Compliance Demonstration Methods. Each month the permittee shall calculate the total emissions of each hazardous air pollutant from the facility regulated by the Clean Air Act as follows:69 [s. NR 407.09(4)(a)1., Wis. Adm. Code] Ex = (1 ton/2000 lbs) x {[(U1 x W1 x H1 x F1) + (U2 x W2 x H2 x F2) + ... + (Un x Wn x Hn x Fn)] - [(S1 x I1) + (S2 x I2) + ... + (Sm x Im)]} where: Ex is the monthly emissions of each hazardous air pollutant regulated by the Clean Air Act (tons/month); x identifies each HAP emitted from the facility U is the monthly usage of each ink, coating, solvent, or other HAP containing material used during the month (gallons/month); W is the density of each ink, coating, solvent, or other HAP containing material used during the month (pounds/gallon) H is the HAP content of each ink, coating, solvent, or other HAP containing material used during the month expressed as a weight fraction (i.e. if a material is 25% HAP by weight H would be 0.25); F is a multiplier for HAP containing materials for which the HAP is emitted at other than 100% of its content. For those HAP containing materials for which the HAP is 100% emitted, F equals 1 and does not have to be specifically considered in the equation.; n identifies each ink, coating, solvent or other HAP containing material used during the month; S is the amount of each spent ink, coating, solvent or other HAP containing material recovered and shipped off site each month (gallons/month); I is the HAP content of each spent ink, coating, solvent or other HAP containing material recovered and shipped off site each month in pounds per gallon; m identifies each spent ink, coating, solvent or other HAP containing material recovered and shipped off site during the month.
Appears in 1 contract
Compliance Demonstration Methods. (1) Each month the permittee shall calculate the total emissions of each hazardous air pollutant from the facility regulated by the Clean Air Act as follows:69 [s. NR 407.09(4)(a)1., Wis. Adm. Code] follows:1 Ex = (1 ton/2000 lbs) x {[(U1 x W1 x H1 x F1) + (U2 x W2 x H2 x F2) + ... + (Un x Wn x Hn x Fn)] - [(S1 x I1) + (S2 x I2) + ... + (Sm x Im)]} where: Ex is the monthly emissions of each hazardous air pollutant regulated by the Clean Air Act (tons/month); x identifies each HAP emitted from the facility U is the monthly usage of each ink, coating, solvent, or other HAP containing material used during the month (gallons/month); W is the density of each ink, coating, solvent, or other HAP containing material used during the month (pounds/gallon) 1 This calculation shall be performed for each hazardous air pollutant regulated by the Clean Air Act that is emitted from the facility. H is the HAP content of each ink, coating, solvent, or other HAP containing material used during the month expressed as a weight fraction (i.e. if a material is 25% HAP by weight H would be 0.25); F is a multiplier mulltiplier for HAP containing materials for which the HAP is emitted at other than 100% of its content. For those HAP containing materials for which the HAP is 100% emitted, F equals 1 and does not have to be specifically considered in the equation.; n identifies each ink, coating, solvent or other HAP containing material used during the month; S is the amount of each spent ink, coating, solvent or other HAP containing material recovered and shipped off site each month (gallons/month); I is the HAP content of each spent ink, coating, solvent or other HAP containing material recovered and shipped off site each month in pounds per gallon; m identifies each spent ink, coating, solvent or other HAP containing material recovered and shipped off site during the month. [s. NR 407.09(4)(a)1., Wis. Adm. Code]
(2) To demonstrate compliance with condition I.A.2.a.(1), the permittee shall calculate the emissions of each hazardous air pollutant regulated by the Clean Air Act over each 12 consecutive month period by summing the monthly emissions of each hazardous air pollutant regulated by the Clean Air Act as calculated in I.A.2.b.(1) for each consecutive 12 month period. This calculation shall be performed within twenty calendar days of the end of each month for the previous 12 consecutive month period. [s. NR 407.09(4)(a)1., Wis. Adm. Code]
(3) Each month the permittee shall calculate the total emissions of hazardous air pollutants regulated by the Clean Air Act as follows: Ehap = Σ Ex where: Ehap is the monthly total emissions of all hazardous air pollutants regulated by the Clean Air Act that are emitted by the facility (tons/month); Ex is the monthly emissions of each hazardous air pollutant regulated by the Clean Air Act (tons/month) as calculated in I.A.2.b.(1); x identifies each HAP emitted from the facility. [s. NR 407.09(4)(a)1., Wis. Adm. Code]
(4) To demonstrate compliance with condition I.A.2.a.(2), the permittee shall calculate the total emissions of all hazardous air pollutants regulated by the Clean Air Act over each 12 consecutive month period by summing the monthly emissions of all hazardous air pollutants regulated by the Clean Air Act as calculated in I.A.2.b.(3) for each consecutive 12 month period. This calculation shall be performed within twenty calendar days of the end of each month for the previous 12 consecutive month period. [s. NR 407.09(4)(a)1., Wis. Adm. Code]
(5) The permittee shall use coating manufacturer's formulation data to determine the HAP content (Hn) of the of the inks, coatings, solvents or other HAP containing materials used. [s. NR 439.04(1)(d), Wis. Adm. Code]
(6) The permittee shall analyze the spent ink, coating, solvent and other HAP containing material recovered and shipped off site to determine the HAP content (H) no less than: (a) each time there is a substantial change to materials or process operations that may affect the characteristics of the waste stream; or (b) quarterly, which ever is most frequent. [s. NR 439.04(1)(d), Wis. Adm. Code]
Appears in 1 contract