Thickness Measurements Sample Clauses

Thickness Measurements. The measurement of insulation thickness and over sheath thickness shall be made on samples taken not less than 150mm from the ends of factory length. These measurements shall be taken as required by the purchaser, or if not so required on random samples taken by the manufacturer.
AutoNDA by SimpleDocs
Thickness Measurements. Verification of the installed tube thickness shall be determined by measuring the thickness of the available samples using a calibrated measuring device. A minimum of four (4) readings shall be taken from each sample (minus the coating thickness provided by the bidder) and the mean value of all readings shall be used. The sample thickness shall be acceptable if it meets or exceeds 90% of the design minimum wall thickness specified. Penalties assessed to the contractor for failing to obtain 90% of the design thickness are described in Part I, subsection 4.5.
Thickness Measurements. The measurement of insulation thickness and over sheath thickness shall be made on samples taken not less than 150mm from the ends of factory length. These measurements shall be taken as required by the purchaser, or if not so required on random samples taken by the manufacturer. The tenderer shall fill the following schedules: SCHEDULE 1 Technical Particulars and Guarantees for items 1: Rated 400 V, (1x6mm2) No. Description Unit Particulars 1x6 mm2 1 Line voltage of 3-phase circuit kV 0.4 2 Number of cores 1 3 Class of cable 4 Conductor - Cross sectional area mm2 6 - Material Copper - Over all dimension mm - Thickness of insulation over conductors mm 5 Filler Material 6 Number of wires per core 7 Completed cables - Over all diameter mm - Weight per meters kg - Minimum drum length m 8 Insulation - Type of curing - Minimum radial thickness 9 Outer covering - Material - Minimum average thickness mm 10 Cable drum - Diameter m - Width m - Weight loaded kg 11 Maximum rated temperature °C 12 Maximum Dc Resistance per Meter of cable At 20 C µΩ 13 Maximum AC resistance of conductor per meter of cable at maximum conductor Temperature µΩ 14 Insulation resistance per Meter of cable - At 20 ᵒC MΩ - At maximum rated temperature MΩ 15 Equivalent star reactance per meter of three phase circuit at 50 HZ PF 16 Charging current per phase per 1000 Meter of conductor at normal voltage

Related to Thickness Measurements

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Measurements All production shall be accurately measured using standards established by the American Gas Association (AGA) and/or the American Petroleum Institute (API) and all measuring devices shall be tamper proof as nearly as possible. Oil royalties due within the terms of this lease shall be calculated on actual and accurate measurements within API standards unless a different means of measurement, subject to Lessor's approval, is provided.

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

  • Methods of Measurement The methods used to identify the educational strengths and needs of students are set forth in the approved Application.

  • PERFORMANCE MEASUREMENTS Upon a particular Commission’s issuance of an Order pertaining to Performance Measurements in a proceeding expressly applicable to all CLECs generally, BellSouth shall implement in that state such Performance Measurements as of the date specified by the Commission. Performance Measurements that have been Ordered in a particular state can currently be accessed via the internet at xxxx://xxxx.xxxxxxxxx.xxx. The following Service Quality Measurements (SQM) plan as it presently exists and as it may be modified in the future, is being included as the performance measurements currently in place for the state of Tennessee. At such time that the TRA issues a subsequent Order pertaining to Performance Measurements, such Performance Measurements shall supersede the SQM contained in the Agreement. BellSouth Service Quality Measurement Plan‌ (SQM) Tennessee Performance Metrics Measurement Descriptions Version 2.00 Issue Date: July 1, 2003 Introduction

  • ROAD DIMENSIONS Purchaser shall perform road work in accordance with the dimensions shown on the TYPICAL SECTION SHEET and the specifications within this road plan.

  • Interim Measures 6.1 The Parties acknowledge that the British Columbia Claims Task Force made the following recommendation concerning interim measures:

  • Provisional Measures Article 50

  • Measurements and Dimensions Before ordering material or doing work that is dependent upon coordination with building conditions, the Contractor shall verify all dimensions, elevations, grades, and pitch by taking measurements at the building and shall be responsible for the correctness of same. Any discrepancies between the drawings and/or specifications and the existing conditions shall be referred to the Design Professional for additional instructions before any work affected thereby is begun.

Time is Money Join Law Insider Premium to draft better contracts faster.