Common use of Maintenance Information Clause in Contracts

Maintenance Information. Maintenance of the Product Family Elegant and Legend Pager Mechanical Interface consists of keeping the spring-loaded contacts clean and making sure the RJ-11 plugs are properly seated in the receptacle on the Pager Mechanical Interface and the Programming Interface. The contacts can be cleaned with a soft, dry cloth. Do not use any solvents to clean the contacts or the outside of the interface. If necessary, a damp (not wet) cloth can be used to clean the outside of the fixture. Do not immerse in water or other liquid. In case of erratic operation, inspect the coiled cable between the Programming Interface and the Pager Mechanical Interface. If it appears to be damaged, or the contacts on the plug at either end appear weak or damaged, replace the cable. When ordering replacement parts or equipment information, complete identification numbers must be included. This applies to all components, kits, and chassis. If the component part number is not known, the order must include the number of the chassis or kit number of which it is a part. If the identical replacement part is not locally available, check the parts list for the proper Unication part number and order the part from the nearest Unication replacement parts depot, listed below. Call: (▇▇▇) ▇-▇▇▇▇▇▇▇▇ In North America Call: ▇▇▇-▇▇▇-▇▇▇▇ In Asia Call Call: ▇▇▇-▇▇▇-▇▇▇▇ Call: (▇▇▇-▇▇▇-▇▇▇▇ In Asia Call Does Product Family Alpha Gold programming software run on COM3 ~ COM8? Yes, as long as no other device is connected to these ports. When reading a pager, either the mouse no longer works or communication with the pager cannot be re-established. This error often results from setting an asynchronous mouse to the same communication port interrupt used for the programming software. It is recommended that one of the communication ports be changed. Check that both devices are not set to even. Check that both devices are not set to odd. If either of these conditions exist, reset one device opposite of the other port. The programming software reports a Data Communications error and never reads the pager. Check the Programming Interface cable for correct installation. This is usually a 9- or 25-pin male connector on the back of the computer. Make sure the power supply cable is connected to a power source. Make sure the pager is in the ON position and firmly seated in the Mechanical Interface. (The red LED is illuminated.) Check if there are any RAM-resident programs running. Pager does not function after programming has been performed. Make sure the capcode has not been changed. Check all functions; ensure the entries have not been programmed as either inactive or incorrectly. Make sure the Data Inversion parameter has not been changed. How to check available COM port for PPS? Ans:

Appears in 1 contract

Sources: Software License Agreement

Maintenance Information. Maintenance of the Product Family Elegant and Legend Pager Mechanical Interface consists of keeping the spring-loaded contacts clean and making sure the RJ-11 plugs are properly seated in the receptacle on the Pager Mechanical Interface and the Programming Interface. The contacts can be cleaned with a soft, dry cloth. Do not use any solvents to clean the contacts or the outside of the interface. If necessary, a damp (not wet) cloth can be used to clean the outside of the fixture. Do not immerse in water or other liquid. In case of erratic operation, inspect the coiled cable between the Programming Interface and the Pager Mechanical Interface. If it appears to be damaged, or the contacts on the plug at either end appear weak or damaged, replace the cable. When ordering replacement parts or equipment information, complete identification numbers must be included. This applies to all components, kits, and chassis. If the component part number is not known, the order must include the number of the chassis or kit number of which it is a part. If the identical replacement part is not locally available, check the parts list for the proper Unication part number and order the part from the nearest Unication replacement parts depot, listed below. Call: (▇▇▇) ▇-▇▇▇▇▇▇▇▇ In North America Support: Call: ▇▇▇-▇▇▇-▇▇▇▇ In North America In Asia Call Call: ▇▇▇-▇▇▇-▇▇▇▇ Call: (▇▇▇-▇▇▇-▇▇▇▇ In Asia Call Call: ▇▇▇-▇▇▇-▇▇▇▇ Does Product Family Alpha Gold programming software run on COM3 ~ COM8? Yes, as long as no other device is connected to these ports. When reading a pager, either the mouse no longer works or communication with the pager cannot be re-established. This error often results from setting an asynchronous mouse to the same communication port interrupt used for the programming software. It is recommended that one of the communication ports be changed. Check that both devices are not set to even. Check that both devices are not set to odd. If either of these conditions exist, reset one device opposite of the other port. The programming software reports a Data Communications error and never reads the pager. Check the Programming Interface cable for correct installation. This is usually a 9- or 25-pin male connector on the back of the computer. Make sure the power supply cable is connected to a power source. Make sure the pager is in the ON position and firmly seated in the Mechanical Interface. (The red LED is illuminated.) Check if there are any RAM-resident programs running. Pager does not function after programming has been performed. Make sure the capcode has not been changed. Check all functions; ensure the entries have not been programmed as either inactive or incorrectly. Make sure the Data Inversion parameter has not been changed. How to check available COM port for PPS? Ans:

Appears in 1 contract

Sources: Software License Agreement