CONTROL CUBICLES Clause Samples

CONTROL CUBICLES. All cubicles shall be of approved design and construction with rigid front panels and with back of panel doors hinged to lie flat. The hinges shall be of the lift-off type. The cubicles shall be totally enclosed, dust proof, vermin proof and adequately ventilated to prevent condensation. The outside of the cubicles shall be finished in an approved colour. The inside of the cubicles shall be finished white. Control panels may contain more than one circuit, in which case each circuit must be segregated and the terminal boards labelled with main circuit designation. Each panel shall be provided with a 240 V bayonet cap, internal illuminating lamp operated from a door switch. Separate gland plates shall be provided for each circuit complete with glands suitable for PVC/ SWA/ PVC cable.

Related to CONTROL CUBICLES

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Special Equipment The Employer agrees to provide specialty tools, emergency supplies/equipment, testing equipment and safety equipment as needed to perform required duties as determined and authorized by the Chief or designee. The emergency supplies/equipment will include appropriate survival provisions and equipment for each permanent Maintenance Mechanic 4 and the Law Enforcement Communications Systems Supervisor when they are performing duties that would require such provisions and equipment. When necessary, the employer will replenish used or expired survival provisions and damaged and unusable equipment. All supplies and equipment will be returned to the employer when the employee is no longer performing the duties that would require the survival provisions and/or equipment.

  • Workstation/Laptop encryption All workstations and laptops that process and/or store County PHI or PI must be encrypted using a FIPS 140-2 certified algorithm which is 128bit or higher, such as Advanced Encryption Standard (AES). The encryption solution must be full disk unless approved by the County Information Security Office.

  • Capital Equipment Collaborator’s commitment, if any, to provide ICD with capital equipment to enable the research and development activities under the Research Plan appears in Appendix B. If Collaborator transfers to ICD the capital equipment or provides funds for ICD to purchase it, then ICD will own the equipment. If Collaborator loans capital equipment to ICD for use during the CRADA, Collaborator will be responsible for paying all costs and fees associated with the transport, installation, maintenance, repair, removal, or disposal of the equipment, and ICD will not be liable for any damage to the equipment.

  • Cell Phones The College follows the State’s Cell Phone Policy. Employees who receive cell phones from the College shall also abide by this Policy. The College shall provide the Policy to any employee who is given a cell phone. Employees are responsible for the cost of all personal calls. While the College anticipates some incidental personal use of cell phones, it is also expected that such use is infrequent.