Overhead Doors Sample Clauses

Overhead Doors. All overhead doors shall remain closed unless ingress or egress is in progress, except between the hours of 9:00 a.m. and 4:00 p.m. Monday through Saturday. R
AutoNDA by SimpleDocs
Overhead Doors. The Contractor shall develop and implement a PM program for overhead doors and associated equipment to ensure proper operation, to minimize breakdowns, and to maximize useful life. The PM program shall provide an economical approach, manufacturers’ recommended procedures, OEM standards, and maintenance required to satisfy equipment warranties and keep overhead doors in normal working condition. As part of the PM, fire doors shall be tested in accordance with UFC 3-601-02. Testing results shall be documented on the PM report. Replacement of fusible links, if required, shall be included as part of the PM. The overhead door inventories are provided in J-1502000-07. Maintenance is accomplished in accordance with the Contractor’s PM program and work schedule. PM is performed in accordance with manufacturers’ recommended procedures and OEM standards.
Overhead Doors. 8.4.1 One (1) 10 x 12 overhead door - manual.
Overhead Doors. Except where noted otherwise, overhead doors, including truck dock doors, shall be manufacturer’s standard sectional steel doors, roll-formed, assembled from individual steel panels with weather tight joints. Provide vertical lift where possible, otherwise high lift. Strength of door, including gauge, profile and reinforcement, shall permit smooth operation while subject to expected wind loads in the area. Nominal thickness 2”, thicker if required for strength. Face sheet shall be minimum 29 gauge hot-dipped galvanized steel, stronger if required for strength. End and center xxxxxx shall be minimum 16 gauge galvanized steel, stronger if required for strength. Provide factory baked-on polyester or epoxy prime paint, or approved equal, and finish paint in field. Maximum permitted deflection is 1/120 of door width. Provide slide locks on both jambs. Provide handles on inside of manually operated doors at both sides and middle. Provide rigid foot plate on both sides to assist with slide lock operation. Provide manufacturer’s standard sealed vision panels, except where required to be fire-rated. Provide weather-stripping seals for jambs and head. Floor seal shall be flexible EPDM rubber bulb. Jamb shall be minimum 16-gauge steel. Exterior doors and doors between heated and unheated or air conditioned and non-air-conditioned spaces, as applicable, shall be insulated and provided with 29-gauge backer sheet.
Overhead Doors. Lessee may, at Lessee's expense, modify (to enlarge) the overhead doors on the west side of the Building, as shown on Exhibit "A".
Overhead Doors. A. (146) - 8'x10' and (4) - 14'x16' overhead doors have been provided.
Overhead Doors. Match the existing building overhead doors. If no O.H. doors exist, use Overhead Door Company or equal with 3" track 20 gauge door vertical reinforced bottom rail, with step plate flush panel sectional. Saw a licensed structural engineer must certify cutting at exterior concrete panels. No overcuts will be allowed.
AutoNDA by SimpleDocs
Overhead Doors. A. Provide metal high lift sectional doors with insulation inserts and metal covers.
Overhead Doors. 4.1.1 Overhead Coiling Doors
Overhead Doors. 8G-01 Provide two (2) manually operated, 8’ x 9’, insulated overhead doors. DIVISION 9 FINISHES SECTION 9 A - RESILIENT BASE 9A-01 Resilient base shall be 4” high vinyl cove or straight as applicable.