Equipment Specification Sample Clauses

Equipment Specification any specification for the Equipment, including any relevant plans or drawings, that is agreed in writing by the Customer and Service Provider;
AutoNDA by SimpleDocs
Equipment Specification. All equipment shall be new, unused and substantially recyclable.
Equipment Specification. 6.1 The provider will: • ensure that all equipment used complies with national equipment standards, has been approved for use in the programme and is tested routinely by appropriately trained staff and medical physics services, in accordance with NHSBSP guidelines • ensure that all mammography x-ray systems used in the screening programme are full field direct digital mammography systems, are accredited for use within the NHSBSP and that image quality and radiation dose meet acceptable standards • full-field direct digital mammography is the only modality used for routine screening. MRI may be used for higher-risk women according to NHSBSP protocols. • MRI screening is only carried out by services that meet the MRI technical guidelines developed by the NHSBSP
Equipment Specification. Capacity 1400 lb Speed 30 FPM Nominal Drive 1:2 Roped Hydraulic Landing Entrances Two-speed Sliding Car Entrances Two-speed Sliding Car Lighting Four Recessed Pot Style Lights Battery Lowering Standard Manual Lowering Standard Power Supply 208v, 3 Phase, 60hz Stops Two Stop Travel 288" Pit Depth 14" Car Type Same Side Entry Car Size 48" x 54" Cab Finish White Laminate Car Ceiling White, Textured Cab Grab Rail Stainless Steel Finish Keyed Car Controls Not Included Keyed Call Stations Not Included Emergency Telephone Hands-Free Phone Installed in Cab Operating Panel Phase 1 Fire Service Not Included Warranty Two year parts, one year labor Extended Warranty Not Included Preventative Maintenance Plan 2 year PMP Included Please see Addendum A for optional items if included in this quotation/agreement.
Equipment Specification. The minimum specification required: Centrifuge for the processing of microtitre plates fully integratable into the automation platform with a maximum centrifugal force of at least 1000 x g, a capacity of at least 250 g and a maximum plate height of at least 45 mm. The centrifuge must be able to run with a minimum centrifugal force of no more than 100 x g.
Equipment Specification. All raw data sets gathered at each site, full presentation of results and findings. • Diary of events at each site. • Lessons learnt. • Recommendations. • Literature sources consulted. The format of the report should be as follows; • 4 paper copies of the report and associated appendices • A PDF of the report including all associated files and other outputs • An electronic version of the data in suitable format • Metadata entries for the report and the relevant raw data files/folders, generated using the BEEMS Metadata Creator Tool (provided by Cefas).
Equipment Specification. Model GVL-EN-144 Capacity 750 lbs Speed 9 FPM (Lead Screw Drive) Drive Mechanism Lead Screw Depth of Pit 0" (No pit), Ramp Required Safety Devices As Required by Code Keyed Car Controls Not Included Keyed Landings Control Included Platform Size 36" X 54" Platform Type Through Platform Courtesy + Emergency Lighting Standard Number of Stops Two Stop Battery Backup (Up and Down) Not Included Manual Lowering Standard Emergency Stop/Alarm Standard Lower Landing Entrance 3’0” x 6’8” Non-Rated Door Assembly w/ steel panel (frame, closer, hardware) Mid Landing Entrance No Mid Landing Upper Landing Entrance 3’0” x 6’8” Non-Rated Door Assembly w/ steel panel (frame, closer, hardware) Ramp Included Split Mast Kit Not included Car Grab Rail Standard Warranty Two year parts, one year labor Phone Not Included Preventative Maintenance Plan 1 Year PMP Included Please see Addendum A for optional items if included in this quotation/agreement.
AutoNDA by SimpleDocs

Related to Equipment Specification

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. Items Offered as New. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Product Specifications The Company agrees that all Products sold to Xxxx hereunder shall conform to the respective specifications set forth on Schedule A or to such other specifications as are from time to time agreed upon by the Parties.

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Technical Specifications 1. A procuring entity shall not prepare, adopt or apply any technical specification or prescribe any conformity assessment procedure with the purpose or effect of creating an unnecessary obstacle to trade between the Parties.

  • Class Specifications The Human Resources Division shall determine:

Time is Money Join Law Insider Premium to draft better contracts faster.