Transmission The Custodian and the Fund shall comply with SWIFT’s authentication procedures. The Custodian will act on FT Instructions received via SWIFT provided the instruction is authenticated by the SWIFT system. § Written Instructions. Instructions may be transmitted in an original writing that bears the manual signature of an Authorized Person(s).
Fax Transmission A facsimile, telecopy or other reproduction of this Amendment may be executed by one or more parties hereto, and an executed copy of this Amendment may be delivered by one or more parties hereto by facsimile or similar instantaneous electronic transmission device pursuant to which the signature of or on behalf of such party can be seen, and such execution and delivery shall be considered valid, binding and effective for all purposes. At the request of any party hereto, all parties hereto agree to execute an original of this Amendment as well as any facsimile, telecopy or other reproduction hereof.
Interconnection 2.1.10 Startup Testing and Commissioning
Computer Transmission The Custodian is able to accept transmissions sent from the Fund’s computer facilities to the Custodian’s computer facilities. If the Fund determines to use its proprietary transmission or other electronic transmission method, it must provide Custodian sufficient notice and information to allow testing or other confirmation that FT Instructions received via the Fund Designated Security Procedure can be processed in good time and order. The Custodian may require the Fund to execute additional documentation prior to the use of such transmission method.
Facsimile Transmission A FT Instruction transmitted to the Custodian by facsimile transmission must be transmitted by the Fund to a telephone number specified from time to time by the Custodian for such purposes. The Custodian will then follow one of the procedures below:
Speed The relative importance we attach is “high”.
TRANSMISSION OF SHARES 17.1 If a Member dies the survivor or survivors (where he was a joint holder) or his legal personal representatives (where he was a sole holder), shall be the only persons recognised by the Company as having any title to his Shares. The estate of a deceased Member is not thereby released from any liability in respect of any Share, for which he was a joint or sole holder.
Delivery by Electronic Transmission This Agreement and any signed agreement or instrument entered into in connection with this Agreement or contemplated hereby, and any amendments hereto or thereto, to the extent signed and delivered by means of an electronic transmission, including by a facsimile machine or via email, shall be treated in all manner and respects as an original agreement or instrument and shall be considered to have the same binding legal effect as if it were the original signed version thereof delivered in person. At the request of any party hereto or to any such agreement or instrument, each other party hereto or thereto shall re-execute original forms thereof and deliver them to all other parties. No party hereto or to any such agreement or instrument shall raise the use of electronic transmission by a facsimile machine or via email to deliver a signature or the fact that any signature or agreement or instrument was transmitted or communicated through such electronic transmission as a defense to the formation of a contract and each such party forever waives any such defense.
Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.
Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.