Grading/Excavation Clause Samples

Grading/Excavation. Construction grading and excavation activities associated with applicable WHRS project activities require coordination and compliance as follows: 1. Grading/excavation project manager/contractor’s representative (PM/CR) must contact the Technical Representative (TR) at least 14 days prior to initiation of grading/excavation work to discuss anticipated conditions and any special precautions to consider. 2. The PM/CR must arrange for all utility clearance. 3. The PM/CR must meet with the TR to discuss task – specific precautions (as detailed in any and all applicable work activities described in this Section). 4. A TR must be on-site or on call to respond to questions or observations that could require sampling or determinations relevant to management of impacted soil or debris. It is the responsibility of the PM/CR to notify the TR of construction schedules and activities (including any changes in schedules or scope of work effort) that may require on-site support and observation. 5. Unless superseded by other special considerations, grading/excavation activities may proceed per the contractual project/task plans and specifications. 6. Changing field considerations and observations (including encountering suspect soils/debris/other media or modifications of proposed areas/volumes of soil grading/excavation/filling) must be reported to the TR. 7. If during execution of contractual plans and specifications the PM/CR determines the need to manage excess soils/debris/other media) not previously addressed, the PM/CR will consult with the TR to discuss management of affected media. Resolution and ultimate fate of the affected media will be documented by the TR. 8. Work shutdown will be at the discretion of the PM/CR’s corporate health and safety policies and practices.

Related to Grading/Excavation

  • Excavation If an excavation shall be made upon land adjacent to the Leased Premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the Leased Premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which the Leased Premises form a part from injury or damage and to support the same by proper foundation, without any claim for damages or indemnity from Landlord, or diminution or abatement of Rent.

  • ADJACENT EXCAVATION-SHORING If an excavation shall be made upon land adjacent to the demised premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the demised premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which demised premises form a part from injury or damage and to support the same by proper foundations without any claim for damages or indemnity against Owner, or diminution or abatement of rent.

  • Grading The coarse aggregate as delivered to the mixer, shall be well graded as per IS specifications. Maximum size of aggregate used for the work shall be 20mm or 40mm or as specified in items in the bill of quantities and it shall confirm to IS: 383-1970, clause 4.2 (Table-2) However, the exact gradation required to produce a dense concrete of specified strength and desired workability shall be decided as per laboratory test by the Engineer. Coarse aggregate for use in concrete shall be well graded and shall conform to IS: 383-1970 requirements (as per Table-II) given below: 63mm 100 - - - 40mm ▇▇-▇▇▇ ▇▇▇ - - 20mm ▇▇-▇▇ ▇▇-▇▇▇ 100 - 16mm - - ▇▇-▇▇▇ ▇▇▇ 12.5 - - - 90-100 10.00 ▇▇-▇▇ ▇▇-▇▇ ▇▇-▇▇ ▇▇-▇▇ 4.75mm 0-5 0-10 0-10 0-10

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Upgrading You may request an Upgrade. For purposes of an Upgrade request, each individual who constitutes the Depositor under the agreement for Retail Direct Services is considered a required Signing Officer for purposes of acceptance of the Upgrade, and You agree to ensure that each such individual agrees to the Upgrade and accepts the terms of this Agreement before initiating the Upgrade request. Implementation of an Upgrade is subject to the approval of the Financial Institution. a) if Transactions under Direct Services for Small Business require two Signing Officers to authorize, a Signing Officer who has provided evidence of acceptance of this Agreement can view the Account using an Access Terminal, but cannot use Direct Services for Small Business as set out in this Agreement until at least one other required Signing Officer has evidenced their acceptance of this Agreement to Us; or b) if Transactions under Direct Services for Small Business require one Signing Officer to authorize, a Signing Officer who has provided evidence of acceptance of this Agreement can use Direct Services for Small Business as set out in this Agreement. When evidence of this Agreement being accepted by the required number of Signing Officers has been provided to Us, this Agreement will no longer be Provisionally Accepted, the Upgrade will be complete, and this article 3, Upgrading, will no longer apply. We may, in Our sole discretion, revert to the pre-Upgrade status if evidence of acceptance of this Agreement by all required Signing Officers is not provided in a timely manner as required.