The 'General Technical Information' clause outlines the basic technical requirements, standards, and specifications relevant to the subject matter of the contract or agreement. It typically details the necessary technical data, documentation, or compliance standards that must be met by the parties, such as product specifications, performance criteria, or applicable industry norms. By clearly defining these technical parameters, the clause ensures that all parties have a mutual understanding of the technical expectations, reducing the risk of misunderstandings or disputes related to technical performance or deliverables.
General Technical Information. Enclose copy of site single-line diagram showing configuration and interconnection of all equipment, current and potential circuits and protection and control schemes. Is Single-Line Diagram Enclosed? Yes Enclose copy of site relay list and trip scheme, which shall include all protection, synchronizing and auxiliary relays that are required to operate the Facility in a safe and reliable manner. Are Relay List and Trip Scheme Enclosed? Yes Enclose copy of site three-line diagram (if the Facility’s capacity is greater than or equal to 30 kW) showing potential transformer and current transformer ratios, and details of the Facility’s configuration, including relays, meters, and test switches. Is Three-Line Diagram Enclosed? Yes
General Technical Information. Enclose copy of site electrical One-Line Diagram showing the configuration of all generating facility equipment, current and potential circuits, and protection and control schemes. Is One-Line Diagram Enclosed? Yes Enclose copy of any site documentation that indicates the precise physical location of the proposed generating facility (e.g., USGS topographic map or other diagram or documentation). Proposed Location of Protective Interface Equipment on Property: (Include Address if Different from Application Address) Enclose copy of any site documentation that describes and details the operation of the protection and control schemes. Is Any Available Documentation Enclosed? Yes Enclose copies of schematic drawings for all protection and control circuits, relay current circuits, relay potential circuits, and alarm/monitoring circuits (if applicable). Are Schematic Drawings Enclosed? Yes
General Technical Information. Enclose copy of site single-line diagram showing configuration and interconnection of all equipment, current and potential circuits and protection and control schemes. Is Single-Line Diagram Enclosed? Yes Enclose copy of site relay list and trip scheme, which shall include all protection, synchronizing and auxiliary relays that are required to operate the Generating Facility in a safe and reliable manner. Are Relay List and Trip Scheme Enclosed? Yes Enclose copy of site three-line diagram (if the Generating Facility’s capacity is greater than or equal to 30 kW) showing potential transformer and current transformer ratios, and details of the Generating Facility’s configuration, including relays, meters, and test switches. Is Three-Line Diagram Enclosed? Yes Installing Electrical Contractor: Firm: License No.: Mailing Address: City: State: Zip Code: Telephone: Area Code: Number: Installation Date: Interconnection Date: Building/Electrical code of the county of Generating System Building Permit # (Certificate of Completion or Notice of Electrical Inspection?): Signed (Inspector): Date: Generating systems that utilize inverter technology must be compliant with Institute of Electrical and Electronics Engineers IEEE Std 1547 and Underwriters Laboratories UL 1741 in effect at the time this Agreement is executed. Generating systems that use a rotating machine must be compliant with applicable National Electrical Code, Underwriters Laboratories, and Institute of Electrical and Electronics Engineers standards and rules and orders of the Public Utilities Commission of the State of Hawaii in effect at the time this Agreement is executed. By signing below, the Applicant certifies that the installed generating equipment meets the appropriate preceding requirement(s) and can supply documentation that confirms compliance. Signed (Customer- Generator): Date: Insurance Carrier: GENERATING FACILITY OWNED BY THE CUSTOMER-GENERATOR OR THIRD PARTY OWNER
General Technical Information. Enclose copy of site single-line diagram showing configuration and interconnection of all equipment, current and potential circuits and protection and control schemes. Is Single-Line Diagram Enclosed? Yes Enclose copy of site relay list and trip scheme, which shall include all protection, synchronizing and auxiliary relays that are required to operate the Facility in a safe and reliable manner. Are Relay List and Trip Scheme Enclosed? Yes Enclose copy of site three-line diagram (if the Facility’s capacity is greater than or equal to 30 kW) showing potential transformer and current transformer ratios, and details of the Facility’s configuration, including relays, meters, and test switches. Is Three-Line Diagram Enclosed? Yes Section 6. Installation Details Installing Electrical Contractor: Firm: License No.: Mailing Address: City: State: Zip Code: Telephone: Area Code: Number: Installation Date: Interconnection Date: SHEET NO. 86AM Effective October 22, 2010 APPENDIX B-1 DESCRIPTION OF FACILITY (Continued) Supply certification that the generating system has been installed and inspected in compliance with the local Building/Electrical code of the County of . Permit Number: Signed (Inspector): Date: