Fire Alarm System. The Sportsplex and Arena are equipped with a Single Stage Fire Alarm System. The Xxxx Park Chalet is equipped with smoke detectors. Once you hear the fire alarm or smoke detector you must prepare for immediate evacuation directly to the outside of the building. Every person that is using the facility in the specific area that you have rented is directly under your responsibility. A coordinated and orderly evacuation is required immediately upon hearing the fire alarm or smoke detector.
AutoNDA by SimpleDocs
Fire Alarm System. Test and Inspect 100% of all fire alarm system components each calendar year to include, but not be limited to, the following:
Fire Alarm System. The base building Fire Alarm System is comprised of Strobes with audible speakers, (not horns) The fire control panels are of Siemens design and Cerberus system 3. Fire alarm devices to have white housings with red lettering. The Landlords alarm contractor must perform any connections to base building fire alarm panels ( expander panels excluded) Light Fixtures:
Fire Alarm System. The Contractor or Electrician shall furnish electrical drawings to Management Office prior to the commencement of construction. These drawings shall include Fire Alarm System (which should be a separate drawing), Riser Diagram and Sequence of Events. The Contractor is responsible for coordinating all work with Management Office. The Building’s Fire Panel contractor, Xxxxxx’x, shall make the final tie-in of all fire devices to the panel on the respective floor(s) at the Contractor’s expense. It is the responsibility of the Contractor to ensure that any devices installed be Building Standard and further, that any strobes/horns moved remain on the same circuit to ensure that the system remains in sync. In the event that the moving of horns/strobes causes the system to be out of sync, it will be the responsibility of the Contractor, as its sole expense, to correct the problem. A work permit must be obtained prior to any work on the fire alarm system from the Town of Watertown. The engineer who designed the mechanical systems shall sign and seal the riser plan and certify, in writing, the completed system to the Town of Watertown prior to the final sign off of the work permit and/or issuance of the Certificate of Occupancy. Also, the electrical contractor shall complete an A433R Form which certifies the correct installation of the fire alarm devices. The signed and sealed plan and A433R Form must be given to the Xxxx Management Office to complete the fire alarm filing and sign-off.
Fire Alarm System. When Tenant’s Work interferes with the fire alarm system wiring, connections to this system must be performed by or under the direct supervision of the Building engineers or its designated representatives. The Tenant or its general contractor must contact the Project Manager prior approval to commencing such activity. If system is activated and false alarm is signaled, Tenant will be charged $1000.00 for each event.
Fire Alarm System. The fire alarm system will continue to operate as is for now, which is to notify City staff of any fire notification for 00 Xxxxx Xxxxxx Xxxxxx. The City agrees that YSS staff should be added as a contact for the fire notifications at 24 and 00 Xxxxx Xxxxxx Xxxxxx, as the buildings are physically attached. YSS will pay one-third the yearly cost for monitoring and testing of the system. This will be xxxx annually. In the future, if the alarm system at the Property needs to be upgraded due to the occupancy status of the building, YSS will be responsible for that upgrade, with a decision to keep the systems connected to be made at that point in time.
Fire Alarm System. Landlord will provide a fire alarm system including a central command center, pull stations, voice communication systems, area and duct detectors (for applicable base building HVAC units larger than 2000 cfm equipment), sprinkler tie in, speakers and strobes at locations and quantities as required by code in core areas of the building. Fire command center will be located in main lobby and will provide the stair pressurization smoke control panel. The tenant, at their cost, shall tie into the system on each floor for required coverage within their respective spaces.
AutoNDA by SimpleDocs
Fire Alarm System. A. The Fire Safety System shall be a micro-processor based, network oriented, addressable multiplexed stand-alone fire alarm initiating device monitoring and supervising system and life safety type voice alarm annunciation system. The system design shall comply with NFPA, American Disabilities Act and local requirements. System monitoring, communication and signals shall be over two (2) wire plenum rated, shielded twisted pair circuits. The Shoppes at Springfield Commons Tenant’s Criteria Manual
Fire Alarm System. (a) Landlord has provided a Class C fire alarm system on each floor connected back to a central fire alarm panel located in the main lobby.
Fire Alarm System. None, unless required by law to complete Landlord’s work contained herein.