Cabling Connection Clause Samples

Cabling Connection a) BT or BT approved contractor is able to provide the cabling connection at the Site from the Customer’s Rack Space to the following destinations which are chargeable to the Customer: i. To the Site Meet-Me-Room (MMR), term as “Cross Connection from Hosted Rack to MMR” ii. To another Rack Space that is not adjacent to each other within same suite area, term as “Cross Connection Within Suite” iii. To another Rack Space in different suite within same or different floor, term as “Cross Connection between Suite” iv. To another Rack Space in different building within the Site compound that has ready inter building connections provisioned, term as “Inter-Building Cross Connection” b) Each standard cabling connection for above a(i), a(ii) and a(iii) come with 1 physical link with a backup link laid (1 active, 1 standby) which can be either UTP (CAT5/CAT6) or Single Mode with the following Service Level: i. Response Time: within 30 mins upon incident logged ii. Resolution Time: within 4 hours to replace faulty wiring. Any requirement for resolution time below 4 hours, the Customer requires to subscribe additional physical link for the relevant Cross Connection services and set up Active-Active design. c) For the Inter-Building Cross Connection in above a(iv), the link shall be provisioned with minimum 2 x 2 Core Single mode when order is requested. d) BT will schedule all overhead or under floor cabling work within the Site outside of Business Hours for operational and safety reasons. e) BT reserves the right to make an additional charge for any cabling work where as a result of a request or requirement by the Customer.
Cabling Connection a) BT or BT approved contractor is able to provide the cabling connection at the Site from the Customer’s Rack Space to the following destinations which are chargeable to the Customer: i. To the Site Meet-Me-Room (MMR), term as “Cross Connection from Hosted Rack to MMR” ii. To another Rack Space Each standard cabling connection for above a(i), a(ii) with 1 physical which can be either UTP (CAT5/CAT6) or Single Mode/Multi Mode Fiber. b) BT will schedule all overhead or under floor cabling work within the Site outside of Business Hours for operational and safety reasons. c) BT reserves the right to make an additional charge for any cabling work where as a result of a request or requirement by the Customer.

Related to Cabling Connection

  • Internet Connection Certain Solutions may require an active and stable connection to the Internet in order to function. It is therefore your responsibility to ensure that you have at all times an active and stable Internet connection.

  • Reconnection The Parties shall cooperate with each other to restore the Small Generating Facility, Interconnection Facilities, and the New York State Transmission System and Distribution System to their normal operating state as soon as reasonably practicable following a temporary disconnection.

  • Disconnection Upon termination of this Agreement, Developer and Connecting Transmission Owner will take all appropriate steps to disconnect the Developer’s Large Generating Facility from the New York State Transmission System. All costs required to effectuate such disconnection shall be borne by the terminating Party, unless such termination resulted from the non-terminating Party’s Default of this Agreement or such non-terminating Party otherwise is responsible for these costs under this Agreement.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If WCS chooses to subtend a Verizon access Tandem, WCS’s NPA/NXX must be assigned by WCS to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 WCS shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from WCS’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office WCS utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow WCS’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Electrical connections In accordance with paragraph 5.11. However, if a rear position lamp is reciprocally incorporated with a direction- indicator, the electrical connection of the rear position lamp on the relevant side of the vehicle or the reciprocally incorporated part of it may be such that it is switched OFF during the entire period (both ON and OFF cycle) of activation of the direction-indicator lamp.