For interconnection equipment that has not been lab certified or field approved, the witness test shall also include the verification by the EDC of the on-site design tests as required by IEEE Standard 1547 Section 5.1 and verification by the EDC of production tests required by IEEE Standard 1547 Section 5.2. All tests verified by the EDC are to be performed in accordance with the test procedures specified by IEEE Standard 1547.1. Attachment 2 Construction Schedule, Proposed Equipment & Settings This attachment shall include the following:
Parallel Operation or Parallel. The state of operation that occurs when a distributed generation facility is connected electrically to the electric distribution system. Point of interconnection – The point where the distributed generation facility is electrically connected to the electric distribution system. Point of interconnection has the same meaning as the term "point of common coupling" defined in 3.1.13 of IEEE Standard 1547.
Parallel Operation or Parallel. The state of operation which occurs when a Small Generator Facility is connected electrically to the Electric Distribution System and the potential exists for electricity to flow from the Small Generator facility to the Electric Distribution System. Party or Parties – EDC, Interconnection Customer or any combination of the two. Point of Interconnection - The point where the Small Generator Facility is electrically connected to the Electric Distribution System. Point of Interconnection has the same meaning as the term point of common coupling defined in 3.1.13 of IEEE Standard 1547. Small Generator Facility - The equipment used by an interconnection customer to generate, or store electricity that operates in parallel with the Dlectric Distribution System. A Small Generator Facility typically includes an electric generator, prime mover, and the Enterconnection Equipment required to safely interconnect with the Electric Distribution System or a local electric power system. Witness Test - The EDC's interconnection installation evaluation required by IEEE Standard 1547 Section 5.3 and the EDC's witnessing of the commissioning test required by IEEE Standard 1547 Section 5.4. For interconnection equipment that has not been lab certified or field certified, the Witness Test shall also include the witnessing by the EDC of the on-site design tests as required by IEEE Standard 1547 Section 5.1 and witnessing by the EDC of production tests required by IEEE Standard 1547 Section 5.2. All tests witnessed by the EDC are to be performed in accordance with IEEE Standard 1547.1 Attachment 2 One-line Diagram Depicting the Small Generator Facility, Interconnection Facilities, Metering Equipment, and Distribution Upgrades Attachment 3 Description, Costs and Time Required to Build and Install EDC’s Interconnection Facilities EDC’s Interconnection Facilities and any required Distribution Upgrades shall be itemized and a best estimate of itemized costs, including overheads, shall be provided based on the Facilities Study. Also, a best estimate for the time required to build and install EDC’s Interconnection Facilities will be provided based on the Facilities Study. Attachment 4 Additional Operating Requirements for Small Generator Facilities Operating in Parallel 22