Equipment Room Sample Clauses

Equipment Room. The Owner shall provide the Equipment Room to the Licensee, for the sole and exclusive use of the Licensee, which Equipment Room shall be used by the Licensee for the provision of communications services to the Licensee’s customers in the Building.
AutoNDA by SimpleDocs
Equipment Room. Owner grants to Huntington the sole and exclusive right and license (the "Equipment Room License") to use, occupy and possess the areas of the Property diagramed on Exhibit "C" attached hereto and incorporated herein by this reference (referred to as the "Equipment Room", regardless of the number of rooms actually diagramed or whether or not the area is, in fact, enclosed). The Equipment Room is to be used for the purpose of installing, operating, servicing, repairing and removing the equipment and related fixtures and installations utilized in connection with the performance of Huntington's obligations under this Agreement (the "Equipment").
Equipment Room. Subject to the provisions of Section 3(b) of the Lease, Tenant may install Tenant's Work in the Premises in accordance with the terms of the Lease and in compliance with the following:
Equipment Room. 13.13.1 See typical equipment room layout (SHEET U).
Equipment Room. The Owner shall provide a portion of approximately Sixty (60) square feet of the Equipment Room to the Licensee, for the sole and exclusive use of the Licensee, which portion of the Equipment Room shall be used by the Licensee for the provision of communications services to the Licensee’s customers in the Building.
Equipment Room. The equipment room must be at least 3,5 m high, being the ducts of the existing or to-be-ordered air conditioning already deduced; - The minimum installation area for up to 10 systems must be 12 m2 (3x4), being each frame's measurement the following: 120mm width, 225 mm depth and 2200mm height and availability of: - Power plant with 10A switches and at least two (2) 110/220 VCA plugs for testing tools; - Ground point with a maximum of 5 ohms of ohmic resistance; - Conduits on the ground and conveyors for running the equipment interconnection cables; - In case it is necessary, a duct or sub-duct net must be either allocated or built in the CONTRATING PARTY'S facilities, in accordance with the actual technical rules, for the installation of the optical fiber cable.
Equipment Room o Minimum height is not mandatory, since the equipment will be installed at 1.40m off the ground (in case a rack is used). o The minimum installation area for at least 16 systems of 2 Mbps is equivalent to 1,5m x 1,00m, being that 1,00m corresponds to the free space in wall for the allocation of the optical modem and of the BEO/DIO (Frame of Optical Alteration/ Optical Intermediate Distributor). o Power plant with 10A switches and at least two (2) 110/220 VCA plugs for testing tools; o Ground point with at least 5 ohms of ohmic resistance.
AutoNDA by SimpleDocs
Equipment Room. Licensee shall have, on an exclusive basis, the right to occupy the space shown on Exhibit (the "Equipment Room") for any of the foregoing purposes, and to install In the Equipment Room, in addition to Telecommunications Facilities, equipment belonging to Licensee's private customers and/or Service Providers. 3.
Equipment Room. Operation of the Ph Neutralization system and other existing Equipment Room Lab Systems (as defined in the Fourth Amendment) located therein and building systems serving the Former Addgene Space and for no other purpose.
Equipment Room. The Licensor shall provide a portion or area or the entire area within the Equipment Room (the “Premises”) to the Licensee, for the sole and exclusive use of the Licensee, which shall be used by the Licensee for the provision of communications services to the Licensee’s customers in the Building.