Precast Concrete Sample Clauses

Precast Concrete. (a) The units of measurement shall be:
AutoNDA by SimpleDocs
Precast Concrete. All precast concrete members to be used in the works, such as covers, lintels, xxxxx, slabs, stairs, etc.., shall be manufactured on site or obtained from approved manufacturer. In either case casting shall be done under the supervision of the Engineer, whose approval of the place and method of casting must be obtained before starting work. If casting is done on the site, the Contractor shall prepare a suitable area near the structure for which the precast parts are intended, and samples of the precast work shall be submitted to the Engineer for approval before proceeding with the manufacture on site. Casting of the precast parts shall be completed in due time so as not to delay the completion of the structures and everything connected therewith. Unless otherwise directed, precast elements shall be of concrete Grade C30P. All precast elements shall be true to dimensions and shapes as shown on the Drawings. Concrete surfaces shall be smooth and all corners square or chamfered, as shown on the Drawings or directed by the Engineer. Lifting lugs and similar metal parts, whether part of the reinforcement steel or not, shall be incorporated in the elements during manufacture. Precast elements shall not be transported or otherwise handled until the end of the curing period, which shall be at least 14 days. Any precast concrete element becoming defective during casting or placing or from any other cause, and rejected by the Engineer, shall be removed from the Site by the Contractor who shall cast new elements to replace the rejected ones, and all expenses in connection therewith shall be borne by the Contractor.
Precast Concrete. 2.17.1 Precast concrete shall comply generally with the requirements given below. All precast units shall be cast on a suitable bed or platform with firm foundation and free from wind, The contractor shall be responsible for the accuracy of the level or shape of the bed or platform, A suitable serial number and the date of casting shall be impressed or painted on each unit. All precast concrete units shall be prepared and fixed as shown in the drawings and as specified in the detailed specification., Concrete mix shall be as specified or as shown in the drawings with machine mixed, machine vibrated and prepared by weigh batching with Contractor's own mix design which shall be approved by Consulting Engineers. IS: 456 Code Practice for Plain and Reinforced Concrete shall be followed as relevant Indian Standard Specification.
Precast Concrete. Inclusions
Precast Concrete. Precast xxxxx, slabs, channel edging and quadrants shall comply with the requirements of BS EN 1339:2003 and with the Drawings. Where the Contractor is permitted to carry out precasting on site, the precast units shall in addition to complying with the relevant BS, be manufactured in steel moulds on a vibrating table or as directed by the Engineer.
Precast Concrete. Materials: The preferred exterior materials shall be precast concrete or masonry. Precast concrete systems are acceptable construction materials. Precast systems shall be light in color, and consistent with the intentions of these guidelines. • Precast concrete shall be limited to integrally colored precast, painted or stained precast panels. • No raked concrete panels will be permitted. • Tilt-up concrete panels with accent bands will be permitted. • Tilt-slab concrete buildings shall have no greater than t2” exposed aggregate (which applies to all concrete surfaces), Tilt-slab construction walls may have no more than 300 SF of surface without reveals. Concrete color and aggregate shall be similar to samples as shown by Declarant or accepted in writing by the DRB. Applied stains and paint must be of a consistent architectural finish and maintained as required. Masonry Units Brick, Glazed Brick, Architectural CMU may be used as described below: • Masonry products shall include integrally colored split face units, painted or stained split face units or brick. No standard concrete units shall be permitted. • Glazed brick and glazed tile is for accent and fine details only. • Glass block would not be considered highlight brick and may be used as a masonry product at the owner’s discretion. • Concrete Masonry Units are an acceptable construction material when the masonry units have an architectural finish. Split face block is the suggested finish (fluted block is not an acceptable masonry unit). A smooth finished block is subject to DRB approval or may be used up to 10% of an accent block.
Precast Concrete. All external walls of the building shall have Precast component concrete panels up to the height specified on the drawings.
AutoNDA by SimpleDocs
Precast Concrete. Catch Basin (with cast iron frame and grated cover) (pricing includes supply and installation of catch basin, lid, etc. See Sections 1.1.3 and 1.1.4 for excavation, backfill, and compaction) (Note 3) C-0052, C-0061, C-0082 15 [**] [**] [**] 1.3.3.1 36" x 36" inside dimensions 10 each 15.00 [**] [**] [**] [**] [**] S

Related to Precast Concrete

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

  • Fuel 28.1 The Vehicle must be returned with the amount of fuel equal to that at the time of the commencement of the rental. If the Vehicle is returned with less fuel, the difference will be charged to You at a rate of $5.00 including GST per litre (which includes a service component).

  • Mergers, Acquisitions, Sales, etc The Borrower will not be a party to any merger or consolidation, or purchase or otherwise acquire all or substantially all of the assets or any stock of any class of, or any partnership or joint venture interest in, any other Person, or, sell, transfer, convey or lease all or any substantial part of its assets, or sell or assign with or without recourse any Loan, Contracts, Related Security or other Collateral or any interest therein (other than pursuant to and in accordance with the Transaction Documents).

  • Information Systems Acquisition Development and Maintenance Security of System Files. To protect City Information Processing Systems and system files containing information, Service Provider will ensure that access to source code is restricted to authorized users whose specific job function necessitates such access.

  • XXEREAS it is essential to Grey Wolf to retain and attract as directors and officers the most capable persons available;

  • Acquisition Services (i) Serve as the Company’s investment and financial advisor and provide relevant market research and economic and statistical data in connection with the Company’s assets and investment objectives and policies;

  • Electric If Customer has selected an Electricity Fixed Rate on the Application, Customer’s Price will be based on the Fixed Rate(s) which includes Local and State taxes, Gross Receipts Tax (GRT), PJM Adjustment (defined below) charges and adjustments and Utility applied charges and/or fees related to generation, plus the Administration Charge, which includes, Electricity Balancing Amount and third party utility and billing charges. Customer understands and agrees that included in the Administration Charge is the cost of the Energy Balancing Amount (defined below). Customer understands that in order for RITERATE ENERGY to be able to supply Energy to its existing and prospective customers, RITERATE ENERGY enters into supply arrangements to meet the forecasted consumption of its various groups of customers. These forecasts are based on historical data, load shapes and/or estimates. To the extent that actual pooled consumption of RITERATE ENERGY’s Energy customers varies from supply arrangements and/or Customer’s Utility delivery requirements, RITERATE ENERGY incurs a cost in balancing and settling its supply arrangements with such pooled consumption. To ensure a fixed all-inclusive Rate, RITERATE ENERGY has included in the Administration charge, the Energy Balancing Amount, to balance and settle the variance between pooled consumption and supply arrangements (the “Energy Balancing Amount”). In respect of Electricity, Customer understands that there are certain estimated pass through costs, made up of charges to RITERATE ENERGY by the PJM Interconnection (“PJM”) and/or Customer’s Utility, including but not limited to ancillary service charges, the cost of unaccounted for electricity, capacity charges and any replacement or recharacterization of these charges. In this regard, the “PJM Adjustment”, is included in the Fixed Price Rate. Customer acknowledges and agrees that by entering into this Agreement, Customer will not be eligible to receive any net metering credits and other incentives to which Customer would otherwise be entitled. Further, included in the Rate are the amounts charged or billed to RITERATE ENERGY or Customer by Customer’s Utility, the PUC or any other regulatory or government entity, including any taxes, delivery, regulated transmission, regulated distribution, pipeline, compressor fuel, uplift, congestion, locational marginal pricing, invoice market participant, service, billing, or similar or related changes and any, deposits, interest or late payment fees or other amounts in connection with the supply and delivery of Energy to the Premises (collectively, “Regulatory Charges”). Customer agrees to pay the monthly Administration charge for Energy supply (the “Administration” charge).

  • Engineering Services Definition: Engineering Services includes any service or creative work, the adequate performance of which requires education, training and experience in the application of special knowledge in consulting, investigating, evaluating, planning and designing, engineering principles. Engineering Services covered by the Xxxxxx Architect-Engineers Act (40 U.S.C. 1102) are not covered in the primary scope of OASIS SB. Examples: Service areas that are included under the Engineering Services discipline include, but are not limited to the following:

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

Time is Money Join Law Insider Premium to draft better contracts faster.