Power System Particulars; Sample Clauses

Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: Normal Voltage 415V 11KV 33KV Maximum Voltage 500V 12 KV 36KV No. Of phases 3 3 3 System frequency (Hz) 50 50 50 No. of wires 5 3 3 Fault level (MVA) 25 350 1500 Fault Current / Duration * * 25 kA / 3s Earth Fault Current / Duration * 3 kA / 3 s 3 kA / 3 s Neutral point Earthing Solid Resistance Resistance Conductor arrangement Vertical Horizontal Horizontal
AutoNDA by SimpleDocs
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: Table 6 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV 3 No. Of phases 3 3 3 4 System frequency (Hz) 50 50 50 5 No. of wires 5 3 3 6 Fault level (MVA) 25 350 1500 7 Fault Current / Duration * * 25 kA / 3s 8 Earth Fault Current / Duration * 3 kA / 3s 3 kA / 3s 9 Neutral point Earthing Solid Resistance Resistance 10 Conductor arrangement Vertical Horizontal Horizontal
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV 3 No. Of phases 3 3 3 4 System frequency (Hz) 50 50 50 5 No. of wires 5 3 3 6 Fault level (MVA) 25 350 1500 7 Fault Current / Duration 120KA/3S * 25 kA / 3s 8 Earth Fault Current / Duration * 3 kA / 3s 3 kA / 3s 9 Neutral point Earthing Solid Resistance Resistance 10 Conductor arrangement Vertical Horizontal Horizontal ⮚ Technical Specifications for Item no.1: Rated 36 KV, Single Core Cable, Aluminum Conductor of 400 mm2, XLPE Insulated, Copper Wire Screened, Aluminum Wire Armored, And PVC Sheath. ◼ As per the details
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data:

Related to Power System Particulars;

  • Network Resource Interconnection Service (check if selected)

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • PROPANE GAS SYSTEM SERVICE AREA If the Property is located in a propane gas system service area owned by a distribution system retailer, Seller must give Buyer written notice as required by §141.010, Texas Utilities Code. An addendum containing the notice approved by TREC or required by the parties should be used.

  • Interconnection Service Interconnection Service allows the Interconnection Customer to connect the Large Generating Facility to the Participating TO’s Transmission System and be eligible to deliver the Large Generating Facility’s output using the available capacity of the CAISO Controlled Grid. To the extent the Interconnection Customer wants to receive Interconnection Service, the Participating TO shall construct facilities identified in Appendices A and C that the Participating TO is responsible to construct. Interconnection Service does not necessarily provide the Interconnection Customer with the capability to physically deliver the output of its Large Generating Facility to any particular load on the CAISO Controlled Grid without incurring congestion costs. In the event of transmission constraints on the CAISO Controlled Grid, the Interconnection Customer's Large Generating Facility shall be subject to the applicable congestion management procedures in the CAISO Tariff in the same manner as all other resources.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5.1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service to Interconnection Customer at the Point of Interconnection.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Uncovering and Correction of Work 12 Uncovering of Work 12.1 Unforeseen Conditions, Concealed or Unknown 3.7.4, 8.3.1, 10.3 Unit Prices 7.3.3.2, 9.1.2

  • Developer Attachment Facilities Developer shall design, procure, construct, install, own and/or control the Developer Attachment Facilities described in Appendix A hereto, at its sole expense.