Electrical Distribution Sample Clauses

Electrical Distribution. Electrical distribution for systems furnishings office areas shall be through covered wireway(s) above the acoustic ceiling or through the perimeter walls of the space. Electrical wiring shall be enclosed in metallic raceways with junction boxes. Each junction box is to contain the 8 wires to be compatible with the State’s systems furnishings. The grid is to include a 12’ Greenfield drop at each junction box.. A raceway shall be provided for telephone/data cabling of sufficient size to accommodate three 4-pair, category 5, twisted pair cable to each office, conference room and systems furnishings workstation. This raceway shall originate in the Tele/Data room and shall run parallel to the electrical distribution raceway.
AutoNDA by SimpleDocs
Electrical Distribution. This test will ensure that all equipment, breakers, transformers, bus duct, and major cable runs, are operating within their rated capacity. The system will be checked for no hot spots. Transfer of loads will also be tested along with demonstration of UPS performance against design. Load shedding will also be confirmed.
Electrical Distribution. Electrical distribution for open office areas shall be through covered wireway(s) above the ceiling. Electrical wiring shall be enclosed as required by code, with junction boxes spaced on a 15’x15’ grid. Each junction box is to contain the eight wires to be compatible with the Xxxxxxx Power Base furniture. The grid is to include a twelve foot greenfield drop at each junction box on the 15’x15’ grid. Each drop is to contain three dedicated circuits with separate neutrals for each circuit: one isolated ground circuit and two circuits with a common ground. Open office area includes all work spaces where more than one employee is stationed. Space and conduit (if required) shall be provided for telephone/data cabling of sufficient size to accommodate three four-pair, level 5, twisted pair cable to each office, conference room and modular furniture workstation. This raceway shall originate in the Tele/Data room and shall run parallel to the electrical distribution raceway.
Electrical Distribution. All electrical wiring from the distribution breaker panel shall be via rigid metal conduit, thin wall, routed along the under side of the cable tray to a point directly above the equipment rack. From this point, TRITON may select how to distribute to its equipment or rack.
Electrical Distribution. 1. Existing Distribution serving the tenant space is a 277/480V 3 phase 4 wire system supplied from a base building electrical switchboard. Step-down to 120/208V local power panels are through dry type transformers 480 primary 120/208V secondary.
Electrical Distribution. A. The electrical distribution in the building shall be as required to provide power for the mechanical systems and other various systems.
Electrical Distribution. A. The following requirements only apply to the last demarcation point of landlord supplied power (the “Landlord/Customer Demarcation Point”). Demarcation is the output power of the Power Distribution Unit (PDU).
AutoNDA by SimpleDocs
Electrical Distribution. Electrical distribution for systems furnishings office areas shall be through covered wireway(s) above the acoustic ceiling or through the perimeter walls of the space. Electrical wiring shall be enclosed in metallic raceways with junction boxes spaced on a 15’ x 15’ grid. Each junction box is to contain the 8 wires to be compatible with the State’s systems furnishings. The grid is to include a 12’ Greenfield drop at each junction box on the 15’ x 15’ grid. A raceway shall be provided for telephone/data cabling of sufficient size to accommodate three 4-pair, category 5, twisted pair cable to each office, conference room and systems furnishings workstation. This raceway shall originate in the Tele/Data room and shall run parallel to the electrical distribution raceway.
Electrical Distribution. The electrical network available for the equipment at 208VAC is composed of circuits segmented by sectored boards that distribute power to the plug strips for each rack or equipment. Each circuit is individually protected by a circuit breaker and short-circuit detector.
Electrical Distribution. The Landlord will provide enough circuits on the electric distribution panel in the electrical room to connect up to 5 xxxxx per square foot of usable space for lighting and general purposes.