Washers and Dryers Sample Clauses

Washers and Dryers. The City shall provide, install, and maintain one commercial washer and one commercial dryer in each Fire Station that is renovated and each new station that is built. The City retains the discretion to determine which commercial washer/dryer models will be installed.
AutoNDA by SimpleDocs
Washers and Dryers. If your unit currently has a W/D with washer/ventless dryer hookup and the plumbing and electrical connections are within the accepted NYC code, then your washer/dryer is “grand fathered” and you can replace the machines when needed. However please note that no new washers and or dryers will be allowed to be installed. Understood, Acknowledged and Agreed: Understood, Acknowledged and Agreed; By:_ Shareholder Contractor Name: Shareholder (Please Print) Title: Date: 150 EAST TENANTS CORP. ALTERATION AGREEMENT RIDER VI
Washers and Dryers. TENANT has been provided a washer and dryer in the Dwelling Unit. TENANT is required to turn the water valves "ON" immediately prior to "OFF" immediately after EACH use. Do not start the wash and then leave the unit unattended. TENANT will be held liable for any damages in the event of non-compliance. TENANT is required to check TENANT's WATER HOSES once per month and to contact LANDLORD immediately if TENANT notices any signs of wear, leaks, or any other damage. TENANT may be held liable for unreported damages.
Washers and Dryers. Washers and dryers are not to be used in apartment.
Washers and Dryers. The Co-op shall furnish washers and dryers in adequate numbers to accommodate the needs of CTC Residents. It shall be the responsibility of the Co-op to ensure the satisfactory operation of the washers and dryers at all reasonable times, whether the equipment is owned by the Co-op or leased from a third party operator. The University shall have no interest in the proceeds derived from the use or rental of the washers and dryers.

Related to Washers and Dryers

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • HEATING, VENTILATING AND AIR CONDITIONING General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the weather conditions identified in Chapter 13, “Energy Conservation” of the 1996 BOCA Building Code and supplemented by the “Building Code Rules”. All HVAC equipment shall be commercial or light industrial grade. If new construction it shall be installed at grade or within mechanical rooms for easy access and maintenance. If existing construction, roof mounted equipment will be considered after all other options have been exhausted, including the elimination of noise and vibration transfer to the structural members. The HVAC systems shall be zoned, with units sized and placed as required by heating and cooling loads on the building. Zoning of systems is dependent on the size, shape and orientation of the building. The HVAC system shall be divided into a minimum of 4 exterior and 1 interior temperature control zones. Return air shall be taken from the area supplied or adjacent to the area in the same temperature control zone. The ventilation and exhaust system shall be sized to maintain a positive pressure throughout the building envelope to limit air and dust infiltration. No HVAC ductwork shall be installed under the floor slab or underground.

  • Furniture Sub-Sublandlord represents and warrants that all furniture and equipment listed and described in Schedule “B” attached hereto is within the Sub-Subleased Premises (such equipment and furniture is hereinafter collectively referred to as the “Existing Furniture”). The Sub-Sublandlord warrants that the Existing Furniture is free of any financial lien or hypothec and that there are no service contracts affecting the Existing Furniture. The parties acknowledge and agree that, upon the execution and delivery of this Sub-Sublease, without the requirement of any additional consideration, all rights, title and ownership in and to the Existing Furniture shall be conveyed to and vest in Sub-Subtenant and Sub-Subtenant shall be free to maintain and/or dispose the Existing Furniture as Sub-Subtenant so elects in its sole discretion but subject to the terms hereof. The foregoing conveyance with respect to the Existing Furniture shall be self-executing and no additional documentation shall be required in order to evidence the aforementioned assignment and conveyance of the Existing Furniture to Sub-Subtenant. Sub-Sublandlord makes no representation or warranty as to the condition, fitness or suitability of such Existing Furniture for Sub-Subtenant’s purposes. Sub-Subtenant may, as it deems appropriate or necessary, reconfigure the Existing Furniture to combine with any of Sub-Subtenant’s furniture and equipment. Sub-Sublandlord shall have no obligation for the maintenance, repair or replacement of any such Existing Furniture.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • Engines POSITION SERIAL NO. TOTAL HOURS TOTAL CYCLES HRS/CYCLES SINCE LAST SHOP VISIT Time Remaining to Next LIFE LIMITED PART REMOVAL PART NAME HOURS CYCLES MSN MSN

  • GLASS The Tenant shall maintain the glass part of the demised premises, promptly replacing any breakage and fully saving the Landlord harmless from any loss, cost or damage resulting from such breakage or the replacement thereof.

  • Heating and Air Conditioning Tenant shall not use any method of heating or air-conditioning, other than that supplied by Landlord, without Landlord’s prior written consent.

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

  • Machinery Business machines and mechanical equipment belonging to Tenant which cause noise and/or vibration that may be transmitted to the structure of the Building or to any other leased space to such a degree as to be objectionable to Landlord or to any tenants in the Complex shall be placed and maintained by the party possessing the machines or equipment, at such party’s expense, in settings of cork, rubber or spring type noise and/or vibration eliminators, and Tenant shall take such other measures as needed to eliminate vibration and/or noise. If the noise or vibrations cannot be eliminated, Tenant must remove such equipment within ten (10) days following written notice from Landlord.

Time is Money Join Law Insider Premium to draft better contracts faster.