Cutting Pipe Sample Clauses

Cutting Pipe. Any pipe which must necessarily be cut on the job in order to put fittings, valves or other accessories in the proper place shall be done in a workmanlike manner satisfactory to the District. In case of “push-on” joint pipe, proper chamfering must be done on the ends of any cut pipe before an attempt is made to enter it into a xxxx. In the case of mechanical joints, a smooth, square, neat cut must be made. On Ductile iron pipe a saw or abrasive wheel type of equipment shall be used. On cast iron pipe smaller than 12”, wheel cutters or other approved method may be used, but in no case shall any cement lining of iron pipe be harmed in the cutting. No so-called “cold cutters” will be allowed on the job. All cuts shall be square and even, with no ragged, rough ends. Any unevenness shall be ground smooth. Pipe shall be cut no closer than 2’ from the xxxx.
AutoNDA by SimpleDocs
Cutting Pipe. The Contractor shall cut the pipe and bevel the end, as necessary, to provide the correct length of pipe necessary for installing the fittings, valves, accessories and closure pieces in the correct location. Only push-on or mechanical joint pipe shall be cut. Cement lining shall be undamaged.
Cutting Pipe. Wherever the pipe requires cutting to fit into the line, the work shall be done in a satisfactory manner so as to leave a smooth end at right angles to the axis of the pipe. Pipe shall be cut and beveled to manufacturer’s recommended tolerances. When a piece of pipe is cut to fit into the line, no payment shall be made for the portion cut off and not used in the line. Joints on existing piping will be carefully cut and any breakage will be at the sole expense of the Contractor.

Related to Cutting Pipe

  • Excavation If an excavation shall be made upon land adjacent to the Leased Premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the Leased Premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which the Leased Premises form a part from injury or damage and to support the same by proper foundation, without any claim for damages or indemnity from Landlord, or diminution or abatement of Rent.

  • Basement Any leaks or evidence of moisture? Yes No Unknown Does Not Apply Comments:

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Clearcutting Units All trees that meet Utilization Standards within “Clearcutting Units” are designated for cutting.

  • Dedicated Transport A DS0-, DS1-, or DS3-capacity transmission facility between Verizon switches (as identified in the LERG) or UNE Wire Centers, within a LATA, that is dedicated to a particular end user or carrier. Dedicated Transport is sometimes referred to as dedicated interoffice facilities ("IOF"). Dedicated Transport does not include any facility that does not connect a pair of Verizon UNE Wire Centers.

  • FABRICATION Making up data or results and recording or reporting them.

  • ADJACENT EXCAVATION-SHORING 32. If an excavation shall be made upon land adjacent to the demised premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the demised premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which demised premises form a part from injury or damage and to support the same by proper foundations without any claim for damages or indemnity against Owner, or diminution or abatement of rent.

  • Project Site The “Project Site” is the place where the Work is being carried on.

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • Meters 7.1.1 For installation of Meters, Meter testing, Meter calibration and Meter reading and all matters incidental thereto, the SPD and SECI shall follow and be bound by the Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006, the Grid Code, as amended and revised from time to time.

Time is Money Join Law Insider Premium to draft better contracts faster.