BILL NO Sample Clauses

BILL NO. 08 STRUCTURAL STEEL Pre-galvanised (Z450) structural steelwork (Grade 350W) 100 x 50 x 20 x 2mm Cold formed lipped channel including bolting to brickwork at 910mm centres. A1 : 2 C1 : 0 D1 : 3 G1 : 6 H1 : 0 Quantity m 11 Rate Carried Forward to Summary of Section No. 2 R BUILDING WORKS Bill No. 8 STRUCTURAL STEEL Amount Item No SECTION No. 2
AutoNDA by SimpleDocs
BILL NO. 09 METALWORK Hot dipped galvanised mild steel gates Quantity Rate 1 Single gate, size 900mm wide x 2050mm high, the leaf formed of 25 x 25 x 2mm wall thickness mild steel pipe framing all round and two horizontal intermediate rails with mitred and welded angles, the gate filled in with 12mm diameter mild steel bars welded, at each end, vertically to perimeter and intermediate framing at not exceeding 109mm centres, the leaf fitted with a 150mm long padbolt, the leaf to receive hasp and staple formed of 40 x 6mm mild steel flat bar welded onto frames and including fitting with two 50 x 10mm flat bar tee brackets and 16mm round bar pin hinges, twice bolted to wall with and including M16 x 95mm galvanised coach screws. No 6 A1 : 2 C1 : 1 D1 : 2 G1 : 1 H1 : 0 Hot dipped galvanised mild steel mesh screen 2 Mesh screen, size 2230mm wide x 2100mm high, formed of 32 x 32 x 2mm wall thickness square hollow section framing all round and two horizontal rails with mitred and welded angles, the framing covered with 50 x 50 x 4mm weld mesh tack welded on, and including fitting with two 50 x 10mm flat bar tee brackets and 16mm round bar pin hinges, twice bolted to wall with and including M16 x 95mm galvanised coach screws. No 1 A1 : 0 C1 : 1 D1 : 0 G1 : 0 H1 : 0 Carried to Collection R BUILDING WORKS
BILL NO. 8 METALWORK SUPPLEMENTARY PREAMBLES For preambles see "Specifications of materials and methods to be used - PW 371" PRESSED STEEL DOOR FRAMES 1,2mm Single rebated frames suitable for half brick walls: 1 Frame for door 813 x 2032mm high No 1 1,6mm Double rebated frames suitable for one brickwalls: 2 Frame for door 813 x 2032mm high No 2 STEEL WINDOWS, DOORS, ETC 3 Window type NE1, 533 x 654mm high including burglar bars No 4 4 Window type NE 7,1022 x 654mm high including burglar bars No 2 WELDED SCREENS, GATES, ETC Steel gates and frames: 5 Purpose made square hallow section mild steel security gate, size 813 x 2032mm High No 2 Carried Forward to Summary of Section No. 2 Section No. 2 SMD1 BLOCK Bill No. 8 METALWORK MANKGA LERAGA CONSULTING R Item No SECTION 2 Quantity Rate BILL NO. 9 PLASTERING
BILL NO. 9 PLASTERING Quantity Split: Note that the total quantity per each item is split into the various buildings and appears below each description as follows: A1 - DWG 04 - Staff Ablutions (2M2F1D) A2 - DWG 06 - Grade R Ablution (3R1T) A3 - DWG 14 - Male Ablutions (6B) A4 - DWG 35 - Female Ablutions (6G) MODEL PREAMBLES The tenderer is referred to the "Model Preambles for Trades 2008" for supplementary and comprehensive expansion of descriptions, appropriate provision for which shall be deemed to have been included in all relevant rates SCREEDS 1:3 Cement and sand screeds steel trowelled on concrete: 1 30mm Thick on floors. m2 107 A1 : 31 A2 : 24 A3 : 22 A4 : 30 INTERNAL PLASTER Cement plaster on substructure brickwork (pit walls): 2 On walls. m2 268 A1 : 84 A2 : 67 A3 : 31 A4 : 86 Cement plaster on superstructure brickwork: 3 On walls. m2 430 A1 : 132 A2 : 93 A3 : 86 A4 : 119 Carried Forward to Summary of Section No. 2 Section 2 Bill No. 9 Plastering Item Quantity Rate Amount
BILL NO. 9 PLASTERING Quantity Split: Note that the total quantity per each item is split into the various buildings and appears below each description as follows: A1 - DWG 04 - Staff Ablutions (2M2F1D) A2 - DWG 10 - Male Ablution (8B) A3 - DWG 17 - Female Ablutions (8G) MODEL PREAMBLES The tenderer is referred to the "Model Preambles for Trades 2008" for supplementary and comprehensive expansion of descriptions, appropriate provision for which shall be deemed to have been included in all relevant rates SCREEDS 1:3 Cement and sand screeds steel trowelled on concrete: 1 30mm Thick on floors. m2 97 A1 : 31 A2 : 29 A3 : 37 INTERNAL PLASTER Cement plaster on substructure brickwork (pit walls): 2 On walls. m2 258 A1 : 84 A2 : 59 A3 : 115 Cement plaster on superstructure brickwork: 3 On walls. m2 386 A1 : 132 A2 : 111 A3 : 143 Carried Forward to Summary of Section No. 2 Section 2 Bill No. 9 Plastering Item Quantity Rate Amount
BILL NO. 9 PLASTERING SUPPLEMENTARY PREAMBLES For preambles see "Specifications of materials and methods to be used - PW 371" CEMENT SCREEDS TO CONCRETE Screeds to steel trowelled, on concrete: 1 30mm thick on floors m2 25 INTERNAL PLASTER Cement plaster on brickwork or blockwork: 2 On pits walls m2 37 FLOOR AND WALLS SEALERS Minimum two coats approved epoxy coat: 3 On screed m2 25 4 On internal textured plaster walls and floors in pit m2 45 Carried Forward to Summary of Section No. 4 Section No. 4 MD3 Bill No. 9 PLASTERING BVI CONSULTING ENGINEERS R R Amount 60 209.00 5 000.00 Item Quantity Rate
BILL NO. 7 IRONMONGERY SUPPLEMENTARY PREAMBLES For preambles see "Specifications of materials and methods to be used - PW 371" CATCHES, CABIN, HOOKS, ETC Approved: 1 150mm Cabin hook and eye including 70 x 70 x 20mm chamfered hardwood block twice oiled and plugged No 2 LOCKS Approved: 2 Three lever mortice lockset No 2 3 Indicator lockset No 6 DOORSTOPS Approved: 4 38mm Diameter rubber door stop plugged No 8 LETTERS, NAMEPLATES, ETC. "Union" or similar approved: 5 75 x 150mm Natural anodised aluminium plate with male or female symbol No 2 Carried Forward Section No. 4 MD6 Bill No. 7 IRONMONGERY BVI CONSULTING ENGINEERS R Brought Forward R
AutoNDA by SimpleDocs
BILL NO. 7 CEILINGS, PARTITIONS AND ACCESS FLOORING The tenderer is referred to the relevant Clauses in the Model Preambles for Trades and to the Supplementary Preambles which are incorporated at the front of these Bills of Quantities Quantity 475 11 204 63 Rate R Amount SUSPENDED CEILINGS 600 x 600 x 0.5mm "OWAtecta" flat lay-in metal ceiling tiles with perforation type L2516, including black Soundtex acoustic fleece infill material bonded to tiles with four tegular adges and OWA white powder coated finish laid on OWAconstruct S33 exposed demountable T24 tee suspension system, all installed to manufacturer's specifications. OWAconstruct shadowline W-trim plugged and screwed at 1200mm centres Ceilings suspended not exceeding 1,0 m below soffit of steel or timber roof structure. m2 Extra over ceiling for forming trapdoor 600 x 600mm hinged pressed metal with 38 x 50mm sawn softwood braced framing No "SM25" pre-painted cornices, nailed m 9,5 mm Gypsum plasterboard ceiling suspended by means of the "screw up" system to and including "Xxxx T37S" system suitably spaced and framed to prevent all deflection or sagging, all framed and screwed up, suspended or shot bolted to concrete or brickwork and using boards in long lengths and fixing to studs at 150 mm centres to maintain ceiling board firmly in position, apply Fibatape to all joints and scrimmed and skimmed with 3 - 6 mm "Rhinolite" to entire surface and sanded down to leave a perfectly flush and level ceiling Ceilings suspended not exceeding 1,0 m below concrete soffit m2 Carried Forward Section No. 2 BUILDING WORKS Bill No. 7 CEILINGS AND PARTITIONS 5 6 7 8 9 10 11 12 Brought Forward Shadowline cornice m BULKHEADS Vertical ceilings or bulkhead average 400mm high. m Vertical ceilings or bulkhead average 200mm high. m OFFICE PARTITIONS Gyproc 1 hour fire rated - GypWall SoundBloc Ultrasteel Stud Drywall, consisting of stud and track system with 63,5 x 35mm Xxxx Drywall UltraSTEEL™ studs at 600mm centres friction fitted into head track and floor track with 63mm Isover "Cavitybatt" insulation inserted into cavity of partitioning and clad on both sides with a double layer of 15mm thick Gyproc SoundBloc board fixed with 25mm and 42mm Gyproc RhinoBoard Sharp Point Screws at 220mm centres and resilient bars to one side with all external angles to have Drywall cornerbeads attached and all joints to be covered with RhinoTape and finished with two layers of RhinoGlide applied and lightly sanded down, leaving wall surface prep...
BILL NO. 07 IRONMONGERY IRONMONGERY TO TIMBER Hinges 1 100 x 75mm Heavy duty brass butt hinges. No 6 A1 : 0 C1 : 6 D1 : 0 G1 : 0 H1 : 0 Handles 2 100mm Chromium plated pull handle. A1 : 0 C1 : 3 D1 : 0 G1 : 0 No 3 H1 : 0 Ite No Rate IRONMONGERY TO METALWORK Locksets, etc. provided with two keys and to be masterkeyed 3 51mm brass padlock with stainless steel shackle. No 6 A1 : 2 C1 : 1 D1 : 2 G1 : 1 H1 : 0 IRONMONGERY FIXED TO CONCRETE, TILING, ETC. Push plates, kicking plates, indicator plates, etc. 4 152 x 152 x 3mm Thick anodised silver aluminium sex indicator plate. No 5 5 A1 : 2 C1 : 1 D1 : 1 G1 : 1 H1 : 0 152 x 152 x 3mm Thick anodised silver aluminium disabled indicator plate. No A1 : 0 C1 : 0 D1 : 0 G1 : 1 H1 : 0 Carried to Collection BUILDING WORKS Bill No. 7 IRONMONGERY 1 R Amount 3mm Thick x 32mm high clear perspex signs with white painted numerals or letters, countersunk tap screwed to steel door frame 1 Sign with "MALE STAFF" enscribed. No 1 A1 : 1 C1 : 0 D1 : 0 G1 : 0 H1 : 0 2 Sign with "FEMALE STAFF" enscribed. No 1 A1 : 1 C1 : 0 D1 : 0 G1 : 0 H1 : 0 Door stops 3 Black rubber door stop plugged to wall. No 19 A1 : 3 C1 : 3 D1 : 4 G1 : 9 H1 : 0 Sundries 4 50mm Plastic key tag. No 8 A1 : 2 C1 : 1 D1 : 2 G1 : 3 H1 : 0 Carried to Collection R BUILDING WORKS Bill No. 7 IRONMONGERY Section No. 2 BUILDING WORKS
BILL NO. 10 PLASTERING SCREEDS Untinted granolithic screeds, etc. mixed by volume 4 parts granite chips, 1 part sand and 2 parts cement 1 40mm Thick screed to floors and landings. m2 65 A1 : 11 C1 : 6 D1 : 23 G1 : 25 H1 : 0 2 25mm Thick screed to falls m2 19 A1 : 3 C1 : 3 D1 : 4 G1 : 9 H1 : 0 Skirtings 3 75mm High coved skirting. A1 : 18 C1 : 16 D1 : 38 G1 : 53 m 125 H1 : 0 Ite No Rate PLASTER One coat internal 1:4 cement plaster on : 4 Brick walls in pit. m2 271 A1 : 39 C1 : 32 D1 : 57 G1 : 143 H1 : 0 5 Brick walls (ICP) A1 : 76 C1 : 48 D1 : 95 G1 : 97 m2 316 H1 : 0 Carried Forward to Summary of Section No. 2 BUILDING WORKS Bill No. 10 PLASTERING R Amount Item No SECTION No. 2 BILL No. 11 PLUMBING AND DRAINAGE (PROVISIONAL) Roof gutters, rainwater pipes, etc. uPVC gutter including gutter brackets Quantity Rate 1 125mm Half round xxxxx gutters on gutter brackets at 1000mm centres maximum fixed to fascias. A1 : 4 C1 : 3 D1 : 8 G1 : 10 H1 : 0 2 Extra over uPVC gutter for forming discharge outlet to suit 100 x 75mm downpipe. A1 : 1 C1 : 1 D1 : 1 G1 : 1 H1 : 0 3 Extra over gutter for stopped end. A1 : 2 C1 : 2 D1 : 2 G1 : 2 H1 : 0