Preliminary Design Plans Sample Clauses

Preliminary Design Plans. Xxxxxx will develop preliminary (approximate 30%) plans that provides the Airport and FAA with the new alignment of the fence and drainage structures for review and approval before providing full design for the budgeted amount. Preliminary plans shall include the following, please note that additional sheets will be provided at later submittals: • Cover Sheet • General Construction Notes (FAA and City of Pueblo) • Design Legend, Abbreviations and Sheet Index • Project Quantities Sheet • Project Site Plan • Contractor Staging and Storage Area – including the airport access location and contractor’s haul routeSurvey Control Sheet (establishment of survey control) • Construction Phasing and Barricade Plan • Stormwater Pollution Prevention Plan (SWPPP) • Fence Line and Grading Plans (20 Sheets) • Drainage Plans at Xxxxxx Crossings (12 Sheets) • Drainage Structure Details (6 Sheets) • Fence and Wildlife Gate Details (3 Sheets) • Pedestrian and Vehicle Access Gate Details • Geotechnical Boring Location Map • Boring Logs (5 Sheets) Estimated Total Sheet Count for Preliminary Submittal = 57 Total sheets
AutoNDA by SimpleDocs
Preliminary Design Plans. Engineer shall submit preliminary design plans for review and approval by the City. Preliminary plans must be approved by the City prior to Engineer commencing with the preparation of final design construction plans. Engineer shall prepare preliminary design plans at a horizontal scale of 1"=20' and a vertical scale of 1"=5' (horizontal scale of 1"=40' and a vertical scale of 1"=4' may be used with prior permission by the City) on 22" x 34" sheets. Preliminary design plans shall include the following:
Preliminary Design Plans. 1. No proposed additions to the Engineering Services Contract.
Preliminary Design Plans. CONSULTANT shall prepare preliminary design plans for the channel bank protection alternative which may include modular concrete block retaining walls or concrete riprap. Preliminary design plans will include a title sheet, demolition sheet, a project layout for proposed capital improvements, horizontal control sheet with proposed channel alignments, drainage area map, preliminary hydrologic and hydraulic calculations, preliminary plan and profile sheets for proposed channel improvements, conceptual channel wall cross sections, pavement repair/reclamation sheets and quantity sheets. Preliminary plans will be of sufficient detail for submission for franchise utility review. The requirements for preliminary plans will be in accordance with the City of Arlington Design Criteria Standards. An preliminary opinion of probable construction cost for proposed capital improvements will be submitted. The CONSULTANT will perform QA/QC of preliminary plans. A preliminary plans review meeting and project walkthrough with the OWNER will be conducted. Preliminary plans must be approved by OWNER prior to CONSULTANT commencing with the preparation of final design plans.
Preliminary Design Plans. The DISTRICT will complete preliminary design plans at the 30 percent design level including necessary information such as topography, land boundaries, and the location of utilities (both underground and aboveground). A recommended course of action for management of utilities will be provided. Estimates for pollutant load reductions (TSS, TN, TP, and metals) will be provided. A preliminary cost estimate will also be provided at this time. The DISTRICT will hold a design review meeting of the preliminary design phase and will provide a formal evaluation.
Preliminary Design Plans. The preliminary plans are to be prepared for the preferred overall alignment, selected after the Alternatives Evaluation Workshop, at 1" = 40' scale (or other scale as directed or approved by the City) and appropriate vertical scale. The plans will include the following items: • Cover Sheet • CNLV General NotesHorizontal Control • Sewer Plans and Profiles • Preliminary Grading Plans (all final grading design will be conducted post preliminary design level) • Detail Sheets Structural design will not be performed or included as part of the Preliminary Design. Deliverables: Preliminary Design plans (11” x 17”) will be included in the PDR.
AutoNDA by SimpleDocs
Preliminary Design Plans. Once Garver receives written approval on the final PDR presented to the Owner at the PDR Review Meeting, Garver will begin developing 30% plans. The preliminary set of plans will include gravity interceptor, forcemain, lift station design. The preliminary design phase will represent approximately 30 percent of final construction contract plans. This submittal will not include technical specifications or “front endcontract documents. This task includes the following:
Preliminary Design Plans. A description of those areas ("Program Space") within the Club that are proposed to be developed as a Program Facility, which description will identify, without limitation, any area (i) to be used to provide Program Services, (ii) required for conducting administrative tasks (including office space) and (iii) which will be a shared or common space within the Club.
Preliminary Design Plans. 30% DESIGN
Time is Money Join Law Insider Premium to draft better contracts faster.