Air Compressor Sample Clauses

The 'Air Compressor' clause defines the requirements and specifications for any air compressor equipment to be provided or used under the contract. It typically outlines the necessary performance standards, capacity, and safety features that the air compressor must meet, and may specify maintenance responsibilities or compliance with relevant regulations. By clearly setting these expectations, the clause ensures that the equipment supplied is suitable for its intended use and helps prevent disputes over quality or operational issues.
POPULAR SAMPLE Copied 1 times
Air Compressor remove this. FMC sized the air compressor.
Air Compressor. Air compressor shall be a Wabco brand, minimum of 18.7 cubic feet per minute capacity. Air brake system shall be the quick build up type. The air compressor discharge line shall be stainless steel braid reinforced Teflon hose.
Air Compressor. The air compressor system will demonstrate the ability to generate the designed flow rate of 1,000 cfm compressed air, and a maximum dew point of-40F while generating less than 80 db of noise outside the compressor shed.
Air Compressor. Air Compressor: • Expand air compressor & air dryer capacity, one new 1,000 cfm air compressor with one receiver and one regenerative dryer sized for the application • Air compressor/dryer system will not exceed 80 db noise limits outside compressor shed. • Dryer will provide -40 F dew point air with system operating at full air flow, • One compressor shed
Air Compressor. Quantity (1) Manufacturer Castair Performance 4.6 cfm @ 100 psi Processor (PLC) ▇▇▇▇▇‐▇▇▇▇▇▇▇ CompactLogix, data logging onto flash card and ethernet communication. Operator Interface (HMI) ▇▇▇▇▇‐▇▇▇▇▇▇▇ Panel View 1000 Color Touchscreen. Enclosures ▇▇▇▇▇▇▇ Concept, Painted Steel, NEMA 4/12 Conduit Liquid‐Tight Flexible Metal Conduit or PVC Rigid Conduit Location Main Control Panel mounted on RO Skid & wired to RO Instruments and Valves. RO Skid Inlet Schedule 80 PVC RO Skid High Pressure Schedule 10 304 Stainless Steel RO Skid Permeate Schedule 80 PVC RO Skid Concentrate Schedule 80 PVC Interconnecting Piping Interconnecting plumbing between RO skid and feed, CIP and flush tanks shall be provided by others. Pump Quantity 3 (antiscalant, acid and sodium bisulfite) Manufacturer Pulsafeeder Type Peristaltic Other In‐line static mixer on RO feed, calibration columns and check valves on chemical lines. Tank Quantity (3) located on RO skid Manufacturer Norwesco Vessel Construction HDPE Capacity 10 gallons, flat bottom Dimensions 13” dia. x 20” hgt. Quantity (3) located on RO skid Manufacturer Penguin Type Drum mixer Tank Quantity (1) shipped loose Manufacturer Norwesco Vessel Construction HDPE Capacity 105 gallons, flat bottom Dimensions 23” dia. x 63” hgt. Pump Quantity (1) located on RO skid Manufacturer Grundfos CMG3‐5 Type Multistage centrifugal Pump Construction Stainless steel Motor HP 2 HP Performance 20 gpm @ 58 psi
Air Compressor. Asphalt Spreader; Combination - Small Equipment Operator; Generators; Heaters, Mechanical; Hoists, Inside Elevators - (Rheostat Manual Controlled); Hydraulic Power Units (Pile Driving, Extracting, or Drilling - with a seat); Lowboys; Pumps, Over 3" (1 to 3 not to exceed total of 300 ft.); Pumps, Well Points; Welding Machines (2 through 5); Winches, 4 Small Electric Drill Winches; Bobcat (up to and including 3/4 cu. yd.). Class 4. Elevator push button with automatic doors; Hoists, Inside; Oilers; Brick Forklift. Class 5. Assistant Craft ▇▇▇▇▇▇▇
Air Compressor. 1) Inspect for proper operation and pressures 2) Check oil level 3) Inspect and drain any accumulated water from water separation filter, replace filter element as necessary to maintain proper operation 4) Inspect all electrical connections for correct amperages and voltages 5) Tighten all electrical connections and ensure that they are free from corrosion 6) Inspect main pneumatic lines for moisture build up.
Air Compressor. TENANT MAINTENANCE Tenant shall, at its sole cost and expense, keep and maintain the Premises (including appurtenances) and every part thereof in a high standard of maintenance and repair, and in good and sanitary condition. Tenant's maintenance and repair responsibilities herein referred to include, but are not limited to, janitorization, plumbing systems within the non-common areas of the Premises (such as water and drain lines, sinks), electrical systems within the non-common areas of the Premises (such as outlets, lighting fixtures, lamps, bulbs, tubes, ballasts, heating and airconditioning controls within the non-common areas of the Premises (such as mixing boxes, thermostats, time clocks, supply and return grills), all interior improvements within the premises including but not limited to: wall coverings, window coverings, acoustical ceilings, vinyl tile, carpeting, partitioning, doors (both interior and exterior, including closing mechanisms, latches, locks), and all other interior improvements of any nature whatsoever. Tenant agrees to provide carpet shie▇▇▇ ▇▇▇er all rolling chairs or to otherwise be responsible for wear and tear of the carpet caused by such rolling chairs if such wear and tear exceeds that caused by normal foot traffic in surrounding areas. Areas of excessive wear shall be replaced at Tenant's sole expense upon Lease termination.
Air Compressor. Type: LS12-50HH, Make: America sullair Amount: 2 Motor: 50HP Location: Air source purified device Air Heater Air cooler Characteristics 230 STF at 125 psi
Air Compressor. The engine-driven air compressor shall be sized to charge the air system from 40 PSI to the governor cutoff pressure in less than 3 minutes while not exceeding the fast idle speed setting of the engine. The air compressor shall be heavy-duty design and adequately sized to ensure constant air supply on demand without over cycling of the compressor. The air compressor shall not pass oil into the air system or cause carbon to restrict the air lines under any condition. The air compressor shall be protected from negative inlet conditions that may cause oil to be drawn into the air system.