Humidity Sample Clauses

Humidity. Humidity creates a significant risk to workers' health and safety. Consultation with workers must take place when humidity exceeds 75% to assess all risks associated with the work being performed. Things taken into account shall include: • Monitoring and improving air flow/ventilation; • The health/medical conditions of individual workers; • Rescheduling work so that tasks are performed in cooler, less humid parts of the day; • Job rotation to reduce the amount of direct exposure to humidity; • Provision of temporary shade and electric fans; • Scheduled hourly drink breaks of approximately 5-10 minutes in shade; • Provision of cool drinking water; • Provision of extra and regular work breaks in cooler areas (i.e. Air- conditioned site sheds); • Use of mechanical aids to reduce physical exertion; and • Adequate supervision.
AutoNDA by SimpleDocs
Humidity. The track shall be dry.
Humidity. Loss or damage caused by or consequent upon humidity in a Housing Unit that is not the direct result of a Defect.
Humidity. The road shall be dry.
Humidity. Goal: 80% of the period – 45-55% 15% of the period – 42-58% 5% of the period – 40-60% Fault: MEDIUM
Humidity. If the humidity inside any of Customer’s cages drops below twenty percent (20%) or exceeds sixty-five percent (65%) for more than fifteen (15) consecutive minutes (“Humidity Irregularities”) on two (2) or more separate days during a calendar month, then subject to the exceptions, conditions and notifications below, Customer shall be entitled to a credit equal to 7/30 of the monthly recurring fee for the Humidity Irregular Loaded Cabinet(s) (defined below) for the month following the month in which the Humidity Irregularities occurred; provided, however, that, notwithstanding the foregoing, for each of Customer’s Humidity Irregular Loaded Cabinet(s), in no event shall the maximum credit (i.e., the aggregate amount of the credits) to which Customer shall be entitled in any given calendar month exceed 7/30 of the monthly recurring fee for that Loaded Cabinet for the month in which the credit will be applied (which is the month following the month in which the Humidity Irregularities occurred for that Loaded Cabinet). For the avoidance of doubt, Customer shall not be entitled to a credit for any portion of the fees for the month in which the Humidity Irregularities occurred. For purposes of this Attachment B, Humidity Irregular Loaded Cabinets for any given calendar month are those Loaded Cabinets of Customer in the cage in which the Humidity Irregularities occurred during such calendar month. Cross-Connects If the path, connectors, or other passive physical media that Equinix uses fails for Cross-Connects due to circumstances caused solely by Equinix (“Media Failure”), then subject to the exceptions, conditions and notifications below, Customer will be entitled to a credit equal to the recurring fees for that Cross-Connect for the month following the month in which such Media Failure occurs; provided, however, that (i) Customer shall allow Equinix to test all Cross-Connects for which Customer reports Media Failure; (ii) unavailability of a Cross-Connect during such testing shall not be considered Media Failure hereunder; and (iii) for each Cross-Connect, in no event shall the maximum credit (i.e., the aggregate amount of the credits) to which Customer shall be entitled in any given calendar month exceed the monthly recurring fee for that Cross-Connect for the month in which the credit(s) will be applied (which is the month following the month in which the Media Failure(s) occurred for that Cross-Connect). For the avoidance of doubt, Customer shall not be enti...
Humidity. 1. Office Areas & Support Areas a. Summer 55% RH +/-15%
AutoNDA by SimpleDocs
Humidity. SLA For purpose of the Humidity SLA, the duration of a Service Outage shall be deemed to commence upon the opening of a Verifiable Trouble Ticket by LightEdge Technical Support, in response to the Customer request, and ends when the Service Outage ends. Trouble tickets, where the Service Outage cannot be verified with LightEdge's standard diagnostic procedures, do not count towards the Availability SLA. SLA Remedy 35-60% relative humidity Each 6 hours service is outside of SLA qualifies the Customer for a credit of 5% of MRC up to a maximum of 50% of MRR for affected service.
Humidity. 3.1.1.1.3.1 Best effort will be taken to maintain the humidity between fifteen percent (15%) and eighty percent (80%) at all times within colocation spaces.
Humidity. [*] [*] Note: The mw module must [*]