Non-Synchronous Generation The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the high-side of the generator substation at a power factor within the range of 0.95 leading to 0.95 lagging, unless the NYISO or the Transmission Owner in whose Transmission District the Small Generating Facility interconnects has established a different power factor range that applies to all similarly situated non-synchronous generators in the control area or Transmission District (as applicable) on a comparable basis, in accordance with Good Utility Practice. This power factor range standard shall be dynamic and can be met using, for example, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors, or a combination of the two. This requirement shall only apply to newly interconnecting non-synchronous generators that have not yet executed a Facilities Study Agreement as of September 21, 2016.
Synchronous Generation The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the Point of Interconnection at a power factor within the range of 0.95 leading to 0.95 lagging, unless the NYISO or the Transmission Owner in whose Transmission District the Small Generating Facility interconnects has established different requirements that apply to all similarly situated generators in the New York Control Area or Transmission District (as applicable) on a comparable basis, in accordance with Good Utility Practice.
Energy Resource Interconnection Service (ER Interconnection Service).
Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)
Network Resource Interconnection Service (check if selected)
Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.
Net Metering If you generate electricity from a renewable generating facility to offset your electricity consumption and/or use net metering at any time during the term of this Agreement, you must notify Starion.
Technical Standards Applicable to a Wind Generating Plant i. Low Voltage Ride-Through (LVRT) Capability A wind generating plant shall be able to remain online during voltage disturbances up to the time periods and associated voltage levels set forth in the standard below. The LVRT standard provides for a transition period standard and a post-transition period standard.
Transportation Services i) In the event that transportation services for a student served by CONTRACTOR pursuant to an Individual Services Agreement are to be provided by a party other than CONTRACTOR or the LEA or its transportation providers, such services shall be reflected in a separate agreement signed by the parties hereto, and provided to the LEA and SELPA Director by the CONTRACTOR. Except as provided below, CONTRACTOR shall compensate the transportation provider directly for such services, and shall charge the LEA for such services at the actual and reasonable rates billed by the transportation provider, plus a ten percent (.10) administrative fee, unless a “flat rate” is provided in the transportation contract. In the event that the transportation provider notifies the LEA or SELPA Director that CONTRACTOR is more than 90 days behind in payment for transportation services, LEA shall have the right, in its sole and exclusive discretion, but not the obligation, to make payment for such services directly to the transportation provider, and to deduct such payments from any sums owed to CONTRACTOR pursuant to this Master Contract and any Individual Services Agreement between the parties. In the event that the LEA makes direct payment of the transportation provider’s charges, it shall be entitled to withhold both the transportation charges themselves and such additional amount as shall be reasonably necessary to compensate the LEA for the staff and other costs incurred in making direct payment of those charges. The remedies provided to the LEA pursuant to this Paragraph shall not be exclusive. CONTRACTOR shall not include transportation through the use of services or equipment owned, leased or contracted through the LEA unless expressly provided in the Individual Services Agreement for the student transported.
Fueling delivering or dispensing fuel, defueling and refueling, or any other transfer of fuel on Airport property.