Wood and/or Concrete Soffits Sample Clauses

Wood and/or Concrete Soffits. A) WOOD SOFFIT: Remove and discard all damaged, deteriorated soffit material and soffit screens and haul away from property (per Sections 2.19 - 2.20). Repair damaged and deteriorated rafters’ ends and soffit framing as necessary. Provide and install new soffit wood along with new aluminum framed soffit vents at approximate 32” intervals around the perimeter. All soffit shall be secured with non-corrosive nails. Soffit, soffit vent and screens shall be with matching size and materials. Remove all attachments to soffit and reattach as required after soffit replacement. All intersections of new soffit and existing structure are to be caulked and sealed. Apply one coat of low VOC primer /sealer and two coats of low VOC exterior paint at soffits and the complete perimeter of the house.
AutoNDA by SimpleDocs

Related to Wood and/or Concrete Soffits

  • Trunk Group Connections and Ordering 5.2.1 For both One-Way and Two-Way Interconnection Trunks, if Onvoy wishes to use a technically feasible interface other than a DS1 or a DS3 facility at the POI, the Parties shall negotiate reasonable terms and conditions (including, without limitation, rates and implementation timeframes) for such arrangement; and, if the Parties cannot agree to such terms and conditions (including, without limitation, rates and implementation timeframes), either Party may utilize the Agreement’s dispute resolution procedures.

  • Tropical Hardwood and Virgin Redwood Ban Pursuant to San Francisco Environment Code Section 804(b), the City urges Contractor not to import, purchase, obtain, or use for any purpose, any tropical hardwood, tropical hardwood wood product, virgin redwood or virgin redwood wood product.

  • Occupational First Aid Requirements and Courses (a) The Union and the Employer agree that First Aid Regulations made pursuant to the Workers' Compensation Act shall be fully complied with.

  • FLOODPLAIN MANAGEMENT AND WETLAND PROTECTION Executive Order 11988, Floodplain Management, May 24, 1977 (42 FR 26951), 3 C.F.R., 1977 Comp., p. 117, as interpreted in HUD regulations at 24 C.F.R. Part 55, particularly Section 2(a) of the Order (For an explanation of the relationship between the decision- making process in 24 C.F.R. Part 55 and this part, see § 55.10.); and Executive Order 11990, Protection of Wetlands, May 24, 1977 (42 FR 26961), 3 C.F.R., 1977 Comp., p. 121 particularly Sections 2 and 5. COASTAL ZONE MANAGEMENT The Coastal Zone Management Act of 1972 (16 U.S.C. § 1451, et seq.), as amended, particularly sections 307(c) and (d) (16 U.S.C. § 1456(c) and (d)).

  • Prohibition Against Selecting and Installing Products Containing Hazardous Materials The Contractor shall not select, install or otherwise incorporate any products or materials containing Hazardous Materials within the boundaries of the Site. Should the Contractor or any Subcontractors have knowledge that, or believe that, an item, component, material, substance, or accessory within a product or assembly selected by the Contractor or any Subcontractor may contain Hazardous Materials it is the Contractor’s responsibility to secure a written certification from the manufacturer of any suspected material which identifies the specific Hazardous Material(s) contained, together with the Material Safety Data Sheets (MSDS) for such materials which shall be submitted to the Owner and Design Professional.

  • Firearm and Ammunition Industries (Tex 6 Gov. Code 2274) If (a) Vendor is not a sole proprietorship; (b) Vendor has at least ten (10) full-time employees; and (c) this Agreement or any Supplemental Agreement with certain public entities have a value of at least $100,000 that is paid wholly or partly from public funds; (d) the Agreement is not excepted under Tex. Gov. Code 2274 and (e) the purchasing public entity has determined that Vendor is not a sole-source provider or the purchasing public entity has not received any bids from a company that is able to provide this written verification, the following certification shall apply; otherwise, this certification is not required. Vendor certifies that Vendor, or association, corporation, partnership, joint venture, limited partnership, limited liability partnership, or limited liability company, including a wholly owned subsidiary, majority-owned subsidiary parent company, or affiliate of these entities or associations, that exists to make a profit, does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association and will not discriminate during the term of this contract against a firearm entity or firearm trade association.

  • Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)

  • Special Rules Regarding Related Entities and Branches That Are Nonparticipating Financial Institutions If a Finnish Financial Institution, that otherwise meets the requirements described in paragraph 1 of this Article or is described in paragraph 3 or 4 of this Article, has a Related Entity or branch that operates in a jurisdiction that prevents such Related Entity or branch from fulfilling the requirements of a participating FFI or deemed-compliant FFI for purposes of section 1471 of the U.S. Internal Revenue Code or has a Related Entity or branch that is treated as a Nonparticipating Financial Institution solely due to the expiration of the transitional rule for limited FFIs and limited branches under relevant U.S. Treasury Regulations, such Finnish Financial Institution shall continue to be in compliance with the terms of this Agreement and shall continue to be treated as a deemed- compliant FFI or exempt beneficial owner, as appropriate, for purposes of section 1471 of the U.S. Internal Revenue Code, provided that:

  • DAMAGE TO COUNTY FACILITIES, BUILDINGS OR GROUNDS 8.16.1 The Contractor shall repair, or cause to be repaired, at its own cost, any and all damage to County facilities, buildings, or grounds caused by the Contractor or employees or agents of the Contractor. Such repairs shall be made immediately after the Contractor has become aware of such damage, but in no event later than thirty (30) days after the occurrence.

  • DS3 Loop DS3 Loop is a two-point digital transmission path which provides for simultaneous two-way transmission of serial, bipolar, return-to-zero isochronous digital electrical signals at a transmission rate of 44.736 megabits per second (Mbps) that is dedicated to the use of the ordering CLEC in its provisioning of local exchange and associated exchange access services. It may provide transport for twenty-eight (28) DS1 channels, each of which provides the digital equivalent of twenty-four (24) analog voice grade channels. The interface to unbundled dedicated DS3 transport is a metallic-based electrical interface.

Time is Money Join Law Insider Premium to draft better contracts faster.