Facility Equipment Sample Clauses

Facility Equipment. Utility required circuit breaker coordination studies are not assumed for this project. A short-circuit coordination study is not included for this project. Solar system includes all standard interconnection related equipment on the Customer side of the meter, including panel circuit breakers, utility and/or visible utility lockable disconnect switches, solar metering, conduit, and wiring. Additional Customer-side protection required by the utilities above that provided by the certified inverters is not included. If harmonic data of the site is not available, Provider shall assume that the Harmonic data are within the acceptable limits of the Institute for Electrical and Electronics Engineers (IEEE) Standard 519. Soils and Structural Foundations Foundation assumptions are as follows for system options: • Drilled cast-in-place, 30” round caisson, 12’ Deep, approximately 2.5’ above grade, depending on existing topography. • Requirements for dewatering, sub grade rock removal, or other unforeseen conditions are not included. Canopy Structure Design Carport Canopies are at 10 degree tilt with 11 ft clear height. Roof Conditions Provider assumes no upgrading of the building structures or canopies will be required to support the added live and dead loads from the photovoltaic installation and rooftop equipment, or to resist added lateral or seismic loads. Modifications to the roof system and design and construction of supports, upgrades to the building structure or platforms are not included. Anchor and ballast counts are based on the wind load gradient method developed by Xxxxxx Xxxxxxx Xxxxxxxx, Inc, (CPP) and SunPower, based on the CPP wind tunnel testing results presented in CPP’s report “CPP7979_SunPowerEWSystem_REP_SOL_R08” dated May 17th, 2018. Increased anchor and ballast counts resulting from other design methods will be the responsibility of the client. Site Name Anchor Count 30 Xxxx 71 595 center 27 50 Xxxxxxx 90 1000 Xxxx 170 597 Center 33 Provider is not responsible for normal wear and tear associated with the installation of the solar system. Provider reserves the right to inspect the roof to verify its condition. In addition, Provider may offer recommendations to the Customer on modifications to the roof system to improve its serviceability. Customer is responsible for any and all modifications to the roof system. Modifications of roof systems fall into four categories: • Modifications to improve roof condition / serviceability / useful life. • Mo...
AutoNDA by SimpleDocs
Facility Equipment. 1. Through the statewide Set-Aside Funds, to maintain, or cause to be maintained, listed Facility equipment.
Facility Equipment. All of Borrower's right, title and interest (including any residual interest) in and to the Facility Equipment.
Facility Equipment. To the extent any Facility equipment is used in connection with the transport of patients, Transporter agrees to assume reasonable responsibility for such equipment during the transport. Transporter further agrees to return such equipment to Facility as soon as practicable following such transport. Notwithstanding anything in this Agreement to the contrary, Transporter shall not be liable to Facility for damage to or destruction of such equipment, unless such damage or destruction is the result of gross negligence or willful misconduct on the part of Transporter.
Facility Equipment. All of Borrower's right, title and interest (including any residual interest) in and to the Facility Equipment, whatever its condition, insured status, lien status, location, or relationship to an Eligible Contract.
Facility Equipment. The County and/or XXX will request Three Million, Five Hundred Thousand Dollars ($3,500,000) in grant funds from the Virginia Coalfield Economic Development Authority (VACEDA) to initially equip the facility and its outreach clinics with CODA approved and acceptable dental equipment. Should these funds not be available or adequate to meet the costs set forth in the initial budget, the County and the XXX will seek other alternative funding sources to meet this obligation. The equipment shall at least meet all CODA requirements, and the final decision as to the quantity and quality of such equipment to be procured shall lie with the XXX upon approval from CODA. Subsequent equipment replacements and upgrades shall become an expense of the Dental School budget as selected and procured by the Dental School, as long as such purchases are made upon an affordable and business- like basis to procure the quality and quantity of equipment necessary to provide a CODA-approved education to the Dental School students. Purchases of “top-end” or experimental equipment during the first Seven (7) fiscal years of operation (through fiscal year 2018-19) shall be done made only when based upon written justification provided by the Dental School leadership and pre- approved by the College and IDADental School’s board of directors and XXX. This clause is adopted in order to maintain budget integrity and in keeping with the Dental School’s mission to provide a quality education to mostly primary care dentists to serve underserved areas of central Appalachia, the Tobacco Commission Footprint and other areas of the nation as fulfillment of the Dental School’s primary mission is gradually realized.
Facility Equipment. Sportplex Adventure Room: • Table and chairs are provided for both adults and children for 20 max. • Private washroom • Counter space and sink • Children’s toys and equipment are not included in the rental of this room. Sportsplex Conference Room: • Table and chairs for 35 max. • Drop down screen • White board • Counter space and sink are available • TV • Projector and internet available upon request. Arena Meeting Room: • Table and chairs for 10. • Any special requirements please contact the facility staff to discuss.
AutoNDA by SimpleDocs
Facility Equipment. 3.1 The RMT providing the Service from a clinic shall:
Facility Equipment. All equipment, fixtures and machinery used in the operation or maintenance of the Facility.
Facility Equipment. Facility shall be responsible for obtaining, maintaining and protecting the security of any information technology infrastructure and equipment and ancillary services necessary for it to connect to, access or otherwise use the Platform and Services, including computers, software, hardware, servers, databases, operating systems, networks, data communications lines and the like (collectively, “Facility Equipment”).