Common use of Check Meter Clause in Contracts

Check Meter. Buyer may, at its sole cost, furnish and install one Check Meter on the high voltage side of the substation associated with the Generating Facility or, if there is not enough space at such substation to install the Check Meter, any other location mutually agreeable to the Parties. The Check Meter shall be interconnected with Buyer’s communication network to permit (i) periodic, remote collection of revenue quality meter data, and (ii) back-up real time transmission of operating-quality meter data through the Telemetry System. Buyer shall test and recalibrate the Check Meter at least once every Term Year. The Check Meter will be locked or sealed, and the lock or seal may only be broken by a Buyer representative. Seller has the right to be present whenever such lock or seal is broken. Buyer shall replace the Check Meter battery at least once every 36 months; provided, however, if the Check Meter battery fails, Buyer shall promptly replace such battery.

Appears in 7 contracts

Samples: Power Purchase and Sale Agreement, Power Purchase and Sale Agreement, Power Purchase and Sale Agreement

AutoNDA by SimpleDocs

Check Meter. Buyer may, at its sole cost, furnish and install one or more Check Meter Meters, as applicable, on the high voltage side of the substation associated with the Generating Facility or, if there is not enough space at such substation to install the Check Meter, any other location mutually agreeable to the Parties. The Check Meter shall be interconnected with Buyer’s communication network to permit (i) periodic, remote collection of revenue quality meter data, and (ii) back-up real time transmission of operating-quality meter data through the Telemetry System. Buyer shall test and recalibrate the Check Meter at least once every Term Year. The Check Meter will be locked or sealed, and the lock or seal may only be broken by a Buyer representative. Seller has the right to be present whenever such lock or seal is broken. Buyer shall replace the Check Meter battery at least once every 36 months; provided, however, if the Check Meter battery fails, Buyer shall promptly replace such battery.

Appears in 6 contracts

Samples: Power Purchase and Sale Agreement, Power Purchase and Sale Agreement, Power Purchase and Sale Agreement

AutoNDA by SimpleDocs

Check Meter. Buyer may, at its sole cost, furnish and install one Check Meter on the high voltage side of the substation associated with the Generating Facility or, if there is not enough space at such substation to install the Check Meter, any other location mutually agreeable to the Parties. The Check Meter shall be interconnected with Buyer’s communication network to permit (i) periodicpermit: Periodic, remote collection of revenue quality meter data, ; and (ii) backBack-up real time transmission of operating-quality meter data through the Telemetry SystemSystem set forth in Section 3.09. Buyer shall test and recalibrate the Check Meter at least once every Term Year. The Check Meter will be locked or sealed, and the lock or seal may only shall be broken only by a Buyer representative. Seller has the right to be present whenever such lock or seal is broken. Buyer shall replace the Check Meter battery at least once every 36 thirty-six (36) months; provided, however, if the Check Meter battery fails, Buyer shall promptly replace such battery.

Appears in 2 contracts

Samples: Power Purchase and Sale Agreement, Power Purchase and Sale Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.