Unbundled Sub-Loop Sample Clauses

Unbundled Sub-Loop. Feeder (USLF) provides connectivity between BellSouth's central office and its cross-box (or other access point) that serves an end user location.
AutoNDA by SimpleDocs
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscriber’s building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscribers’ building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises. In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel that will be installed for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25 pair increments for ITC^DeltaCom’s use on this cross-connect panel. ITC^DeltaCom will be responsible for connecting its facilities to the 25 pair cross- connect block(s).
Unbundled Sub-Loop. Feeder Loop, 4 Wire Ground-Start, Voice Grade - Zone 2 UEA USBFD 35.92 226.36 144.28 19.99 19.99 19.99 19.99
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscribers’ building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.2.8.5In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel that will be installed for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25 pair increments for NATIONSLINK COMMUNICATIONS’ use on this cross-connect panel NATIONSLINK COMMUNICATIONS will be responsible for connecting its facilities to the 25 pair cross-connect block(s).
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscribers’ building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.2.8.5In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel that will be installed for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25 pair increments for Momentum Business Solutions’ use on this cross-connect panel Momentum Business Solutions will be responsible for connecting its facilities to the 25 pair cross-connect block(s).
AutoNDA by SimpleDocs
Unbundled Sub-Loop. Feeder Loop, Per 2 Wire Ground-Start, Voice Grade - Zone 3 UEA USBFA 21.04 122.52 46.61 149.46 59.37 19.99 19.99 19.99 19.99 Order Coordination for Specified Conversion Time, per LSR UEA OCOSL 45.34 Unbundlde Sub-Loop Feeder Loop, 2 Wire Loop-Start, Voice Grade - Zone 1 UEA USBFB 11.43 122.52 46.61 149.46 59.37 19.99 19.99 19.99 19.99
Unbundled Sub-Loop. Modification Unbundled Sub-Loop Modification - 2-W Copper Dist Load Coil/Equip Removal per 2-W PR UEF ULM2X $355.71 $12.26 $18.94 $8.42 Unbundled Sub-loop Modification - 4-W Copper Dist Load Coil/Equip Removal per 4-W PR UEF ULM4X $355.71 $12.26 $18.94 $8.42 Unbundled Sub-loop Modification - 2-w/4-w Copper Dist Bridged Tap Removal, perPR unloaded UEF ULM4T $560.55 $14.30 $18.94 $8.42 Unbundled Network Terminating Wire (UNTW) Unbundled Network Terminating Wire (UNTW) per Pair UENTW UENPP $1.37 $2.48 $2.48 $1.74 $1.74 $18.94 $8.42 Network Interface Device (NID) Network Interface Device (NID) - 1-2 lines UENTW UND12 $86.46 $56.75 $18.94 $8.42 Network Interface Device (NID) - 1-6 lines UENTW UND16 $127.93 $98.21 $18.94 $8.42 Network Interface Device Cross Connect - 2 W UENTW UNDC2 $11.73 $11.73 $18.94 $8.42 Network Interface Device Cross Connect - 4W UENTW UNDC4 $11.73 $11.73 $18.94 $8.42 UNBUNDLED LOOP CONCENTRATION CATEGORY NOTES UNBUNDLED NETWORK ELEMENT Interim Zone BCS USOC RATES OSS RATES Charge - Charge - Svc Order Svc Order Incremental Incremental Manual Svc Manual Svc Submitted Submitted Charge - Manual Charge - Manual Order vs. Order vs. Elec Manually per Svc Order vs. Svc Order vs. Electronic-Disc Electronic-Disc per LSR LSR Electronic-1st Electronic-Add'l 1st Add'l Nonrecurring Nonrecurring Disconnect Recurring First Add'l First Add'l SOMEC XXXXX XXXXX XXXXX XXXXX XXXXX Unbundled Loop Concentration - System A (TR008 ULC UCT8A $441.42 $650.81 $650.81 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - System B (TR008 ULC UCT8B $52.97 $271.17 $271.17 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - System A (TR303 ULC UCT3A $478.93 $650.81 $650.81 Unbundled Loop Concentration - System B (TR303 ULC UCT3B $89.26 $271.17 $271.17 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - DS1 Loop Interface Car ULC UCTCO $5.04 $126.57 $92.14 $33.57 $9.40 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - ISDN Loop Interface (Brite Card UDN ULCC1 $8.00 $21.07 $20.96 $10.78 $10.71 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - UDC Loop Interface (Brite Card UDC ULCCU $8.00 $21.07 $20.96 $10.78 $10.71 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - -2 Wire Voice-Loop Start or Ground Start LoopInterface (POTS Card) UEA ULCC2 $2.00 $21.07 $20.96 $10.78 $10.71 $18.94 $8.42 Unbundled Loop Concentration - 2 Wire Voice - Reverse Battery Loop Interface(SPOTS Card) UEA ULCCR $11.89 $21.07 $20.96 $10.78 $10.71 $18.94 $8...
Unbundled Sub-Loop. Concentration System (USLC)
Time is Money Join Law Insider Premium to draft better contracts faster.