PG&E Drafting Note Sample Clauses

PG&E Drafting Note. PG&E to update for Project technologies other than energy storage Such log will include, but not be limited to, information on charging, discharging, availability, maintenance performed, outages, electrical characteristics of the energy storage systems] and similar information relating to the availability, testing and operation of the Project. Seller shall provide this information electronically to Buyer within thirty (30) days of Xxxxx’s written request. At the request of Buyer, the CPUC, or the staff of the CPUC, Seller shall provide all records demonstrating that the Project is operated and maintained in accordance with Prudent Electrical Practices and applicable Laws, including CPUC General Order 167.
AutoNDA by SimpleDocs
PG&E Drafting Note only applicable to energy storage Projects Seller shall have provided to Buyer an attestation, in the form attached hereto as Appendix XII, that Seller is following all of the rules set forth in the MUA Decision.]
PG&E Drafting Note only applicable to energy storage Projects finds that procurement under this Agreement counts as proposed by Buyer toward the energy storage target established by the Energy Storage Decision.]
PG&E Drafting Note only applicable to energy storage Projects During the Delivery Term, Seller shall be responsible for procuring and delivering all of the Charging Energy to the Project and paying all of the associated costs of such Charging Energy.]
PG&E Drafting Note only applicable to energy storage Projects] This attestation is delivered by _______(“Seller”) to Pacific Gas and Electric Company (“Buyer”) in accordance with the terms of that certain Long Term Resource Adequacy Agreement dated _______ (“Agreement”) by and between Seller and Buyer. All capitalized terms used in this attestation but not otherwise defined herein shall have the respective meanings assigned to such terms in the Agreement. Seller hereby certifies and represents to Buyer, as of the date set forth below, that with regard to the Project, Seller is following all the rules set forth in Appendix A of the MUA Decision. EXECUTED by SELLER this ________ day of _____________, 20__. Signature: Name: Title: END OF AGREEMENT [1]
PG&E Drafting Note. PG&E to remove for projects that can provide an interconnection study with estimates of the total cost of reimbursable Electric System Upgrades: (b)
PG&E Drafting Note only applicable to energy storage Projects “MUA Decision” means CPUC Decision 00-00-000 on Multiple-Use Application Issues, issued January 17, 2018, regarding the multiple-use applications of energy storage facilities.]
AutoNDA by SimpleDocs
PG&E Drafting Note only applicable to energy storage Projects] This attestation is delivered by _______(“Seller”) to Pacific Gas and Electric Company (“Buyer”) in accordance with the terms of that certain Behind the Retail Meter Resource Adequacy Agreement dated _______ (“Agreement”) by and between Seller and Buyer. All capitalized terms used in this attestation but not otherwise defined herein shall have the respective meanings assigned to such terms in the Agreement. Seller hereby certifies and represents to Buyer, as of the date set forth below, that with regard to the Project, Seller is following all the rules set forth in Appendix A of the MUA Decision EXECUTED by SELLER this ________ day of _____________, 20__. Signature: Name: Title: APPENDIX XIII LIST OF SUBSTATIONS [Seller to insert based on Offer] APPENDIX XIV EXAMPLE OF ENERGY SETTLEMENT CALCULATION This Appendix illustrates how the Energy Settlement would be calculated for one day. As the Energy Settlement calculation is computed on a monthly basis, this calculation would be repeated for every day of the month using that day’s Day-Ahead Prices. The following assumptions were used for this Energy Settlement example: Day: July 1 Variable O&M: $15.00/MWh duration of the Project: 4 hours
PG&E Drafting Note only applicable to energy storage Projects] This attestation is delivered by _______(“Seller”) to Pacific Gas and Electric Company (“Buyer”) in accordance with the terms of that certain Long Term Resource Adequacy Agreement with Energy Settlement dated _______ (“Agreement”) by and between Seller and Buyer. All capitalized terms used in this attestation but not otherwise defined herein shall have the respective meanings assigned to such terms in the Agreement. Seller hereby certifies and represents to Buyer, as of the date set forth below, that with regard to the Project, Seller is following all the rules set forth in Appendix A of the MUA Decision. EXECUTED by SELLER this ________ day of _____________, 20__. Signature: Name: Title: APPENDIX XIII EXAMPLE OF ENERGY SETTLEMENT CALCULATION This Appendix illustrates how the Energy Settlement would be calculated for one day. As the Energy Settlement calculation is computed on a monthly basis, this calculation would be repeated for every day of the month using that day’s Day-Ahead Price. The following assumptions are used for this Energy Settlement example: Day: July 1 round-trip efficiency of the Project in given contract year: 75% Variable O&M: $10.00/MWh duration of the Project: 4 hours Table 1: Day-Ahead LMP Prices for July 1 Day-Ahead Price ($/MWh) $21 $21 $22 $23 $25 $28 $32 $26 $15 $18 $18 $12 Day-Ahead Price ($/MWh) $12 $12 $16 $20 $18 $22 $31 $47 $41 $35 $32 $28 Largest 4 Day-Ahead Prices on July 1, ranked highest to lowest: $47.00/MWh $41.00/MWh $35.00/MWh $32.00/MWh Note: 4 hours is based on duration of the Project Smallest 6 Day-Ahead Prices on July 1, ranked lowest to highest: $12.00/MWh $12.00/MWh $12.00/MWh $15.00/MWh $16.00/MWh $18.00/MWh Note: 6 hours is based on duration of the Project (4 hours) plus 2 hours to account for round-trip efficiency in a given contract year Sample Calculation for July 1: Equation: ESd = ∑ max [0, (large (DAPi) – {Wt1i × small (DAPi) + Wt2i × small (DAPi+1) + Wt3i × small (DAPi+2)} – VOM)] Where: ESd = Energy Settlement for day d; ∑ = the sum from i = 1 to z, where z is the number of hours equal to the duration of the Project, expressed in hours Large (DAPi) = the i-th largest value of DAP for all Settlement Periods in day d, expressed in $/MWh Small (DAPi) = the i-th smallest value of DAP for all Settlement Periods in day d, expressed in $/MWh Wt1i = min (i, max (i-1, i/E)) – min (i, max (i-1, (i-1)/E)) Wt2i = min (i+1, max (i, i/E)) – min (i+1, max (i, (i-1)/E)) Wt3...
PG&E Drafting Note. PG&E to update for Project technologies other than energy storage: energy storage] facilities during the relevant time period, or any of the practices, methods and acts which, in the exercise of reasonable judgment in light of the facts known at the time a decision is made, that could have been expected to accomplish a desired result at reasonable cost consistent with good business practices, reliability, safety and expedition. Prudent Electrical Practices are not intended to be limited to the optimum practices, methods, or acts to the exclusion of others, but rather to those practices, methods and acts generally accepted or approved by a significant portion of the electric power industry in the relevant region, during the relevant time period, as described in the immediately preceding sentence. Prudent Electrical Practices also includes taking reasonable steps to ensure that:
Time is Money Join Law Insider Premium to draft better contracts faster.