Load test two. 6.2.2.1. At least one door latch system, when in the fully latched position, shall not separate when a load of 9,000 N is applied in the direction of the fork-bolt opening and parallel to the face of the latch when tested in accordance with paragraph 7.2.1.1. 6.2.2.2. In the case of a primary door latch system, when in the secondary latched position, the primary latch system shall not separate when a load of 4,500 N is applied in the same direction as paragraph 6.2.2.1., when tested in accordance with paragraph 7.2.1.1.
Load test two. 2.2.1. Equipment: Tensile testing fixture (see Figure 3-2). 2.2.2. Procedures 2.2.2.1. Fully Latched Position 2.2.2.1.1. Adapt the test fixture to the mounting provisions of the latch and striker. Mount the latch and striker in the fully latched position to the test fixture. 2.2.2.1.2. Apply the test load, in the direction specified in paragraph 6.1.2. of this Regulation and Figure 3-4, at a rate not to exceed 5 mm/min until the required load has been achieved. Record the maximum load achieved. 2.2.2.2. Secondary Latched Position 2.2.2.2.1. Adapt the test fixture to the mounting provisions of the latch and striker. Mount the latch and striker in the secondary latched position to the test fixture. 2.2.2.2.2. Apply the test load, in the direction specified in paragraph 6.1.2. of this Regulation and Figure 3-4, at a rate not to exceed 5 mm/min until the required load has been achieved. Record the maximum load achieved.