Cooling Water Clause Samples

The Cooling Water clause defines the requirements and responsibilities related to the supply, use, and quality of water used for cooling purposes in a facility or industrial process. Typically, this clause specifies the source of the cooling water, acceptable temperature and purity standards, and the party responsible for providing or maintaining the water supply. For example, it may require the facility operator to ensure that cooling water is free from contaminants that could damage equipment or affect process efficiency. The core function of this clause is to ensure reliable and safe operation of cooling systems by clearly allocating responsibility and setting standards for the cooling water used.
Cooling Water. The variable component is based on actual yields and prices of raw water, chemicals and utilities (see Appendix 3). • The Fixed Component, • The User Charge
Cooling Water. The User will have access to up to 2m3/second of cooling water from the Baltic Sea. The access point will be agreed between the Parties. The User need to construct the connectivity to the cooling water on the Users own expense. The drawing for the connectivity needs to be approved by the Provider before work is commenced.
Cooling Water. Seller shall have no obligation to provide cooling water to Buyer
Cooling Water. ▇▇▇▇▇ shall provide approximately 15,540 gpm of cooling water to the Facility's battery limits. The cooling water typically has the following constituents at 10 cycles of concentration: =================================================================== Characteristics Minimum Normal Maximum ------------------------------------------------------------------- Feed Water pH 7.2 ------------------------------------------------------------------- Temperature (degrees)F 93 93 ------------------------------------------------------------------- Calcium Hardness as CaCO(3) ppm 82 ------------------------------------------------------------------- Magnesium Hardness as CaCO(3) ppm 50 ------------------------------------------------------------------- Total Hardness as CaCO(3) ppm 115 ------------------------------------------------------------------- Sodium as Na ppm 78 ------------------------------------------------------------------- Potassium as K mg/L ------------------------------------------------------------------- Iron as Fe ppm 6.0 ------------------------------------------------------------------- Manganese as Mn mg/L ------------------------------------------------------------------- Copper as Cu ppm 0.23 ------------------------------------------------------------------- Aluminum as Al mg/L ------------------------------------------------------------------- Zinc as Zn mg/L ------------------------------------------------------------------- Ammonia and Ammonium Ion as NH(3) mg/L ------------------------------------------------------------------- Methyl Orange (M) Alkalinity as CaCO(3) ppm 56 ------------------------------------------------------------------- Phenolphahalein (P) Alkalinity as CaCO(3) ppm 0 ------------------------------------------------------------------- Chloride as Cl ppm 295 ------------------------------------------------------------------- Sulfate as SO(4) mg/L ------------------------------------------------------------------- Nitrate as NO(4) mg/L ------------------------------------------------------------------- Orthophosphate as PO(4) ppm 32 ------------------------------------------------------------------- Total Phosphate as P0(4) mg/L ------------------------------------------------------------------- Silica as SiO(2) ppm 88 ------------------------------------------------------------------- Total Dissolved Solids, TDS mg/L ------------------------------------------------------------------- Total Suspended Solids, TSS mg/L ...
Cooling Water. Lessor shall, at no cost to Lessee, supply all cooling water requested by Lessee from time to time, up to 500 gallons per minute (“gpm”) for use at the Leased Premises. Lessor shall also accept the return from Lessee of cooling water. Lessee shall be responsible for all costs associated with constructing and maintaining the interconnection points for the transfer of the cooling water and cooling water return. Such supply interconnection point shall be located at RAC/WAS Pump Station 1 (B-116), and the return interconnection shall be at either the Plant Decant Station #1 or Plant 1 RAS/WAS Pump Station B-51 along the South Access Road.