Time for Submission Except as specified below, any claim by Contractor for a change in the Contract Time or the Material Completion and Occupancy Date shall be made within fourteen days of the day on which the Contractor becomes aware of the event on which the claim is based or, if the Contract Documents specify a shorter or longer period with respect to such event, within the period specified by the Contract Documents.
Deadline for Submission of Bids 19.1 Bids must be received by the Purchaser at the address specified under ITB Clause 18.2 no later than the time and date specified in the Bid Data Sheet. 19.2 The Purchaser may, at its discretion, extend this deadline for the submission of bids by amending the bidding documents in accordance with ITB Clause 7, in which case all rights and obligations of the Purchaser and bidders previously subject to the deadline will thereafter be subject to the deadline as extended.
Time Limits for Submission of Claim Failure by Purchaser to submit a Claim within established time limits shall relinquish the United States from any and all obligations whatsoever arising under the contract or portions thereof. Purchaser shall file such Claim within the following time limits:
Mechanisms for Cooperation 1. Pursuant to Article 149 (Objectives), the Parties hereby establish a Committee on Cooperation comprising representatives of each Party. 2. The Parties will designate nationals contact points to facilitate communication on possible cooperation activities. The contact points will work with government agencies, business sector representatives and educational and research institutions for the operation of this Chapter. 3. The Parties shall use diplomatic channels to promote dialogue and cooperation consistent with this Agreement. 4. The Committee shall have the following functions: (a) to monitor and assess the progress in implementing of the cooperation projects agreed by the Parties; (b) to establish rules and procedures for the conduct of its work; (c) to make recommendations of the cooperation activities under this Chapter, in accordance with the strategic priorities of the Parties; and (d) to review through regular reporting from the Parties, the operation of this Chapter and the application and fulfillment of its objectives between the relevant institutions of the Parties.
Solicitations for Subcontracts Including Procurement of Materials and Equipment: In all solicitations either by competitive bidding or negotiation made by the Engineer for work to be performed under a subcontract, including procurement of materials or leases of equipment, each potential subcontractor or supplier shall be notified by the Engineer of the Engineer’s obligations under this contract and the Acts and Regulations relative to Nondiscrimination on the grounds of race, color, or national origin.
Requirements for Protection In compliance with NPCC requirements and Good Utility Practice, Developer shall provide, install, own, and maintain relays, circuit breakers and all other devices necessary to remove any fault contribution of the Large Generating Facility to any short circuit occurring on the New York State Transmission System not otherwise isolated by Connecting Transmission Owner’s equipment, such that the removal of the fault contribution shall be coordinated with the protective requirements of the New York State Transmission System. Such protective equipment shall include, without limitation, a disconnecting device or switch with load- interrupting capability located between the Large Generating Facility and the New York State Transmission System at a site selected upon mutual agreement (not to be unreasonably withheld, conditioned or delayed) of the Developer and Connecting Transmission Owner. Developer shall be responsible for protection of the Large Generating Facility and Developer’s other equipment from such conditions as negative sequence currents, over- or under-frequency, sudden load rejection, over- or under-voltage, and generator loss-of-field. Developer shall be solely responsible to disconnect the Large Generating Facility and Developer’s other equipment if conditions on the New York State Transmission System could adversely affect the Large Generating Facility.
Technical Requirements for SCPs/Databases 10.5.3.1 BellSouth shall provide physical access to SCPs through the SS7 network and protocols with TCAP as the application layer protocol.
GUIDELINES FOR REVIEWS We may provide you areas on the Site to leave reviews or ratings. When posting a review, you must comply with the following criteria:
REPORT SUBMISSION 1. Copies of reporting packages for audits conducted in accordance with 2 CFR Part 200, Subpart F-Audit Requirements, and required by PART I of this form shall be submitted, when required by 2 CFR 200.512, by or on behalf of the recipient directly to the Federal Audit Clearinghouse (FAC) as provided in 2 CFR 200.36 and 200.512
Additional Requirements for Sleeping Rooms The Contractor shall provide departing Attendees a secured area for storing belongings.