GANGWAYS Clause Samples
GANGWAYS. It is the responsibility of the Exhibitor to ensure that gangways in front of the allocated stand are kept free from obstruction during the whole of the time the building is open for the purpose of the Exhibition.
GANGWAYS. Contractor shall provide a safe and convenient means for boarding the vessel at all times. Gangways without completely enclosed sides shall have a safety net installed not more than six (6) feet below and not less than four (4) feet from each side of the full length of the gangway. A minimum of two (2) gangways shall be provided throughout the duration of the overhaul, one (1) forward and one (1) aft. Gangways shall have a nonskid coating on the walking surface and landings and have rollers where sitting on the vessel.
GANGWAYS. The Exhibitor shall not encroach on the gangways in front of their stand and shall ensure that they are kept free from obstruction during the whole time the building is open for the purpose of the Exhibition.
GANGWAYS. The Vessel must furnish its own gangway, unless the Terminal agreed in advance to furnish the gangway. If the Terminal furnishes the gangway, a fee may be charged to the Vessel. Any operational delays resulting from the Vessel not providing a safe gangway will not count as laytime, or time on demurrage.
GANGWAYS. Two (2) safe and convenient gangways must be provided at all times. Both gangways shall be located on the same side of the vessel. One gangway must be sufficient in length (or height, if vertical stair tower is used) to reach the poop deck (forward of the house structure). The other gangway shall be located on the upper deck, location to be determined by crew member. Both gangways should have sides which are enclosed with wire mesh or canvas to a height of 42 inches above the walkway. Size of mesh shall be to provide adequate protection. If approved by the Contracting Officer Representative, a gangway without completely closed sides may be used. In this case the gangway must have metal handrails to a height of 42 inches above the walkway and be complete with a safety net installed not more than 6 feet below and not less than 4 feet on each side for the entire length of the gangway. All gangways shall be installed within two (2) hours of the time the vessel is moored or drydocked (dry), including all appropriate safety features.
GANGWAYS. The gangway shall be as per the provisions of the AIS 052 Bus Code and would meet the statutory requirements. Minimum interior head room at the center line of gangway shall be 1900 mm min. including that in the rear overhang area.
