Partitions Sample Clauses

Partitions. In order to ensure maximum privacy for clients and to preserve the attorney-client privilege, the Employer agrees to construct floor to ceiling partitions for the offices of all casehandling staff where architecturally feasible. The feasibility of such construction may be limited by the cost relating to lighting and airflow.
AutoNDA by SimpleDocs
Partitions. (a) Partitions within the Premises shall have 2” gypsum board on each sided of 3-5/8” metal studs, 16’ on center, taped and spackled. Partitions between the Premises, corridor(s) and between the Premises and adjacent space, shall have 5/8” fire code gypsum board, taped and spackled, on each side of 3-5/8” metal studs, 16” on center above finished ceiling to underside of metal deck. Demising partitions and corridor partitions to have thermofibre insulation installed within, and to be constructed from floor to underside of metal deck above.
Partitions. 1. Interior partitions will be constructed of 2 1/2" metal studs at 24" on center, from floor slab to the underside of the finished ceiling, with 1/2" gypsum wallboard panels with taped and finished joints prepared for paint.
Partitions. One (1) linear foot of ceiling height partition per twelve (12) square feet of Net Rentable Area less Common Areas. All required partitions shall be 5/8" gypsum board, painted with two coats of latex on 2-1/2" metal studs at 24" on center, with 2-1/2" base.
Partitions. 1.1 DEMISING WALL - ONE HOUR FIRE RESISTIVE CONSTRUCTION
Partitions. PERMANENT (APR 2015)‌ Permanent partitions shall extend from the structural floor slab to the structural ceiling slab. They shall be provided by the Lessor as part of shell rent as necessary to surround the Space, stairs, corridors, elevator shafts, restrooms, all columns, and janitor closets. They shall have a flame spread rating of 25 or less and a smoke development rating of 450 or less (ASTM E-84). Stairs, elevators, and other floor openings shall be enclosed by partitions and shall have the fire resistance required by the applicable building code, fire code and ordinances adopted by the jurisdiction in which the Building is located (such as the International Building Code, etc.) current as of the Lease Award Date. Newly installed gypsum board material must be Greenguard Gold Certified or have 0 grams per liter of VOCs.
Partitions. Landlord will provide Interior Demising Partitions and Perimeter Demising Partitions. At Landlord's option, the demising partitions shall be of unfinished (i) masonry, or (ii) concrete, or (iii) metal or wood studs sixteen inches (16") on center, to the underside of the structure above. Where such partitions fall on structural column lines, at structural braces or structural expansion joints, projections may occur. Where desirable in Landlord's opinion, a vertical neutral strip will be located at the storefront area between stores.
AutoNDA by SimpleDocs
Partitions a. All existing walls are to remain other than shown on attached plan.
Partitions. Construct interior partition walls per Plan, site conditions permitting. Interior partition walls to be constructed of metal studs, 5/8" sheetrock. Interior partition walls to be constructed up to the underside of the hung ceiling, except for all offices which shall extend no less than 6 inches above the ceiling.
Partitions. Scar patch and finish wall ends where storage room was removed to enlarge the existing breakroom and add a single exit door utilizing building standard components.