Correction of Metering Errors Sample Clauses
POPULAR SAMPLE Copied 1 times
Correction of Metering Errors. If, upon any test, and measuring equipment is found to be in error, such that the resultant aggregate error in the computed volumes of Gas and quantities of energy received or delivered does not exceed plus or minus two percent (+/- 2%), such errors may be taken into account in a practical manner in computing the volume of Gas and quantities of energy received or delivered. All equipment shall, in any case, be adjusted at the time of test to record correctly. If, however, the resultant aggregate error in the computed volumes of Gas and quantities of energy received or delivered exceeds +/- 2%, previous recordings of such equipment, and the corresponding volumes of Gas and quantities of energy received or delivered, shall be corrected to zero error for any period which is known definitely or agreed upon, but in case the period is not known definitely or agreed upon, such correction shall be for a period extending over one half of the time elapsed since the date of the last test.
Correction of Metering Errors. If, upon any test, the measuring equipment, in the aggregate for any measurement facility, is found to be inaccurate by more than two percent (2%) (one percent [1%] if electronic flow measurement equipment is utilized), registration thereof and any payments based upon such registration shall be corrected at the rate of such inaccuracy for any period of inaccuracy which is definitely known or agreed upon; provided, however, if such period is not definitely known or agreed upon, then such registration and payment shall be corrected for a period extending back one-half (1/2) of the time elapsed since the last day of calibration.
Correction of Metering Errors. If, upon test, the measuring equipment is found to be in error by not more than one percent (1%), previous recordings of such equipment shall be considered accurate in computing deliveries, but such equipment shall be adjusted at once to record accurately. If, upon test, the measuring equipment shall be found to be inaccurate by an amount exceeding one percent (1%), at a recording corresponding to the average Hourly rate of flow for the period since the last preceding test, then any previous recordings of such equipment shall be corrected to zero error for any period that is known definitely or agreed upon between ELC and Customer. In case the period is not known or agreed upon by ELC and Customer, such correction shall be for a period equal to one-half of the time elapsed since the date of the last undisputed test.
Correction of Metering Errors. If, upon testing, the measuring equipment is found to be in error by not more than one percent (1.0%), previous recordings of such equipment shall be considered accurate in computing deliveries, but such equipment shall be adjusted at once to record accurately. If, upon test, the measuring equipment shall be found to be inaccurate by an amount exceeding one percent (1.0%) at a recording corresponding to the average hourly rate of flow for the period since the last preceding test, then any previous recordings of such equipment shall be corrected to zero error for any period that is definitely known or agreed upon. In case the period is not definitely known or agreed upon, such correction shall be for a period equal to one-half of the time elapsed since the date of the last test.
Correction of Metering Errors. Upon any test, if the measuring equipment, in the aggregate for any measurement facility, is found to be inaccurate by more than 1% registration thereof, then any payments based upon such registration shall be corrected at the rate of such inaccuracy for any period of inaccuracy that is definitely known or agreed upon. If such period is not definitely known or agreed upon, then such registration and payment shall be corrected for a period extending back one-half (1/2) of the time elapsed since the last day of calibration.
Correction of Metering Errors. If, upon test, the measuring equipment is found to be in error by not more than one percent (1%), previous recordings of such equipment shall be considered accurate in computing deliveries, but such equipment shall be adjusted at once to record accurately. If, upon test, the measuring equipment shall be found to be inaccurate by an amount exceeding one percent (1%), at a recording corresponding to the average Hourly rate of flow for the period since the last preceding test, then any previous recordings of such equipment shall be corrected to zero error for any period that is known definitely or agreed upon between Transporter and Shipper/Operator. In case the period is not known or agreed upon by Transporter and Shipper/Operator, such correction shall be for a period equal to one-half of the time elapsed since the date of the last test.
Correction of Metering Errors. 16 6.5 Low Volume Meter Fee ............................................................................................. 16 6.6
Correction of Metering Errors. (a) If, upon test, the measuring equipment is found to be in error by not more than 2%, previous recordings of such equipment shall be considered accurate in computing deliveries, but such equipment shall be adjusted at once to record accurately within the manufacturer's specifications.
(b) If, upon test, the measuring equipment shall be found to be in error by more than 2%, then any previous recordings of such equipment shall be corrected to zero error for any period that is known definitely or agreed upon. In case the period is not known or agreed upon, such correction shall be for a period equal one-half of the time elapsed since the date of the last test.
(c) When Shipper installs compression facilities upstream of Gatherer's metering facilities, delivery by Shipper of Natural Gas shall not exceed 120o F (degrees Fahrenheit) and shall be made in a manner that will prevent pulsation from interfering with Gatherer's measurement of said Natural Gas.
(d) If Shipper installs such compression facilities, Shipper shall be liable for, shall indemnify, and shall hold Gatherer harmless against all claims and causes of action for injuries to or death of persons (including agents, employees, and representatives of Gatherer) and damages to any property (including property of Gatherer, its agents, employees, and representatives) resulting from the installation, operation, maintenance, or removal of such compression facilities, unless such claims were the result of negligence or intentional misconduct of Gatherer.
(e) If a metering error is identified by Gatherer or Shipper, such error shall be adjusted; provided, however, that any claim for adjustment must be made within 12 months from the date of production being measured.
Correction of Metering Errors. If any measuring equipment is found to be inaccurate, the equipment will be adjusted immediately to measure accurately. If the measuring equipment in the aggregate is found to be inaccurate by one percent or more at a recording corresponding to the average hourly rate of gas flow for the period since the last preceding test, any payments based upon inaccurate measurement will be corrected at the rate of the inaccuracy for any period that is known definitely or agreed upon, but in case the period is not known definitely or agreed upon, the correction shall be for a period extending over one half of the time elapsed since the date of the last test