Membrane Configuration Sample Clauses

Membrane Configuration. Each stream has four independent banks of membranes fed from a common header running the length of the stream. This arrangement allows a bank to be isolated with the stream operating, so that membrane cleaning or maintenance can be carried out with no loss of water production (assuming the Standby Bank is operating). Each individual bank is further divided into two half banks, each of which can be isolated from the main stream. Each half bank has three feed, reject and product risers, with the capacity for 22 pressure vessels per riser, making a maximum capacity of membranes per stream of 528. The initial design value was 448 membranes per stream. The membranes were of the hollow fine fibre type, Du Pont Model B10 6840T, each housed in a single fibreglass pressure vessel. Figure 9 shows one of the first pass streams from the feed / brine side. An extensive on-line monitoring system is provided for measuring a total of 192 membrane differential pressures, one membrane per riser and each of the half bank product conductivities is also monitored. Provision was made for extensive manual differential pressure measurement to supplement the on-line measurements when required. This system is one quarter the capacity of each of the main streams and is equivalent to one bank (4 banks per stream) of the main first pass streams. It’s purpose is to operate during the cleaning of one of main streams, which is done on a bank by bank basis, so that the full plant’s capacity can be maintained.‌‌ The configuration is very similar to the first pass main streams, except that there is no energy recovery turbine, no equivalent second pass system and the product water is fed directly to the drawback tanks.
AutoNDA by SimpleDocs

Related to Membrane Configuration

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Functionality Customer is entitled to additional functionality previously purchased or bundled with the software if available in the version or update released on or after the start date of the Agreement. Customer acknowledges that certain functionality in current and previous software versions may not be available in future upgrades. Added functionality may require additional paid services (clinical and technical) to configure and support.

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • Software Use Case Red Hat Enterprise Virtualization Supported on physical hardware solely to support virtual quests. Red Hat Enterprise Virtualization is designed to run and manage virtual instances and does not support user-space applications. Red Hat Enterprise Virtualization may be used as a virtual desktop infrastructure solution, however, the Subscription does not come with any software or support for the desktop operating system. You must purchase the operating system for each instance of a desktop or server separately.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Upgrade 5.1 Every version of the Software is treated as a separate product and comes under its own End-User License Agreement. By installing any other version of the Software, which is licensed under the terms of this XXXX, the Licensee terminates this Agreement according to clause 4.1.3 and enters into another End-User License Agreement that comes with the installed version.

  • Architecture The Private Improvements shall have architectural features, detailing, and design elements in accordance with the Project Schematic Drawings. All accessory screening walls or fences, if necessary, shall use similar primary material, color, and detailing as on the Private Improvements.

  • Server Software Subject to the terms and conditions of this XXXX, Vocera grants you the non-exclusive right to (i) install and run (“Use”) the Server Software on computer systems (each, a “Server Computer”) located at End User’s Facilities in the geographic territory designated above (“Territory”); (ii) to Use the Client Software in conjunction with Authorized Client Devices and such Server Computers; and (iii) for pilot licenses for certain Software provided on a trial basis, use such Software for the limited term specified by Vocera in writing. You may Use the standard Server Software on one primary Server Computer (or a primary cluster of computers suitably configured for productive use of the Server Software). You may install backup copies of the Server Software on backup Server Computers to provide redundancy in the event of failure of the primary Server Computer(s) but, unless you have acquired additional licenses or a failover license from Vocera, you may not run such backup or additional copies concurrently with the primary copies. Vocera grants you the right to use the applicable License Key issued by Vocera only to enable Use of the Server Software in conjunction with the licensed Server Computers. Server Software may be licensed for a Subscription Term as specified in the Quote.

  • Signaling Parameters All SS7 signaling parameters will be provided in conjunction with traffic exchange trunk groups, where and as available. These parameters include Automatic Number Identification ("ANI"), Calling Party Number ("CPN"), Privacy Indicator, calling party category information, originating line information, charge number, etc. Also included are all parameters relating to network signaling information, such as Carrier Information Parameter ("CIP"), wherever such information is needed for call routing or billing. GTE will provide SS7 via GR-394-SS7 and/or GR-317-SS7 format(s).

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

Time is Money Join Law Insider Premium to draft better contracts faster.