Ventilating and Air Conditioning Sample Clauses

Ventilating and Air Conditioning. Tenant shall have use of Landlord's ventilating and air-conditioning units or system in the Premises. Tenant shall provide regular preventative maintenance and is responsible for all maintenance, repair and replacement of such units at Tenant's sole cost and expense. Furthermore, Section 11.1 (b) Replacement is omitted in its entirety from the Lease.
AutoNDA by SimpleDocs
Ventilating and Air Conditioning. Exhibit "H" specifies the obligations of Landlord and Tenant (other than those obligations set forth in Article 13) regarding the ventilating and air-conditioning equipment and system serving the Premises or the Shopping Center. Tenant covenants and agrees to pay to Landlord, as Additional Rental and in the same manner as Minimum Annual Rental is payable, all charges as the same may be adjusted from time to time, and as more particularly set forth in said Exhibit H. Landlord, in its sole discretion, shall have the right, from time to time, to alter the ventilating and air conditioning systems and equipment serving the Shopping Center, or any part thereof, and Tenant agrees to execute and deliver to Landlord such documentation as may be required to effect such alteration.
Ventilating and Air Conditioning. “HVAC”). Lessor shall install the facilities for heating, ventilating, and air conditioning (“HVAC Equipment”) serving the Premises. Any HVAC Equipment serving the Common Areas or serving the Premises and other areas in the Shopping Center, shall be maintained and repaired by lessor and the cost of such maintenance and repairs shall be deemed a part of Common Area Expenses. Any HVAC Equipment serving the Premises exclusively or installed by lessee in the Premises shall be maintained and repaired by lessee at lessee’s sole cost during the Lease Term. Except as otherwise provided in this Lease, lessor shall assign to lessee all of lessor’s warranties with respect to the HVAC Equipment serving the Premises exclusively, to the extent such warranties may be assigned. Lessee shall have complete responsibility for maintenance and upkeep of the HVAC Equipment serving the Premises exclusively or installed by lessee in the Premises and lessee shall engage (and keep engaged) throughout the Lease Term a reputable service contractor for such purposes. Such service contract shall service the HVAC system at least two [2] times per Calendar Year during the Lease Term to provide routine maintenance. Lessee shall furnish to lessor, within fifteen (15) days after receipt of lessor’s written request thereof a copy of lessee’s service contract for such HVAC Equipment.
Ventilating and Air Conditioning. Two unregulated subsidiaries, American Combustion Industries, Inc. (ACI) and Washington Gas Energy Systems (WGESystems), design and renovate mechanical HVAC systems for commercial and governmental customers under construction contracts. The company recognizes income for contract terms of one or more years in duration using the percentage-of-completion method. For all other contracts, these subsidiaries use the completed contract method.
Ventilating and Air Conditioning. A. General Work Letter – Landlord Build 399 Binney/Relay – Page 36 Relay Therapeutics Level 2 Lab and Xxxxxx 000 Xxxxxx Xxxxxx Xxxxxxxxx, XX December 05, 2017
Ventilating and Air Conditioning. Schedule F entitled "Tenant Heating, Ventilating and Air-Conditioning" specifies the obligations of Landlord and Tenant (other than those obligations set forth in Article X) regarding the heating, ventilating, and air-conditioning equipment and system serving the Premises or the Shopping Center Area and the energy required to operate the heating, ventilating and air-conditioning equipment serving the Premises. Tenant covenants and agrees to pay to Landlord, as Additional Rental and in the same manner as Annual Basic Rental is payable, all charges as the same may be adjusted from time to time, as more particularly set forth in said Schedule F. Landlord, in its sole discretion, shall have the right, from time to time, to alter the heating, ventilating and air-conditioning systems and equipment serving the Shopping Center, or any part thereof, and Tenant agrees to execute and deliver to Landlord such documentation as may be required to effect such alteration, provided, however, that Tenant shall not be required to bear any portion of the cost of such alteration or to incur any additional financial obligation as a result of such alteration. Tenant shall not at any time overburden or exceed the capacity of the heating, ventilating and air-conditioning systems and equipment serving the Premises. If Tenant desires any additional equipment or revision of the design of the existing equipment, or if Landlord deems it necessary, because of internal loading causing the temperature in the Premises to exceed the temperature in the Common Areas, to install any additional equipment or revise the design of the existing equipment, such additional equipment or revised design shall be subject to Landlord's prior approval of Tenant's plans and specifications therefor and shall be at Tenant's sole cost and expense. If such additional equipment or revised design is approved by Landlord and if Landlord provides such additional equipment or revised design, Tenant agrees to pay Landlord, on demand, the cost for providing such additional equipment or revised design.
Ventilating and Air Conditioning. Furnish, install and maintain throughout the Term a complete year-round heating, ventilating, and air conditioning system to provide interior conditions to 78 degrees F. dry bulb and 50% relative humidity when outside conditions are 93 degrees F. dry bulb and 75 degrees F. wet bulb, and 68 degrees F. inside when outside temperatures are 10 degrees F., provided that in any given room or area of Tenant’s demised premises, the occupancy does not exceed one person for each 150 square feet, and total electric load does not exceed 5 xxxxx per sq. ft. for all purposes, including lighting and power, exclusive of HVAC. The air conditioning system will include a reasonable amount of ductwork and shall provide not less than .13 cubic feet of fresh air per minute per square foot of rentable floor area.
AutoNDA by SimpleDocs
Ventilating and Air Conditioning. All air conditioning equipment required within the Premises including insulated and non-insulated duct work, zone terminal units, temperature controls, air diffusers, air grilles and other air distribution specialties connected to Landlord's central variable volume single duct conditioned air distribution system. Controls shall be electronic controls as specified by Landlord for power and control to both the zone terminal control system and the building fire alarm systems (see Exhibit "E"). If Tenant's ceiling covers over the existing or new zone system junction boxes, then hinged, swing open panels allowing free local access to these devices by Landlord's maintenance staff must be provided by Tenant. THE DESIGN FOR TENANT'S HVAC WORK SHALL BE PREPARED BY AN AIR CONDITIONING ENGINEER APPROVED BY LANDLORD. SUCH WORK SHALL BE AT TENANT'S COST AND SHALL BE UNDER A DIRECT CONTRACT BETWEEN TENANT AND SUCH ENGINEER. THE WORK PURSUANT TO SUCH CONTRACT SHALL INCLUDE PREPARATION OF ALL DRAWINGS AND ALL LOAD CALCULATIONS REQUIRED BY EXHIBIT "E." Tenant's work pursuant to this paragraph 1 and pursuant to paragraphs 9, 10, 11, 12 and 18, as applicable, shall comply with Xxxxxxxx's "Standard Mechanical Installation Practices" issued by Landlord's Engineering Department (the "Standards"). Tenant or its general contractor shall be responsible to obtain the latest version of the Standards from Landlord's Engineering Department prior to commencing design of Xxxxxx's work. In the event of any conflict between the Standards, on the one hand, and this Exhibit "C" or Exhibit "E," on the other hand, Landlord's determination shall control. 2.
Ventilating and Air Conditioning. 1. Heating, ventilation and air conditioning as required to provide reasonably comfortable temperatures for normal business day occupancy (except holidays), Monday through Friday, from 8:00 AM to 6:00 PM, and Saturday from 8:00 AM to 1:00 PM, if so requested by Tenant, by providing at least 24 hours notice. HVAC services beyond the aforesaid hours of operation can be made available to Tenant, if so requested by Tenant, by providing at least 24 hours prior written notice and at a cost of $50.00 per hour per unit.

Related to Ventilating and Air Conditioning

  • HEATING, VENTILATING AND AIR CONDITIONING General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the weather conditions identified in Chapter 13, “Energy Conservation” of the 1996 BOCA Building Code and supplemented by the “Building Code Rules”. All HVAC equipment shall be commercial or light industrial grade. If new construction it shall be installed at grade or within mechanical rooms for easy access and maintenance. If existing construction, roof mounted equipment will be considered after all other options have been exhausted, including the elimination of noise and vibration transfer to the structural members. The HVAC systems shall be zoned, with units sized and placed as required by heating and cooling loads on the building. Zoning of systems is dependent on the size, shape and orientation of the building. The HVAC system shall be divided into a minimum of 4 exterior and 1 interior temperature control zones. Return air shall be taken from the area supplied or adjacent to the area in the same temperature control zone. The ventilation and exhaust system shall be sized to maintain a positive pressure throughout the building envelope to limit air and dust infiltration. No HVAC ductwork shall be installed under the floor slab or underground.

  • Heating and Air Conditioning Tenant shall not use any method of heating or air-conditioning, other than that supplied by Landlord, without Landlord’s prior written consent.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • Air Conditioning If the Apartment has been provided with a ledge for split air conditioning system with suitable provision for keeping outdoor units of the AC system and also the route to take refrigerant piping, which the Allottee shall have to strictly follow while installing AC units

  • Heat and Air-Conditioning Landlord shall provide and maintain heat, ventilation and air-conditioning (“HVAC”) equipment sufficient to maintain the Premises at comfortable temperatures for general office use, subject to all federal, state and municipal regulations, during Normal Building Operating Hours (as defined in the Rules and Regulations) and subject to compliance by Tenant with the following and the provisions of Section 6.2.4. If Tenant shall require HVAC at times other than Normal Building Operating Hours, Landlord may furnish such service and Tenant shall pay therefor such charges as may from time to time be in effect. If the temperature otherwise maintained in any portion of the Premises by the HVAC system is affected as a result of (i) the type or quantity of any lights, machines or equipment used by Tenant in the Premises, (ii) the occupancy of any portion of the Premises by more than one person per two hundred (200) square feet of rentable area, (iii) an electrical load for lighting or power in excess of the limits specified in Section 6.2.4, or (iv) any partitioning or other improvements installed by Tenant, then at Tenant’s sole cost, Landlord may install any equipment, or modify any existing equipment Landlord deems necessary to restore the temperature balance. Tenant agrees to keep closed, when necessary, blinds or other window treatments which, because of the sun’s position, must be closed to provide for the efficient operation of the air conditioning system, and Tenant agrees to cooperate with Landlord and to abide by the reasonable regulations and requirements which Landlord may prescribe for the proper functioning and protection of the HVAC system. Landlord shall have no responsibility for providing any service from Separate HVAC Equipment, as defined in Section 6.1.3.

  • HEATING The Hirer shall ensure that no unauthorised heating appliances shall be used on the premises when open to the public without the consent of the management committee. Portable Liquefied Propane Gas (LPG) heating appliances shall not be used.

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Sprinkler System If there now is or shall be installed in the Building a "sprinkler system", and such system or any of its appliances shall be damaged or injured or not in proper working order by reason of any act or omission of Tenant, Tenant's agents, servants, employees, licensees or visitors, Tenant shall forthwith restore the same to good working condition at its own expense; and if the New York Board of Fire Underwriters or the New York Fire Insurance Rating Organization or any bureau, department or official of the state or city government, shall require or recommend that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of Tenant's business, or the location of the partitions, trade fixtures, or other contents of the Premises, Tenant shall, at Tenant's expense, promptly make and supply such changes, modifications, alterations, additional sprinkler heads or other equipment.

  • HVAC A. Heating, ventilating and air conditioning equipment will be provided with sufficient capacity to accommodate a maximum population density of one (1) person per one hundred fifty (150) square feet of useable floor area served, and a combined lighting and standard electrical load of 3.0 xxxxx per square foot of useable floor area. In the event Tenant introduces into the Premises personnel or equipment which overloads the system’s ability to adequately perform its proper functions, Landlord shall so notify Tenant in writing and supplementary system(s) may be required and installed by Landlord at Tenant’s expense, if within fifteen (15) days Tenant has not modified its use so as not to cause such overload. Operating criteria of the basic system shall not be less than the following:

  • Electrical Provide drawings for the following systems: